- AX12-30-01-86
The ABB AX12-30-01-86 is a block-type AC contactor with three main poles (3 NO, 0 NC) and one built-in auxiliary contact (0 NO, 1 NC). It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, 500 V, and 690 V. Coil voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Terminals are screw type, IP20.
- AX12-30-01-88
ABB AX12-30-01-88 AC contactor, manufacturer ID 1SBL911074R8801. It has three normally open main contacts and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. AC-3 rated operational current is 12 A at 415 V and 380/400 V, 9 A at 440 V and 500 V, and 7 A at 690 V, all at 55 °C. AC-3 rated power is 5.5 kW at 415 V, 500 V, 690 V, and 380/400 V, and 4 kW at 440 V. Dimensions are 44 mm wide, 74 mm deep, 74 mm high; net weight 0.326 kg. Screw terminals. IP20. Maximum operating altitude without derating is 3000 m.
- AX12-30-10-26
The ABB AX12-30-10-26 is a block-type AC contactor with three normally open main contacts and one normally open auxiliary contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, and operates at 50 or 60 Hz. The conventional free-air thermal current is 26 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 12 A at 415 V and 55 °C, with a corresponding rated operational power of 5.5 kW at 415 V. The contactor measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. The manufacturer ID is 1SBL911074R2610.
- AX12-30-10-36
ABB AX12-30-10-36 AC contactor, manufacturer ID 1SBL911074R3610. It has three normally open main contacts, one normally open auxiliary contact, and no normally closed contacts. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V, 415 V, and 220/230/240 V, 9 A at 440 V and 500 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, 500 V, and 690 V, 4 kW at 440 V, and 3 kW at 220/230/240 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.326 kg. Screw terminals, IP20. Coil voltage 190 V at 50 Hz, 220 V at 60 Hz.
- AX12-30-10-75
The ABB AX12-30-10-75 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 26 A at 40 °C according to IEC 60947-4-1, and 16 A at 40 °C according to IEC 60947-5-1. Rated operational current AC-3 is 12 A at 415 V and 55 °C, with rated operational power AC-3 of 5.5 kW at 415 V. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C). Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, weighing 0.326 kg.
- AX12-30-10-80
The ABB AX12-30-10-80 is an AC contactor with three main poles (3 NO, 0 NC) and one built-in auxiliary contact (1 NO, 0 NC). It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. The coil is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Main and auxiliary circuits are rated 690 V with a rated insulation voltage of 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C). Rated operational current AC-3 is 12 A at 380/400 V and 415 V, both at 55 °C. Screw terminals; IP20 on main, coil, and auxiliary terminals. Maximum operating altitude without derating is 3000 m.
- AX12-30-10-81
The ABB AX12-30-10-81 is a block-type AC contactor with three main poles (NO) and one built-in auxiliary contact (NO). It is rated 690 V for both main and auxiliary circuits at 50/60 Hz, with a rated control circuit voltage of 24 V at 50 Hz and 60 Hz. Rated operational current AC-3 is 12 A at 415 V and 380/400 V, 9 A at 440 V and 500 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 5.5 kW at 415 V, 500 V, 690 V, and 380/400 V, 4 kW at 440 V, and 3 kW at 220/230/240 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight is 0.326 kg. Terminals are screw type with IP20 protection.
- AX12-30-10-83
The ABB AX12-30-10-83 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, both at 55 °C, with rated operational power AC-3 of 5.5 kW at 380/400 V and 415 V. The coil voltage is 48 V at 50 Hz and 60 Hz. Terminals are screw type with IP20 protection on main, auxiliary, and coil terminals. Maximum operating altitude without derating is 3000 m.