- OS630D22N1P
The ABB OS630D22N1P is a four-pole, front-operated fuse switch disconnector for base mounting. It uses NH3 fuses in the DIN system and accepts lug terminals 39 mm wide, tightened to 50 to 75 N·m. The fourth pole, on the left side, is switched with a solid link. Rated current of the main circuit is 630 A, with conventional thermal current of 630 A at 40 °C free air and 570 A fully enclosed. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 18 kA rms for 1 s. Pollution degree 3. It conforms to IEC 60947-3. Dimensions are 429 mm wide, 306 mm high, and 233 mm deep; net weight is 19.04 kg. A pistol handle and shaft are included.
- OS630D22N2-60
ABB fuse protector, model OS630D22N2-60, manufacturer ID 1SCA022864R9550. Four-pole fuse switch disconnector for base mounting, front operated, accepting NH2 and NH3 fuses in a DIN fuse system. Rated operational voltage of the main circuit is 690 V AC. Power loss is 46 W per pole at rated operating conditions. Lug terminals are provided; tightening torque is 50 to 75 N·m. Dimensions are 453 mm width, 328 mm height, and 260 mm depth, with a net weight of 17.33 kg. The device is classified under IEC 60947-3. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector. WEEE category 5 covers small equipment with no external dimension more than 50 cm.
- OS630D22N2K
The ABB OS630D22N2K is a front-operated, four-pole fuse switch disconnector with base mounting and a direct mounted handle. It accepts NH3 fuses in the DIN fuse system. The main circuit is rated 630 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 630 A at 40 °C; fully enclosed conventional thermal current is 570 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. The fourth pole, on the right side, is switched with a solid link. Cable cross-section is 2.5 to 25 mm²; tightening torque is 50 to 75 N·m. Standards: IEC 60947-3.
- OS630D30P
The ABB OS630D30P is a front-operated, 3-pole fuse switch disconnector for base mounting, using NH3 DIN fuse links. It is rated 630 A in the main circuit at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 630 A at 40 °C; fully enclosed conventional thermal current is 570 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 18 kA rms for 1 s. It conforms to IEC 60947-3. Dimensions are 343 mm wide, 306 mm high, and 233 mm deep, weighing 14.89 kg. Lug terminals accept 50 to 75 N·m tightening torque. A pistol handle and shaft are included.
- OS630D31F
ABB OS630D31F fuse switch disconnector, 4-pole, front-operated, base mounting. Rated current 630 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV; rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Conventional free-air thermal current 630 A at 40 °C; enclosed thermal current 570 A. Fuse size NH3, DIN fuse system. Fourth pole switched-fusible. Power loss 46 W per pole at rated operating conditions. Lug terminals, 39 mm width, tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions 429 x 306 x 233 mm; net weight 19.154 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OS630D31N2
ABB OS630D31N2 is a four-pole fuse switch disconnector for base mounting, front operated, with the fourth pole on the right side as a switched pole with solid link. It accepts NH3 DIN fuses. Rated current of the main circuit is 630 A, with conventional free-air thermal current 630 A at 40 °C and conventional thermal current 570 A fully enclosed. Rated operational voltage is 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 18 kA rms for 1 s. Power loss is 46 W per pole at rated operating conditions. Dimensions are 429 mm width, 306 mm height, 233 mm depth; net weight 18.54 kg. Lug terminals, 39 mm wide, tighten to 50 to 75 N·m. Standards: IEC 60947-3. Handle and shaft not included.
- OS630D40N2
The ABB OS630D40N2 is a four-pole fuse switch disconnector for base mounting, with front operation and a switched fourth pole on the right side using a solid link. It accepts NH3 DIN fuses and uses lug terminals 39 mm wide, tightened to 50 to 75 N·m. Rated current is 630 A in the main circuit; conventional free-air thermal current is 630 A at 40 °C, and fully enclosed thermal current is 570 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 18 kA rms for 1 s. Power loss is 46 W per pole at rated operating conditions. It conforms to IEC 60947-3. Handle and shaft are not included.
- OS630DS03
ABB OS630DS03 is a 3-pole fuse protector, manufacturer ID 1SCA108128R1001. It is side operated with base mounting and accepts NH3 DIN fuses. Main circuit rated current is 630 A. Conventional free-air thermal current is 630 A at 40 °C; conventional thermal current fully enclosed is 570 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. Power loss is 46 W per pole at rated operating conditions. Line terminals may be top in/bottom out or bottom in/top out. Pollution degree is 3. Dimensions are 414 mm wide, 306 mm high, and 247 mm deep; net weight is 13.9 kg. Handle and shaft are not included.