- AX09-30-10-88
The ABB AX09-30-10-88 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Rated operational current AC-3 is 9 A at 380/400 V, 415 V, 440 V, 500 V, and 220/230/240 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 4 kW at 380/400 V, 415 V, and 440 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, weighing 0.326 kg. Terminals are screw type, IP20.
- AX115-30-11-36
The ABB AX115-30-11-36 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Its rated operational current in AC-1 is 160 A at 690 V and 40 °C, 145 A at 55 °C, and 130 A at 70 °C. In AC-3 it is rated 115 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, 100 A at 500 V and 55 °C, 82 A at 690 V and 55 °C, 115 A at 380/400 V and 55 °C, and 115 A at 220/230/240 V and 55 °C. Maximum operating altitude without derating is 3000 m. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.9 kg. Manufacturer ID: 1SFL981074R3611.
- AX115-30-11-75
The ABB AX115-30-11-75 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 690 V and 55 °C, and 130 A at 690 V and 70 °C. Rated operational current AC-3 is 115 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, 100 A at 500 V and 55 °C, 82 A at 690 V and 55 °C, 115 A at 380/400 V and 55 °C, and 115 A at 220/230/240 V and 55 °C. Maximum operating altitude without derating is 3000 m. Manufacturer ID: 1SFL981074R7511.
- AX115-30-11-80
The ABB AX115-30-11-80 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V and a frequency of 50 Hz. The conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current at 415 V and 55 °C is 115 A, with a corresponding rated operational power of 59 kW. The contactor has a rated insulation voltage of 690 V per IEC 60947-4-1 and VDE 0110, an impulse withstand voltage of 8 kV, and mechanical durability of 10 million operations. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, weighing 1.9 kg.
- AX115-30-11-81
ABB AX115-30-11-81 AC contactor with manufacturer ID 1SFL981074R8111. Three-pole main circuit with 3 NO main contacts, 1 NO and 1 NC auxiliary contacts. Rated operational voltage 1000 V; rated frequency 60 Hz. Rated control circuit voltage 24 V at 50 Hz and 24 V at 60 Hz. Conventional free-air thermal current 160 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current 115 A at 380/400 V and 55 °C. Maximum electrical switching frequency 300 cycles per hour; maximum mechanical switching frequency 3600 cycles per hour. Mechanical durability 10 million operations. Dimensions 102 mm wide, 123.5 mm deep, 148 mm high; net weight 1.9 kg.
- AX115-30-11-83
The ABB AX115-30-11-83 is a 3-pole AC-operated contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 115 A at 415 V and 55 °C, and rated operational power AC-3 is 59 kW at 415 V. Rated breaking capacity is 8 x Ie AC-3 and making capacity is 10 x Ie AC-3. Maximum mechanical switching frequency is 3600 cycles per hour; maximum electrical switching frequency is 300 cycles per hour. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.9 kg.
- AX115-30-11-84
The ABB AX115-30-11-84 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 115 A at 415 V and 55 °C, and rated operational power AC-3 is 59 kW at 415 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations, with maximum mechanical switching frequency 3600 cycles per hour. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight 1.9 kg.
- AX115-30-11-85
The ABB AX115-30-11-85 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 115 A at 415 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V and 75 kW at 690 V. Rated breaking capacity AC-3 is 8 x Ie, making capacity is 10 x Ie, and maximum electrical switching frequency is 300 cycles per hour.