- AX12-30-01-36
ABB AX12-30-01-36 AC contactor, manufacturer ID 1SBL911074R3601. It has three main contacts NO, no main contacts NC, and one auxiliary contact NC. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current Ith is 26 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 12 A at 415 V and 55 °C, with rated operational power AC-3 of 5.5 kW at 415 V. Coil control voltage is 190 V at 50 Hz and 220 V at 60 Hz. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.326 kg. Terminals are screw type, IP20.
- AX12-30-01-75
The ABB AX12-30-01-75 is a block-type AC contactor with three main poles (3 NO) and one built-in auxiliary contact (1 NC). It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 26 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 12 A at 415 V and 55 °C, with rated operational power AC-3 of 5.5 kW at 415 V. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C).
- AX12-30-01-80
The ABB AX12-30-01-80 is an AC contactor with three main poles (3 NO, 0 NC) and one built-in auxiliary contact (0 NO, 1 NC). The rated control circuit voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, and 7 A at 690 V, each at 55 °C. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.326 kg. Terminals are screw type, rated IP20, and the maximum operating altitude without derating is 3000 m.
- AX12-30-01-81
ABB AC contactor AX12-30-01-81, manufacturer ID 1SBL911074R8101. Three main poles normally open and one auxiliary contact normally closed. Coil voltage 24 V at 50 Hz and 24 V at 60 Hz. Rated operational voltage 690 V for main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, 9 A at 440 V and 500 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, 500 V, and 690 V. Screw terminals, IP20 on main, auxiliary, and coil terminals. Dimensions 44 mm wide, 74 mm deep, 74 mm high; net weight 0.326 kg. Maximum mechanical switching frequency 3600 cycles per hour.
- AX12-30-01-83
The ABB AX12-30-01-83 is a block-type AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has screw terminals and measures 44 mm wide, 74 mm deep, and 74 mm high, weighing 0.326 kg. The rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. The rated control circuit voltage is 48 V at 50 Hz and 48 V at 60 Hz. Conventional free-air thermal current is 26 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 12 A at 415 V and 55 °C. Rated operational power AC-3 is 5.5 kW at 415 V. Maximum operating altitude without derating is 3000 m.
- AX12-30-01-84
The ABB AX12-30-01-84 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated control circuit voltage is 110 V at 50 Hz and 110 to 120 V at 60 Hz. Rated operational current AC-3 is 12 A at 415 V and 380/400 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 5.5 kW at 415 V and 380/400 V. Dimensions are 44 mm width, 74 mm depth, 74 mm height; net weight 0.326 kg. Screw terminals, IP20. Rated insulation voltage 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C).
- AX12-30-01-85
The ABB AX12-30-01-85 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, and a rated frequency of 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, 9 A at 440 V and 500 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, 500 V, and 690 V, and 3 kW at 220/230/240 V. The contactor uses screw terminals, has IP20 protection on main, auxiliary, and coil terminals, and measures 44 mm wide, 74 mm deep, and 74 mm high, weighing 0.326 kg.
- AX12-30-01-86
The ABB AX12-30-01-86 is a block-type AC contactor with three main poles (3 NO, 0 NC) and one built-in auxiliary contact (0 NO, 1 NC). It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, 500 V, and 690 V. Coil voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Terminals are screw type, IP20.