AX65-30-00-36
Material Number
1SBL371074R3600
Manufacturer
ABB
Product ID
74196

Get a Free Quote

Request pricing and availability for AX65-30-00-36.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.01 kg
Rated Operational Voltage
Auxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 95 A (690 V) 40 °C 115 A (690 V) 70 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 37 kW (440 V) 37 kW (500 V) 37 kW (690 V) 37 kW (380 / 400 V) 30 kW (220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
See all specifications

Product Highlights

  1. Main Contacts: 3 NO and 0 NC
  2. Auxiliary Contacts: 0 NO and 0 NC
  3. Coil Voltage: 190 V at 50 Hz and 220 V at 60 Hz
  4. Rated Operational Voltage: 690 V for main and auxiliary circuits
  5. Rated Frequency: 50 / 60 Hz for main and auxiliary circuits
  6. Conventional Free-air Thermal Current: 125 A according to IEC 60947-4-1 for open contactors at 40 °C
  7. Rated Operational Current AC-1: 95 A at 220 / 240 V and 55 °C, 115 A at 690 V and 40 °C, and 80 A at 690 V and 70 °C
  8. Rated Operational Current AC-3: 65 A at 220 / 230 / 240 V, 380 / 400 V, 415 V, and 440 V at 55 °C, 55 A at 500 V and 55 °C, and 43 A at 690 V and 55 °C
  9. Rated Operational Power AC-3: 18.5 kW at 220 / 230 / 240 V, 30 kW at 380 / 400 V, and 37 kW at 415 V, 440 V, 500 V, and 690 V
  10. Rated Short-time Withstand Current: 1000 A for 1 s, 650 A for 10 s, 370 A for 30 s, 250 A for 1 min, and 135 A for 15 min at 40 °C in free air from a cold state
  11. Maximum Breaking Capacity: 1300 A at 440 V and 630 A at 690 V
  12. Maximum Electrical Switching Frequency: 600 cycles per hour for AC-1 and AC-3
  13. Maximum Mechanical Switching Frequency: 3600 cycles per hour
  14. Rated Insulation Voltage: 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C)
  15. Rated Impulse Withstand Voltage: 6 kV for auxiliary circuit
  16. Operate Time: 7 to 14 ms between coil de-energization and NC contact closing, 4 to 11 ms between coil de-energization and NO contact opening, 7 to 22 ms between coil energization and NC contact opening, and 8 to 27 ms between coil energization and NO contact closing
  17. Degree of Protection: Coil terminals IP20 and main terminals IP10 according to IEC 60529, IEC 60947-1, and EN 60529
  18. Terminal Type: Screw terminals
  19. General Use Rating UL/CSA: 90 A at 600 V AC
  20. Horsepower Rating UL/CSA: 5 hp at 120 V AC single phase, 20 hp at 200 to 208 V AC three phase, 25 hp at 220 to 240 V AC three phase, 10 hp at 240 V AC single phase, 60 hp at 440 to 480 V AC three phase, and 75 hp at 550 to 600 V AC three phase
  21. Tightening Torque UL/CSA: 9 in·lb for auxiliary and control circuits and 35 in·lb for main circuit
  22. Ambient Air Temperature: -25 to 55 °C close to contactor fitted with thermal O/L relay, -40 to 70 °C close to contactor without thermal O/L relay, -60 to +80 °C close to contactor for storage, and -40 to 70 °C near contactor for operation in free air
  23. Climatic Withstand: according to IEC 60068-2-30 and 60068-2-11 and UTE C 63-100 specification II
  24. Maximum Operating Altitude: 3000 m without derating
  25. Dimensions: 70 mm width, 110 mm depth / length, and 108 mm height
  26. Net Weight: 1.01 kg
AX65-30-00-36

Product Information

Technical Specifications

Specifications for AX65-30-00-36

ParameterValue
Product Net Width70 mm
Product Net Depth / Length110 mm
Product Net Height108 mm
Product Net Weight1.01 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Rated Operational VoltageAuxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 5060 Hz Main Circuit 5060 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)(220 / 240 V) 55 °C 95 A (690 V) 40 °C 115 A (690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 65 A (440 V) 55 °C 65 A (500 V) 55 °C 55 A (690 V) 55 °C 43 A (380400 V) 55 °C 65 A (220230240 V) 55 °C 65 A
Rated Operational Power AC-3 (Pe)(415 V) 37 kW (440 V) 37 kW (500 V) 37 kW (690 V) 37 kW (380400 V) 30 kW (220230240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour (AC-3) 600 cycles per hour
ParameterValue
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 190 V 60 Hz 220 V
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 14 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil Energization and NC Contact Opening 7 ... 22 ms Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal TypeScrew Terminals
General Use Rating UL/CSA(600 V AC) 90 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 5 hp (200 ... 208 V AC) Three Phase 20 hp (220 ... 240 V AC) Three Phase 25 hp (240 V AC) Single Phase 10 hp (440 ... 480 V AC) Three Phase 60 hp (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb Control Circuit 9 in·lb Main Circuit 35 in·lb
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C Close to Contactor without Thermal O/L Relay -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstandacc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
Manufacturer ID1SBL371074R3600