- OS800D30P
The ABB OS800D30P is a three-pole fuse protector with a rated current of 800 A in the main circuit and a rated operational voltage of 690 V AC. It is a front-operated, base-mounted device with lug terminals and a pistol handle and shaft included. Fuse size is NH3 in the DIN system. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed conventional thermal current is 720 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It conforms to IEC 60947-3. Net dimensions are 343 mm wide, 306 mm high, and 233 mm deep, with a net weight of 14.89 kg.
- OS800D31F
ABB fuse protector, model OS800D31F, manufacturer ID 1SCA022834R6810. Four-pole front-operated fuse switch disconnector for base mounting, with switched-fusible fourth pole and NH3 DIN fuse system. Rated current 800 A; conventional free-air thermal current 800 A at 40 °C; fully enclosed thermal current 720 A. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Lug terminals, 39 mm wide, tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions 429 x 306 x 233 mm; net weight 19.154 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OS800D31N2
ABB OS800D31N2 fuse switch disconnector, 4-pole, front-operated, base mounting, with the fourth pole on the right side switched with a solid link. It accepts NH3 DIN fuses. Rated current is 800 A in the main circuit; conventional free-air thermal current is 800 A at 40 °C, and conventional thermal current fully enclosed is 720 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. Power loss is 75 W per pole at rated operating conditions. Dimensions are 429 mm wide, 306 mm high, and 233 mm deep; net weight 18.54 kg. Standards: IEC 60947-3. Handle and shaft are not included.
- OS800D3LAA3B
ABB fuse protector, display model OS800D3LAA3B, manufacturer ID 1SCA022325R4930. This is a three-pole DIN fuse system unit for fuse size 3, with a pistol-type black handle. It accepts cable cross-sections of 240 mm², with cable entry from above or below and open cable outlets per side. Rated conventional thermal current (Ithe) is 570 A fully enclosed. The steel sheet enclosure provides protection according to IEC 60529 IP54 at pollution degree 3. Dimensions are 800 mm wide, 1000 mm high, and 330 mm deep; net weight is 59.455 kg (131.08 lb). Up to 2 NO and 1 NC auxiliary contacts can be mounted; none are mounted as supplied.
- OS800D40F
ABB OS800D40F fuse switch disconnector, four-pole, front-operated, base mounting. Main circuit rated 690 V AC, 800 A, with rated insulation voltage 1000 V and rated impulse withstand voltage 12 kV. Conventional free-air thermal current 800 A at 40 °C; fully enclosed conventional thermal current 720 A. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Fuse size NH3, DIN fuse system; fourth pole switched-fusible. Lug terminals, 39 mm terminal width, tightening torque 50 to 75 N·m. Power loss 75 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Dimensions 429 mm wide, 306 mm high, 233 mm deep; net weight 19.154 kg.
- OS800D40FP
The ABB OS800D40FP is a four-pole fuse switch disconnector with a switched-fusible fourth pole, rated 800 A in the main circuit and 720 A fully enclosed. It accepts NH3 DIN fuses and is front operated via a pistol handle and shaft, with base mounting and lug terminals. Rated insulation voltage is 1000 V, rated operational voltage 690 V AC, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. Conventional free-air thermal current is 800 A at 40 °C. It conforms to IEC 60947-3. Dimensions are 429 mm wide, 306 mm high, and 233 mm deep; net weight is 19.654 kg.
- OS800D40N1
ABB OS800D40N1 fuse switch disconnector, 4-pole, front-operated, base mounting. Rated current 800 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 800 A at 40 °C; fully enclosed conventional thermal current 720 A. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Accepts NH3 DIN fuse links. Line terminals top in, bottom out or bottom in, top out. Lug terminals, 39 mm width, tightening torque 50 to 75 N·m. Fourth pole switched with solid link, left side. Dimensions 429 x 306 x 233 mm; net weight 18.54 kg. Pollution degree 3. IEC 60947-3. Handle and shaft not included.
- OS800D40N2
ABB OS800D40N2 is a four-pole fuse protector for base mounting, front operated, with NH3 DIN fuse size and lug terminals 39 mm wide. Main circuit rated current is 800 A at 690 V AC; conventional free-air thermal current is 800 A at 40 °C, and fully enclosed conventional thermal current is 720 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. Rated short-time withstand current is 18 kA rms for 1 s. Power loss is 75 W per pole at rated operating conditions. Tightening torque is 50 to 75 N·m. Dimensions are 429 mm wide, 306 mm high, and 233 mm deep; net weight is 18.54 kg. Standards: IEC 60947-3. Handle and shaft are not included.