- AX185-30-11-80
ABB AX185-30-11-80 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 111.5 mm wide, 162.3 mm deep, and 196 mm high, and weighs 3.2 kg. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, 145 A at 440 V and 55 °C, and 120 A at 690 V and 55 °C. Maximum electrical switching frequency is 300 cycles per hour. Rated impulse withstand voltage is 8 kV. Manufacturer ID 1SFL491074R8011.
- AX185-30-11-81
The ABB AX185-30-11-81 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, with rated operational power AC-3 of 90 kW at 415 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and rated impulse withstand voltage is 8 kV. Dimensions are 111.5 mm wide, 162.3 mm deep, and 196 mm high, with a net weight of 3.2 kg.
- AX185-30-11-83
ABB AX185-30-11-83 AC contactor, manufacturer ID 1SFL491074R8311. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, and 185 A at 380/400 V and 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 90 kW at 380/400 V. Dimensions are 111.5 mm wide, 162.3 mm deep, and 196 mm high; net weight is 3.2 kg.
- AX185-30-11-85
The ABB AX185-30-11-85 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 111.5 mm wide, 162.3 mm deep, and 196 mm high, and weighs 3.2 kg. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, and rated operational power AC-3 is 90 kW at 415 V. Maximum electrical switching frequency is 300 cycles per hour. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 8 kV.
- AX185-30-11-86
The ABB AX185-30-11-86 is an AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. Main circuit rated operational voltage is 1000 V at 50 Hz. Conventional free-air thermal current is 250 A per IEC 60947-4-1 for open contactors at 40 °C. AC-1 rated operational current is 250 A at 690 V and 40 °C. AC-3 rated operational current at 380/400 V and 55 °C is 185 A, with rated operational power of 90 kW at 380/400 V. Maximum electrical switching frequency is 300 cycles per hour; maximum mechanical switching frequency is 3600 cycles per hour. Mechanical durability is 5 million operations. Dimensions are 111.5 mm wide, 162.3 mm deep, and 196 mm high; net weight is 3.2 kg.
- AX185-30-11-88
The ABB AX185-30-11-88 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 111.5 mm wide, 162.3 mm deep, and 196 mm high, and weighs 3.2 kg. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 250 A at 40 °C according to IEC 60947-4-1 for open contactors. Rated operational current AC-3 is 185 A at 380/400 V and 415 V, both at 55 °C, and 120 A at 690 V at 55 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 8 kV. Maximum electrical switching frequency is 300 cycles per hour.
- AX205-30-11-36
The ABB AX205-30-11-36 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Rated operational current AC-1 is 275 A at 690 V and 40 °C, 250 A at 690 V and 55 °C, and 180 A at 690 V and 70 °C. Rated operational current AC-3 is 205 A at 415 V and 55 °C, 185 A at 440 V and 55 °C, and 170 A at 500 V and 690 V and 55 °C. Maximum operating altitude without derating is 3000 m. Dimensions are 111.5 mm wide, 162.3 mm deep, and 196 mm high; net weight is 3.2 kg. Manufacturer ID: 1SFL501074R3611.
- AX205-30-11-81
The ABB AX205-30-11-81 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V and 50 Hz, with a rated control circuit voltage of 24 V at both 50 Hz and 60 Hz. Rated operational current AC-3 is 205 A at 380/400 V, 220/230/240 V, and 415 V at 55 °C, and 170 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 is 110 kW at 380/400 V and 415 V, 90 kW at 440 V, 110 kW at 500 V, 132 kW at 690 V, and 59 kW at 220/230/240 V. Dimensions are 111.5 mm wide, 162.3 mm deep, and 196 mm high, weighing 3.2 kg.