- AX115-30-11-81
ABB AX115-30-11-81 AC contactor with manufacturer ID 1SFL981074R8111. Three-pole main circuit with 3 NO main contacts, 1 NO and 1 NC auxiliary contacts. Rated operational voltage 1000 V; rated frequency 60 Hz. Rated control circuit voltage 24 V at 50 Hz and 24 V at 60 Hz. Conventional free-air thermal current 160 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current 115 A at 380/400 V and 55 °C. Maximum electrical switching frequency 300 cycles per hour; maximum mechanical switching frequency 3600 cycles per hour. Mechanical durability 10 million operations. Dimensions 102 mm wide, 123.5 mm deep, 148 mm high; net weight 1.9 kg.
- AX115-30-11-83
The ABB AX115-30-11-83 is a 3-pole AC-operated contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 115 A at 415 V and 55 °C, and rated operational power AC-3 is 59 kW at 415 V. Rated breaking capacity is 8 x Ie AC-3 and making capacity is 10 x Ie AC-3. Maximum mechanical switching frequency is 3600 cycles per hour; maximum electrical switching frequency is 300 cycles per hour. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.9 kg.
- AX115-30-11-84
The ABB AX115-30-11-84 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 115 A at 415 V and 55 °C, and rated operational power AC-3 is 59 kW at 415 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations, with maximum mechanical switching frequency 3600 cycles per hour. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight 1.9 kg.
- AX115-30-11-85
The ABB AX115-30-11-85 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 115 A at 415 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V and 75 kW at 690 V. Rated breaking capacity AC-3 is 8 x Ie, making capacity is 10 x Ie, and maximum electrical switching frequency is 300 cycles per hour.
- AX115-30-11-86
ABB AX115-30-11-86 AC contactor, manufacturer ID 1SFL981074R8611. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 115 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V and 75 kW at 690 V. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight 1.9 kg.
- AX115-30-11-88
The ABB AX115-30-11-88 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 115 A at 415 V and 55 °C, and rated operational power AC-3 is 59 kW at 415 V. Maximum electrical switching frequency is 300 cycles per hour. Rated impulse withstand voltage is 8 kV.
- AX12-30-01-26
ABB AX12-30-01-26 AC contactor, manufacturer ID 1SBL911074R2601. Block-type device with 3 main poles (NO) and 1 auxiliary contact (NC). Rated operational voltage: main and auxiliary circuits 690 V; rated frequency 50/60 Hz. Conventional free-air thermal current per IEC 60947-4-1 at 40 °C is 26 A; per IEC 60947-5-1 at 40 °C is 16 A. Rated operational current AC-3: 12 A at 415 V and 380/400 V, 9 A at 440 V and 500 V, 7 A at 690 V, all at 55 °C. Rated operational power AC-3: 5.5 kW at 415 V, 500 V, and 690 V; 4 kW at 440 V; 3 kW at 220/230/240 V. Rated insulation voltage per IEC 60947-4-1 and VDE 0110 (Gr. C): 690 V. Dimensions 44 x 74 x 74 mm; weight 0.326 kg.
- AX12-30-01-36
ABB AX12-30-01-36 AC contactor, manufacturer ID 1SBL911074R3601. It has three main contacts NO, no main contacts NC, and one auxiliary contact NC. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current Ith is 26 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 12 A at 415 V and 55 °C, with rated operational power AC-3 of 5.5 kW at 415 V. Coil control voltage is 190 V at 50 Hz and 220 V at 60 Hz. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.326 kg. Terminals are screw type, IP20.