- AX18-30-10-83
The ABB AX18-30-10-83 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, and a rated frequency of 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 380/400 V, 12 A at 440 V and 500 V, and 9 A at 690 V, all at 55 °C. Rated operational power AC-3 is 9 kW at 415 V, 7.5 kW at 500 V and 690 V, and 4 kW at 220/230/240 V. The contactor uses screw terminals, measures 44 mm wide by 74 mm deep by 74 mm high, and weighs 0.326 kg. Coil voltage is 48 V at 50 Hz and 60 Hz.
- AX18-30-10-84
The ABB AX18-30-10-84 is a three-pole block-type AC contactor with three normally open main contacts and one normally open auxiliary contact. It has screw terminals and measures 44 mm wide, 74 mm deep, and 74 mm high, weighing 0.326 kg. The coil is rated 110 V at 50 Hz and 110 to 120 V at 60 Hz. Main and auxiliary circuits are rated 690 V at 50/60 Hz, with insulation rated 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C). AC-3 ratings include 18 A at 415 V and 9 kW at 415 V, both at 55 °C. Terminal protection is IP20 according to IEC 60529. Maximum operating altitude without derating is 3000 m.
- AX18-30-10-85
The ABB AX18-30-10-85 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 28 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 18 A at 380/400 V and 415 V, both at 55 °C, with rated operational power of 7.5 kW at 380/400 V and 9 kW at 415 V. The control circuit is rated 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; weight is 0.326 kg. Terminals are screw type, IP20.
- AX18-30-10-86
ABB AX18-30-10-86 AC contactor, manufacturer ID 1SBL921074R8610. It has three main contacts NO, no main contacts NC, and one auxiliary contact NO. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 380/400 V, 12 A at 440 V and 500 V, and 9 A at 690 V, all at 55 °C. Rated operational power AC-3 is 9 kW at 415 V, 7.5 kW at 380/400 V, 500 V, and 690 V, 5.5 kW at 440 V, and 4 kW at 220/230/240 V. Coil voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Dimensions are 44 mm width, 74 mm depth, 74 mm height; weight 0.326 kg. Screw terminals, IP20.
- AX18-30-10-88
The ABB AX18-30-10-88 is an AC contactor with manufacturer ID 1SBL921074R8810. It has three main poles (NO) and one built-in auxiliary contact (NO), with screw terminals. The rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 55 °C, and rated operational power AC-3 is 9 kW at 415 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.326 kg. Terminal protection is IP20 according to IEC 60529, IEC 60947-1, and EN 60529.
- AX185-30-11-80
ABB AX185-30-11-80 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 111.5 mm wide, 162.3 mm deep, and 196 mm high, and weighs 3.2 kg. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, 145 A at 440 V and 55 °C, and 120 A at 690 V and 55 °C. Maximum electrical switching frequency is 300 cycles per hour. Rated impulse withstand voltage is 8 kV. Manufacturer ID 1SFL491074R8011.
- AX185-30-11-81
The ABB AX185-30-11-81 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, with rated operational power AC-3 of 90 kW at 415 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and rated impulse withstand voltage is 8 kV. Dimensions are 111.5 mm wide, 162.3 mm deep, and 196 mm high, with a net weight of 3.2 kg.
- AX185-30-11-83
ABB AX185-30-11-83 AC contactor, manufacturer ID 1SFL491074R8311. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, and 185 A at 380/400 V and 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 90 kW at 380/400 V. Dimensions are 111.5 mm wide, 162.3 mm deep, and 196 mm high; net weight is 3.2 kg.