- AX18-30-10-85
The ABB AX18-30-10-85 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 28 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 18 A at 380/400 V and 415 V, both at 55 °C, with rated operational power of 7.5 kW at 380/400 V and 9 kW at 415 V. The control circuit is rated 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; weight is 0.326 kg. Terminals are screw type, IP20.
- AX18-30-10-86
ABB AX18-30-10-86 AC contactor, manufacturer ID 1SBL921074R8610. It has three main contacts NO, no main contacts NC, and one auxiliary contact NO. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 380/400 V, 12 A at 440 V and 500 V, and 9 A at 690 V, all at 55 °C. Rated operational power AC-3 is 9 kW at 415 V, 7.5 kW at 380/400 V, 500 V, and 690 V, 5.5 kW at 440 V, and 4 kW at 220/230/240 V. Coil voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Dimensions are 44 mm width, 74 mm depth, 74 mm height; weight 0.326 kg. Screw terminals, IP20.
- AX18-30-10-88
The ABB AX18-30-10-88 is an AC contactor with manufacturer ID 1SBL921074R8810. It has three main poles (NO) and one built-in auxiliary contact (NO), with screw terminals. The rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 55 °C, and rated operational power AC-3 is 9 kW at 415 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.326 kg. Terminal protection is IP20 according to IEC 60529, IEC 60947-1, and EN 60529.
- AX185-30-11-80
ABB AX185-30-11-80 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 111.5 mm wide, 162.3 mm deep, and 196 mm high, and weighs 3.2 kg. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, 145 A at 440 V and 55 °C, and 120 A at 690 V and 55 °C. Maximum electrical switching frequency is 300 cycles per hour. Rated impulse withstand voltage is 8 kV. Manufacturer ID 1SFL491074R8011.
- AX185-30-11-81
The ABB AX185-30-11-81 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, with rated operational power AC-3 of 90 kW at 415 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and rated impulse withstand voltage is 8 kV. Dimensions are 111.5 mm wide, 162.3 mm deep, and 196 mm high, with a net weight of 3.2 kg.
- AX185-30-11-83
ABB AX185-30-11-83 AC contactor, manufacturer ID 1SFL491074R8311. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, and 185 A at 380/400 V and 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 90 kW at 380/400 V. Dimensions are 111.5 mm wide, 162.3 mm deep, and 196 mm high; net weight is 3.2 kg.
- AX185-30-11-85
The ABB AX185-30-11-85 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 111.5 mm wide, 162.3 mm deep, and 196 mm high, and weighs 3.2 kg. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, and rated operational power AC-3 is 90 kW at 415 V. Maximum electrical switching frequency is 300 cycles per hour. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 8 kV.
- AX185-30-11-86
The ABB AX185-30-11-86 is an AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. Main circuit rated operational voltage is 1000 V at 50 Hz. Conventional free-air thermal current is 250 A per IEC 60947-4-1 for open contactors at 40 °C. AC-1 rated operational current is 250 A at 690 V and 40 °C. AC-3 rated operational current at 380/400 V and 55 °C is 185 A, with rated operational power of 90 kW at 380/400 V. Maximum electrical switching frequency is 300 cycles per hour; maximum mechanical switching frequency is 3600 cycles per hour. Mechanical durability is 5 million operations. Dimensions are 111.5 mm wide, 162.3 mm deep, and 196 mm high; net weight is 3.2 kg.