- OS800D13F
The ABB OS800D13F is a four-pole fuse protector with base mounting, front operation, and lug terminals. It is rated 800 A in the main circuit, with conventional free-air thermal current 800 A at 40 °C and conventional thermal current 720 A fully enclosed. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. Fuse size is NH3, DIN system, with a switched fusible fourth pole. Power loss is 75 W per pole at rated operating conditions. Terminal width is 39 mm and tightening torque is 50 to 75 N·m. Pollution degree is 3. Standards: IEC 60947-3. Handle and shaft are not included.
- OS800D13N2
ABB OS800D13N2 fuse protector, manufacturer ID 1SCA022834R4790. Four-pole, front-operated fuse switch disconnector for NH3 DIN fuses, base mounting, with the fourth pole on the right side, switched with solid link. Rated current 800 A; conventional free-air thermal current 800 A at 40 °C; conventional thermal current 720 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 18 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Dimensions 429 x 306 x 233 mm; net weight 18.54 kg. Lug terminals, 39 mm wide, tightening torque 50 to 75 N·m. Pollution degree 3. Conforms to IEC 60947-3. Handle and shaft not included.
- OS800D13N2K
The ABB OS800D13N2K is a 4-pole fuse protector with a front-operated, base-mounted design and a direct-mounted handle. It uses NH3 fuses in the DIN fuse system, with the fourth pole on the right side, switched with a solid link. The main circuit is rated 800 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed thermal current is 720 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 18 kA rms for 1 s. It conforms to IEC 60947-3. Dimensions are 289 mm wide, 429 mm high, and 306 mm deep; net weight is 19.4 kg.
- OS800D13N2P
The ABB OS800D13N2P is a four-pole fuse protector with a main circuit rated current of 800 A and a rated operational voltage of 690 V AC. It uses NH3 DIN fuses and is front operated via a pistol handle and shaft, with base mounting. The fourth pole is switched with a solid link and positioned on the right side. Terminal type is lug terminals, 39 mm wide, with tightening torque of 50 to 75 N·m. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed thermal current is 720 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. It conforms to IEC 60947-3.
- OS800D20
The ABB OS800D20 is a 2-pole fuse switch disconnector with front operation and base mounting. It accepts NH2 and NH3 fuses in a DIN fuse system and uses lug terminals with a tightening torque of 50 to 75 N·m. The main circuit is rated 690 V AC, and power loss is 75 W per pole at rated operating conditions. Dimensions are 233 mm wide, 255 mm high, and 306 mm deep, with a net weight of 10.1 kg. The device is classified under IEC 60947-3. The manufacturer ID is 1SCA139869R1001. It falls under WEEE Category 5, small equipment with no external dimension more than 50 cm.
- OS800D21
ABB OS800D21 fuse switch disconnector, 3-pole, front-operated, base mounting. Rated current 800 A; conventional free-air thermal current 800 A at 40 °C; fully enclosed thermal current 720 A. Rated operational voltage 690 V AC. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, pollution degree 3. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Accepts NH3 DIN fuse system fuses. Lug terminals, 39 mm terminal width, tightening torque 50 to 75 N·m. Line terminals top in/bottom out or bottom in/top out. Power loss 75 W per pole at rated operating conditions. Standards: IEC 60947-3. Dimensions 341 mm width, 306 mm height, 233 mm depth; net weight 14.39 kg. Handle and shaft not included.
- OS800D22F
The ABB OS800D22F is a four-pole fuse protector with base mounting and front operation. It accepts NH3 fuses in the DIN system. The main circuit is rated 800 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed conventional thermal current is 720 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. Power loss is 75 W per pole at rated operating conditions. Dimensions are 429 mm wide, 306 mm high, and 233 mm deep; net weight is 19.154 kg. Lug terminals are 39 mm wide, tightened to 50 to 75 N·m. Standards: IEC 60947-3. Handle and shaft are not included.
- OS800D22FP
The ABB OS800D22FP is a four-pole fuse protector with a switched-fusible fourth pole, base mounting, and front operation via an included pistol handle and shaft. It accepts NH3 DIN fuses and uses lug terminals 39 mm wide, tightened to 50 to 75 N·m. The main circuit is rated 800 A at 690 V AC, with conventional free-air thermal current 800 A at 40 °C and enclosed thermal current 720 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. It conforms to IEC 60947-3. Net dimensions are 429 mm wide, 306 mm high, and 233 mm deep; net weight is 19.654 kg.