- AX65-30-00-84
ABB AX65-30-00-84 AC contactor, manufacturer ID 1SBL371074R8400. Three main contacts NO, no auxiliary contacts. Rated operational voltage 690 V for main and auxiliary circuits at 50/60 Hz. Rated control circuit voltage 110 V at 50 Hz and 110 to 120 V at 60 Hz. Conventional free-air thermal current 125 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3: 65 A at 415 V and 55 °C, 43 A at 690 V and 55 °C. Rated operational power AC-3: 37 kW at 415 V, 30 kW at 380/400 V, 18.5 kW at 220/230/240 V. Screw terminals, dimensions 70 x 110 x 108 mm, 1.01 kg. Coil terminals IP20, main terminals IP10.
- AX65-30-00-85
The ABB AX65-30-00-85 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 110 mm deep, and 108 mm high, and weighs 1.01 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 55 °C, and rated operational power AC-3 is 37 kW at 415 V. Coil voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Terminals are screw type.
- AX65-30-00-88
The ABB AX65-30-00-88 is an AC contactor with three normally open main contacts and no auxiliary contacts. Its rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 55 °C, with rated operational power AC-3 of 37 kW at 415 V. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C). Main and auxiliary circuits are rated 690 V at 50 or 60 Hz. Screw terminals are used. Net dimensions are 70 mm width, 110 mm depth, and 108 mm height; net weight is 1.01 kg.
- AX65-30-11-26
The ABB AX65-30-11-26 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 55 °C, 55 A at 500 V and 55 °C, and 43 A at 690 V and 55 °C. Rated operational power AC-3 is 37 kW at 415 V and 30 kW at 380/400 V. Coil control voltage is 105 V at 50 Hz and 110 to 127 V at 60 Hz. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high; weight 1.01 kg. Screw terminals; coil terminals IP20 per IEC 60529.
- AX65-30-11-36
ABB AX65-30-11-36 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 82 mm wide, 110 mm deep, and 108 mm high, and weighs 1.05 kg. The main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 65 A at 415 V, 440 V, and 380/400 V, 55 A at 500 V, and 43 A at 690 V, all at 55 °C. Rated operational power AC-3 is 37 kW at 415 V, 440 V, 500 V, and 690 V, 30 kW at 380/400 V, and 18.5 kW at 220/230/240 V. Maximum mechanical switching frequency is 3600 cycles per hour.
- AX65-30-11-75
The ABB AX65-30-11-75 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 82 mm wide, 110 mm deep, and 108 mm high, and weighs 1.01 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 55 °C, and rated operational power AC-3 is 37 kW at 415 V. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C). Maximum mechanical switching frequency is 3600 cycles per hour.
- AX65-30-11-80
The ABB AX65-30-11-80 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 65 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, and 43 A at 690 V, all at 55 °C. Rated operational power AC-3 is 30 kW at 380/400 V and 37 kW at 415 V, 440 V, 500 V, and 690 V. The coil is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high; weight is 1.05 kg. Terminals are screw type.
- AX65-30-11-81
ABB AX65-30-11-81 AC contactor, manufacturer ID 1SBL371074R8111. Block-type design with 3 main contacts NO and 0 NC, plus 1 auxiliary contact NO and 1 NC. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current Ith is 125 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 55 °C, 55 A at 500 V, and 43 A at 690 V. Rated operational power AC-3 is 37 kW at 415 V and 30 kW at 380/400 V. Control circuit voltage is 24 V at 50 Hz and 60 Hz. Screw terminals; dimensions 82 mm width, 110 mm depth, 108 mm height; net weight 1.05 kg.