- AX260-30-11-85
The ABB AX260-30-11-85 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 60 Hz, with a conventional free-air thermal current of 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 8 kV. Mechanical durability is 5 million operations. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 4.7 kg. Main circuit terminals are bars.
- AX260-30-11-86
The ABB AX260-30-11-86 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 4.7 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V, 440 V, and 220/230/240 V, 250 A at 500 V and 690 V, all at 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, 160 kW at 440 V and 500 V, 200 kW at 690 V, and 75 kW at 220/230/240 V. Maximum electrical switching frequency is 300 cycles per hour.
- AX260-30-11-88
The ABB AX260-30-11-88 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 220/230/240 V, 380/400 V, 415 V, and 440 V at 55 °C, and 250 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 includes 132 kW at 380/400 V and 415 V, 160 kW at 440 V and 500 V, and 200 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; weight 4.7 kg.
- AX300-30-11-80
ABB AX300-30-11-80 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 220/230/240 V, 380/400 V, 415 V, and 440 V at 55 °C, and 290 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 includes 90 kW at 220/230/240 V and 160 kW at 380/400 V, 415 V, and 440 V. Maximum electrical switching frequency is 300 cycles per hour. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight 4.7 kg.
- AX300-30-11-81
ABB AX300-30-11-81 AC contactor, manufacturer ID 1SFL587074R8111. Main circuit rated 1000 V at 50 Hz, with three normally open main contacts and one NO plus one NC auxiliary contact. Rated operational current AC-3 is 305 A at 415 V, 55 °C, and rated operational power AC-3 is 160 kW at 415 V. Rated breaking capacity AC-3 is 8 x Ie and making capacity is 10 x Ie. Conventional free-air thermal current Ith is 250 A per IEC 60947-4-1 at 40 °C. Coil voltage is 24 V at 50 Hz and 60 Hz. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight 4.7 kg.
- AX300-30-11-83
The ABB AX300-30-11-83 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 250 A at 40 °C for open contactors. AC-1 ratings at 690 V are 500 A at 40 °C, 400 A at 55 °C, and 325 A at 70 °C. AC-3 ratings at 55 °C include 305 A at 415 V and 290 A at 690 V, with rated operational power up to 250 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 4.7 kg.
- AX300-30-11-84
ABB AX300-30-11-84 AC contactor, manufacturer ID 1SFL587074R8411. Three normally open main contacts, one normally open and one normally closed auxiliary contact. Main circuit rated operational voltage 1000 V at 60 Hz. Conventional free-air thermal current per IEC 60947-4-1, open contactors at 40 °C ambient: 250 A. Rated operational current AC-3: 305 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C; 290 A at 500 V and 690 V at 55 °C. Rated operational power AC-3: 160 kW at 415 V, 440 V, and 380/400 V; 200 kW at 500 V; 250 kW at 690 V; 90 kW at 220/230/240 V. Rated insulation voltage 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage 8 kV. Maximum electrical switching frequency 300 cycles per hour. Dimensions 140 x 180 x 225 mm, 4.7 kg.
- AX300-30-11-85
The ABB AX300-30-11-85 is a 3-pole AC contactor with 3 normally open main contacts, 1 normally open auxiliary contact, and 1 normally closed auxiliary contact. It has a rated operational voltage of 1000 V for the main circuit and a rated frequency of 60 Hz. The conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V; 290 A at 55 °C for 500 V and 690 V. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V; 200 kW at 500 V; 250 kW at 690 V; and 90 kW at 220/230/240 V. Dimensions are 140 mm width, 180 mm depth, and 225 mm height, with a net weight of 4.7 kg.