- OS630D13N2-60
The ABB OS630D13N2-60 is a four-pole fuse switch disconnector for base mounting with front operation. It accepts NH2 and NH3 fuses in the DIN system and uses lug terminals. The main circuit is rated 690 V AC, and power loss is 46 W per pole at rated operating conditions. Terminal tightening torque is 50 to 75 N·m. The unit weighs 17.33 kg and is classified under IEC 60947-3. ETIM 8 and ETIM 9 classification is EC001040, Fuse switch disconnector. Manufacturer ID: 1SCA110994R1001.
- OS630D13N2K
The ABB OS630D13N2K is a 4-pole front-operated fuse switch disconnector for base mounting, with a direct-mounted handle and a switched fourth pole on the right side using a solid link. It accepts NH3 DIN fuses and lug terminals 39 mm wide, tightened to 50 ... 75 N·m. Rated values include 630 A main circuit, 690 V AC, 1000 V insulation, 12 kV impulse withstand, and 80 kA conditional short-circuit current at 690 V. Conventional free-air thermal current is 630 A at 40 °C; enclosed thermal current is 570 A. Power loss is 46 W per pole at rated operating conditions. It conforms to IEC 60947-3. Dimensions are 279 mm wide, 429 mm high, and 306 mm deep; weight is 19.4 kg.
- OS630D13N2P
The ABB OS630D13N2P is a fuse protector with a DIN NH3 fuse system and a switched fourth pole on the right side using a solid link. It measures 429 mm wide, 306 mm high, and 233 mm deep, weighing 15.9 kg. Conventional free-air thermal current is 630 A at 40 °C; fully enclosed conventional thermal current is 570 A. Pollution degree 3. A pistol handle and shaft are included.
- OS630D21
ABB OS630D21 fuse switch disconnector, 3-pole, front-operated, base mounting. Main circuit rated 690 V AC, 630 A, with rated insulation voltage 1000 V and rated impulse withstand voltage 12 kV. Conventional free-air thermal current 630 A at 40 °C; fully enclosed thermal current 570 A. Rated conditional short-circuit current 80 kA at 690 V, and rated short-time withstand current 18 kA rms for 1 s. Accepts NH3 DIN fuse system fuses. Lug terminals, 39 mm terminal width, tightening torque 50 to 75 N·m. Power loss 46 W per pole at rated operating conditions. Pollution degree 3. Dimensions 341 mm wide, 306 mm high, 233 mm deep; net weight 14.39 kg. Conforms to IEC 60947-3. Handle and shaft not included.
- OS630D21P
ABB fuse protector, model OS630D21P, manufacturer ID 1SCA022835R7930. Three-pole, front-operated fuse switch disconnector for NH3 DIN fuses, base mounting, with pistol handle and shaft included. Rated current 630 A in the main circuit; conventional free-air thermal current 630 A at 40 °C, 570 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Power loss 46 W per pole at rated operating conditions. Lug terminals, 39 mm wide, tightening torque 50 to 75 N·m. Dimensions 341 mm wide, 306 mm high, 233 mm deep; net weight 14.89 kg. Pollution degree 3. Conforms to IEC 60947-3.
- OS630D22F
ABB OS630D22F fuse switch disconnector, 4-pole, base mounting, front operated. Rated current 630 A at 690 V AC; conventional free-air thermal current 630 A at 40 °C, fully enclosed 570 A. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 18 kA rms for 1 s. Fuse size NH3, DIN fuse system; fourth pole switched-fusible. Power loss 46 W per pole at rated operating conditions. Lug terminals, 39 mm terminal width, tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions 429 x 306 x 233 mm; net weight 19.154 kg. Handle and shaft not included. Conforms to IEC 60947-3.
- OS630D22F-60
ABB OS630D22F-60 fuse protector, manufacturer ID 1SCA124535R1001. Four-pole, front-operated fuse switch disconnector for base mounting, accepting NH2 and NH3 fuses in the DIN fuse system. Rated operational voltage is 690 V AC for the main circuit. Power loss is 46 W per pole at rated operating conditions. Lug terminals accept a tightening torque of 50 to 75 N·m. The unit weighs 17.16 kg and conforms to IEC 60947-3. ETIM 8 and ETIM 9 classify it as EC001040, fuse switch disconnector. WEEE Category 5, small equipment with no external dimension more than 50 cm.
- OS630D22N1
ABB OS630D22N1 fuse protector, a four-pole front-operated fuse switch disconnector for base mounting. Main circuit rated 690 V AC and 630 A; conventional free-air thermal current 630 A at 40 °C, fully enclosed thermal current 570 A. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V, and short-time withstand current 18 kA rms for 1 s. Fuse system DIN, fuse size NH3. Fourth pole is switched with solid link, left side. Power loss 46 W per pole at rated operating conditions. Lug terminals, 39 mm wide, tightening torque 50 to 75 N·m. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Net dimensions 429 x 306 x 233 mm; net weight 18.54 kg.