- AX25-30-10-88
The ABB AX25-30-10-88 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 25 A at 380/400 V and 415 V, and 10 A at 690 V, at 55 °C. Rated operational power AC-3 is 11 kW at 380/400 V and 415 V. The coil is rated 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Dimensions are 44 mm wide, 74 mm deep, and 76.3 mm high; net weight is 0.326 kg. Terminals are screw type, IP20. Maximum operating altitude without derating is 3000 m.
- AX260-30-11-80
ABB AX260-30-11-80 AC contactor, manufacturer ID 1SFL547074R8011. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, and 250 A at 500 V and 690 V, all at 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, 160 kW at 440 V and 500 V, 200 kW at 690 V, and 75 kW at 220/230/240 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; weight 4.7 kg.
- AX260-30-11-81
The ABB AX260-30-11-81 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 4.7 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C, and 250 A at 500 V and 690 V at 55 °C. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 8 kV.
- AX260-30-11-83
The ABB AX260-30-11-83 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 4.7 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V. Maximum electrical switching frequency is 300 cycles per hour. Rated impulse withstand voltage is 8 kV.
- AX260-30-11-84
The ABB AX260-30-11-84 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Its main circuit is rated 1000 V at 60 Hz, with a rated insulation voltage of 690 V and rated impulse withstand voltage of 8 kV. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V. The contactor measures 140 mm wide, 180 mm deep, and 225 mm high, weighs 4.7 kg, and has main circuit bar terminals.
- AX260-30-11-85
The ABB AX260-30-11-85 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 60 Hz, with a conventional free-air thermal current of 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 8 kV. Mechanical durability is 5 million operations. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 4.7 kg. Main circuit terminals are bars.
- AX260-30-11-86
The ABB AX260-30-11-86 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 4.7 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V, 440 V, and 220/230/240 V, 250 A at 500 V and 690 V, all at 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, 160 kW at 440 V and 500 V, 200 kW at 690 V, and 75 kW at 220/230/240 V. Maximum electrical switching frequency is 300 cycles per hour.
- AX260-30-11-88
The ABB AX260-30-11-88 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 220/230/240 V, 380/400 V, 415 V, and 440 V at 55 °C, and 250 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 includes 132 kW at 380/400 V and 415 V, 160 kW at 440 V and 500 V, and 200 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; weight 4.7 kg.