- AX12-30-10-80
The ABB AX12-30-10-80 is an AC contactor with three main poles (3 NO, 0 NC) and one built-in auxiliary contact (1 NO, 0 NC). It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. The coil is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Main and auxiliary circuits are rated 690 V with a rated insulation voltage of 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C). Rated operational current AC-3 is 12 A at 380/400 V and 415 V, both at 55 °C. Screw terminals; IP20 on main, coil, and auxiliary terminals. Maximum operating altitude without derating is 3000 m.
- AX12-30-10-81
The ABB AX12-30-10-81 is a block-type AC contactor with three main poles (NO) and one built-in auxiliary contact (NO). It is rated 690 V for both main and auxiliary circuits at 50/60 Hz, with a rated control circuit voltage of 24 V at 50 Hz and 60 Hz. Rated operational current AC-3 is 12 A at 415 V and 380/400 V, 9 A at 440 V and 500 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 5.5 kW at 415 V, 500 V, 690 V, and 380/400 V, 4 kW at 440 V, and 3 kW at 220/230/240 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight is 0.326 kg. Terminals are screw type with IP20 protection.
- AX12-30-10-83
The ABB AX12-30-10-83 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, both at 55 °C, with rated operational power AC-3 of 5.5 kW at 380/400 V and 415 V. The coil voltage is 48 V at 50 Hz and 60 Hz. Terminals are screw type with IP20 protection on main, auxiliary, and coil terminals. Maximum operating altitude without derating is 3000 m.
- AX12-30-10-84
The ABB AX12-30-10-84 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. The coil is rated 110 V at 50 Hz and 110 to 120 V at 60 Hz. Main and auxiliary circuits are rated 690 V at 50/60 Hz, with conventional free-air thermal current of 26 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 12 A at 415 V and 380/400 V, 55 °C, and rated operational power is 5.5 kW at 415 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight is 0.326 kg. Terminals are screw type, degree of protection IP20. Maximum operating altitude without derating is 3000 m.
- AX12-30-10-85
ABB AX12-30-10-85 AC contactor, manufacturer ID 1SBL911074R8510. Block-type contactor with 3 main contacts NO, 0 main contacts NC, and 1 auxiliary contact NO. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, both at 55 °C, and 7 A at 690 V at 55 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, 500 V, and 690 V. Screw terminals; dimensions 44 mm width, 74 mm depth, 74 mm height; net weight 0.326 kg. Rated insulation voltage 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C). Terminal degree of protection IP20 per IEC 60529. Maximum operating altitude 3000 m without derating.
- AX12-30-10-86
The ABB AX12-30-10-86 is a block-type AC contactor with three main poles (3 NO, 0 NC) and one built-in auxiliary contact (1 NO, 0 NC). It uses screw terminals, and the main, auxiliary, and coil terminals are rated IP20 per IEC 60529, IEC 60947-1, and EN 60529. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. The coil is rated 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Rated operational current AC-3 is 12 A at 415 V and 380/400 V, and 9 A at 440 V and 500 V, at 55 °C. Rated operational power AC-3 is 5.5 kW at 415 V, 500 V, 690 V, and 380/400 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.326 kg.
- AX12-30-10-88
The ABB AX12-30-10-88 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. Its coil is rated for 50 Hz at 230 to 240 V and 60 Hz at 240 to 260 V. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, and rated operational power AC-3 is 5.5 kW at 380/400 V and 415 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight is 0.326 kg. Terminals are screw type, and protection is IP20 for main, auxiliary, and coil terminals.
- AX150-30-11-26
ABB AX150-30-11-26 AC contactor, manufacturer ID 1SFL991074R2611. It has three normally open main contacts, no normally closed main contacts, and one normally open plus one normally closed auxiliary contact. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 690 V and 55 °C, and 130 A at 690 V and 70 °C. Rated operational current AC-3 is 115 A at 415 V and 55 °C, 100 A at 440 V and 55 °C, 100 A at 500 V and 55 °C, 82 A at 690 V and 55 °C, 115 A at 380/400 V and 55 °C, and 115 A at 220/230/240 V and 55 °C. Maximum operating altitude without derating is 3000 m. Dimensions are 102 mm wide, 123.5 mm deep, 148 mm high; net weight 1.9 kg.