- AX205-30-11-84
The ABB AX205-30-11-84 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 111.5 mm wide, 162.3 mm deep, and 196 mm high, and weighs 3.2 kg. The main circuit is rated for 1000 V operational voltage and 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 205 A at 415 V and 55 °C, and rated operational power AC-3 is 110 kW at 415 V. Maximum electrical switching frequency is 300 cycles per hour. Rated impulse withstand voltage is 8 kV.
- AX205-30-11-85
The ABB AX205-30-11-85 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Rated operational voltage of the main circuit is 1000 V at 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 205 A at 415 V and 55 °C, and rated operational power AC-3 is 110 kW at 415 V. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), with rated impulse withstand voltage of 8 kV. Coil voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Dimensions are 111.5 mm wide, 162.3 mm deep, and 196 mm high; net weight is 3.2 kg.
- AX205-30-11-86
ABB AX205-30-11-86 AC contactor, manufacturer ID 1SFL501074R8611. It has three main poles (3 NO, 0 NC) and one auxiliary contact each NO and NC. Main circuit rated operational voltage is 1000 V at 60 Hz. Conventional free-air thermal current is 250 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 205 A at 415 V and 55 °C, and rated operational power AC-3 is 110 kW at 415 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 8 kV. Dimensions are 111.5 mm wide, 162.3 mm deep, 196 mm high; net weight 3.2 kg.
- AX205-30-11-88
The ABB AX205-30-11-88 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50 Hz, with a rated insulation voltage of 690 V to IEC 60947-4-1 and VDE 0110 (Gr. C), and a rated impulse withstand voltage of 8 kV. Conventional free-air thermal current is 250 A to IEC 60947-4-1 for open contactors at 40 °C. AC-3 operational current is 205 A at 415 V and 55 °C, with AC-3 operational power of 110 kW at 415 V. Dimensions are 111.5 mm wide, 162.3 mm deep, and 196 mm high, weighing 3.2 kg.
- AX25-30-01-26
The ABB AX25-30-01-26 is a block-type AC contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 32 A at 40 °C; AC-1 ratings include 32 A at 690 V and 40 °C. AC-3 ratings include 25 A at 380/400 V and 55 °C, corresponding to 11 kW, and 10 A at 690 V and 55 °C. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.326 kg. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C).
- AX25-30-01-36
The ABB AX25-30-01-36 is an AC contactor with three main normally open contacts and one normally closed auxiliary contact. It measures 44 mm wide, 74 mm deep, and 76.3 mm high, and weighs 0.326 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 25 A at 380/400 V, 415 V, 220/230/240 V, and 16 A at 440 V, all at 55 °C. Rated operational power AC-3 is 11 kW at 380/400 V and 415 V. Coil control voltage is 190 V at 50 Hz and 220 V at 60 Hz. Terminals are screw type, with IP20 protection on main, auxiliary, and coil terminals.
- AX25-30-01-75
The ABB AX25-30-01-75 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 690 V and a frequency of 50/60 Hz. The conventional free-air thermal current is 32 A at 40°C according to IEC 60947-4-1 for open contactors. Rated operational current for AC-3 is 25 A at 380/400 V and 415 V, both at 55°C, and 10 A at 690 V at 55°C. Corresponding AC-3 power ratings include 11 kW at 380/400 V and 415 V, and 9 kW at 440 V, 500 V, and 690 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.326 kg.
- AX25-30-01-80
The ABB AX25-30-01-80 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 44 mm wide, 74 mm deep, and 76.3 mm high, and weighs 0.326 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 32 A at 40 °C. AC-3 rated operational current is 25 A at 380/400 V and 415 V, both at 55 °C, corresponding to 11 kW. The coil is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Terminals are screw type with IP20 protection.