- AX25-30-01-80
The ABB AX25-30-01-80 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 44 mm wide, 74 mm deep, and 76.3 mm high, and weighs 0.326 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 32 A at 40 °C. AC-3 rated operational current is 25 A at 380/400 V and 415 V, both at 55 °C, corresponding to 11 kW. The coil is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Terminals are screw type with IP20 protection.
- AX25-30-01-81
The ABB AX25-30-01-81 is a block-type AC contactor with three main poles (3 NO) and one built-in auxiliary contact (1 NC). It is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 32 A at 40 °C per IEC 60947-4-1. AC-3 rated operational power is 11 kW at 380/400 V and 415 V, 9 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. The coil operates at 24 V AC, 50 Hz or 60 Hz. Dimensions are 44 mm wide, 74 mm deep, and 76.3 mm high; net weight is 0.326 kg. Terminals are screw type, IP20.
- AX25-30-01-83
The ABB AX25-30-01-83 is an AC contactor with three normally open main contacts, no normally open auxiliary contacts, and one normally closed auxiliary contact. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz, with a rated control circuit voltage of 48 V at 50 Hz and 60 Hz. Rated operational current AC-3 is 25 A at 380/400 V and 415 V, 16 A at 440 V, 14 A at 500 V, and 10 A at 690 V. Rated operational power AC-3 is 11 kW at 380/400 V and 415 V, 9 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Dimensions are 44 mm wide, 74 mm deep, and 76.3 mm high; weight is 0.326 kg. Terminals are screw type, IP20.
- AX25-30-01-84
The ABB AX25-30-01-84 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 25 A at 380/400 V and 415 V, and 10 A at 690 V, all at 55 °C. Rated operational power AC-3 is 11 kW at 380/400 V and 415 V, and 9 kW at 440 V, 500 V, and 690 V. The coil is rated 110 V at 50 Hz and 110 to 120 V at 60 Hz. Terminals are screw type, with IP20 protection on main, auxiliary, and coil terminals. Dimensions are 44 mm wide, 74 mm deep, and 76.3 mm high; net weight is 0.326 kg.
- AX25-30-01-85
The ABB AX25-30-01-85 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, and operates at 50/60 Hz. Conventional free-air thermal current is 32 A at 40 °C according to IEC 60947-4-1, and 16 A at 40 °C according to IEC 60947-5-1. Rated operational current AC-3 is 25 A at 380/400 V and 415 V, both at 55 °C, with corresponding rated power of 11 kW. The control circuit voltage is 380–400 V at 50 Hz and 400–415 V at 60 Hz. Maximum mechanical switching frequency is 3600 cycles per hour. Dimensions are 44 mm wide, 74 mm deep, and 76.3 mm high; net weight is 0.326 kg. Terminals are screw type.
- AX25-30-01-86
The ABB AX25-30-01-86 is an AC-operated block-type contactor with three main poles (3 NO, 0 NC) and one built-in auxiliary contact (0 NO, 1 NC). It has screw terminals and measures 44 mm wide, 74 mm deep, and 76.3 mm high, weighing 0.326 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 25 A at 380/400 V and 415 V, 16 A at 440 V, 14 A at 500 V, and 10 A at 690 V, all at 55 °C. Rated control circuit voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Degree of protection is IP20 for main, auxiliary, and coil terminals.
- AX25-30-01-88
The ABB AX25-30-01-88 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 44 mm wide, 74 mm deep, and 76.3 mm high, and weighs 0.326 kg. The coil is rated 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 25 A at 415 V and 380/400 V, both at 55 degrees C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V. Terminals are screw type, IP20. Maximum operating altitude without derating is 3000 m.
- AX25-30-10-26
The ABB AX25-30-10-26 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 32 A per IEC 60947-4-1 and 16 A per IEC 60947-5-1, at 40 °C. AC-3 rated operational current is 25 A at 415 V and 380/400 V, and rated operational power is 11 kW at 415 V and 380/400 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C).