Industrial Automation Parts. Prompt replies from real people.

ABB AX185-30-11-88 Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the ABB AX185-30-11-88?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AX185-30-11-88 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AX185-30-11-88
Material Number
1SFL491074R8811
Manufacturer
ABB
Product ID
91844

Get a Free Quote

Request pricing and availability for AX185-30-11-88.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
3.2 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 250 A (690 V) 55 °C 230 A (690 V) 70 °C 180 A
Rated Operational Power AC-3 (Pe)
(415 V) 90 kW (440 V) 75 kW (500 V) 90 kW (690 V) 110 kW (380 / 400 V) 90 kW (220 / 230 / 240 V) 55 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
See all specifications

Product Highlights

  1. Main Contacts: 3 normally open (NO) main contacts and no normally closed (NC) main contacts
  2. Auxiliary Contacts: 1 normally open (NO) and 1 normally closed (NC) auxiliary contact
  3. Current Ratings: Conventional free-air thermal current (Ith) 250 A at 40 °C per IEC 60947-4-1, with AC-1 ratings of 250 A at 40 °C, 230 A at 55 °C, and 180 A at 70 °C at 690 V
  4. AC-3 Ratings: Rated operational current AC-3 of 185 A at 380/400 V and 415 V, 145 A at 440 V and 500 V, and 120 A at 690 V, all at 55 °C, with rated operational power AC-3 up to 110 kW at 690 V
  5. Voltage and Switching: Rated operational voltage 1000 V, rated insulation voltage 690 V per IEC 60947-4-1 and VDE 0110, rated impulse withstand voltage 8 kV, maximum mechanical switching frequency 3600 cycles per hour, maximum electrical switching frequency 300 cycles per hour, and mechanical durability 5 million operations
  6. Coil and Ambient Range: Rated control circuit voltage 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz, with ambient air temperature range of -40 to 70 °C without thermal overload relay and -25 to 55 °C with thermal overload relay
  7. Terminations and Protection: Main circuit bar terminals, auxiliary terminals IP40 per IEC 60529, and maximum operating altitude 3000 m without derating
AX185-30-11-88

Product Information

Technical Specifications

Specifications for AX185-30-11-88

ParameterValue
Product Net Width111.5 mm
Product Net Depth / Length162.3 mm
Product Net Height196 mm
Product Net Weight3.2 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 250 A (690 V) 55 °C 230 A (690 V) 70 °C 180 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 185 A (440 V) 55 °C 145 A (500 V) 55 °C 145 A (690 V) 55 °C 120 A (380400 V) 55 °C 185 A (220230240 V) 55 °C 185 A
Rated Operational Power AC-3 (Pe)(415 V) 90 kW (440 V) 75 kW (500 V) 90 kW (690 V) 110 kW (380400 V) 90 kW (220230240 V) 55 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
ParameterValue
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
Maximum Electrical Switching Frequency300 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Mechanical Durability5 million
Maximum Mechanical Switching Frequency3600 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 230 ... 240 V 60 Hz 240 ... 260 V
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal TypeMain Circuit: Bars
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
Manufacturer ID1SFL491074R8811

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
AX185-30-11-88 Contactor by ABB - High-Performance 3-Pole AC Operated