- AX115-30-11-85
The ABB AX115-30-11-85 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 115 A at 415 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V and 75 kW at 690 V. Rated breaking capacity AC-3 is 8 x Ie, making capacity is 10 x Ie, and maximum electrical switching frequency is 300 cycles per hour.
- AX115-30-11-86
ABB AX115-30-11-86 AC contactor, manufacturer ID 1SFL981074R8611. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 115 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, and 82 A at 690 V and 55 °C. Rated operational power AC-3 is 59 kW at 415 V and 75 kW at 690 V. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight 1.9 kg.
- AX115-30-11-88
The ABB AX115-30-11-88 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 115 A at 415 V and 55 °C, and rated operational power AC-3 is 59 kW at 415 V. Maximum electrical switching frequency is 300 cycles per hour. Rated impulse withstand voltage is 8 kV.
- AX12-30-01-26
ABB AX12-30-01-26 AC contactor, manufacturer ID 1SBL911074R2601. Block-type device with 3 main poles (NO) and 1 auxiliary contact (NC). Rated operational voltage: main and auxiliary circuits 690 V; rated frequency 50/60 Hz. Conventional free-air thermal current per IEC 60947-4-1 at 40 °C is 26 A; per IEC 60947-5-1 at 40 °C is 16 A. Rated operational current AC-3: 12 A at 415 V and 380/400 V, 9 A at 440 V and 500 V, 7 A at 690 V, all at 55 °C. Rated operational power AC-3: 5.5 kW at 415 V, 500 V, and 690 V; 4 kW at 440 V; 3 kW at 220/230/240 V. Rated insulation voltage per IEC 60947-4-1 and VDE 0110 (Gr. C): 690 V. Dimensions 44 x 74 x 74 mm; weight 0.326 kg.
- AX12-30-01-36
ABB AX12-30-01-36 AC contactor, manufacturer ID 1SBL911074R3601. It has three main contacts NO, no main contacts NC, and one auxiliary contact NC. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current Ith is 26 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 12 A at 415 V and 55 °C, with rated operational power AC-3 of 5.5 kW at 415 V. Coil control voltage is 190 V at 50 Hz and 220 V at 60 Hz. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.326 kg. Terminals are screw type, IP20.
- AX12-30-01-75
The ABB AX12-30-01-75 is a block-type AC contactor with three main poles (3 NO) and one built-in auxiliary contact (1 NC). It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 26 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 12 A at 415 V and 55 °C, with rated operational power AC-3 of 5.5 kW at 415 V. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C).
- AX12-30-01-80
The ABB AX12-30-01-80 is an AC contactor with three main poles (3 NO, 0 NC) and one built-in auxiliary contact (0 NO, 1 NC). The rated control circuit voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, and 7 A at 690 V, each at 55 °C. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.326 kg. Terminals are screw type, rated IP20, and the maximum operating altitude without derating is 3000 m.
- AX12-30-01-81
ABB AC contactor AX12-30-01-81, manufacturer ID 1SBL911074R8101. Three main poles normally open and one auxiliary contact normally closed. Coil voltage 24 V at 50 Hz and 24 V at 60 Hz. Rated operational voltage 690 V for main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, 9 A at 440 V and 500 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, 500 V, and 690 V. Screw terminals, IP20 on main, auxiliary, and coil terminals. Dimensions 44 mm wide, 74 mm deep, 74 mm high; net weight 0.326 kg. Maximum mechanical switching frequency 3600 cycles per hour.