- AX65-30-00-80
The ABB AX65-30-00-80 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a 690 V main and auxiliary circuit at 50/60 Hz, with a control circuit voltage of 220 to 230 V at 50 Hz or 230 to 240 V at 60 Hz. Rated operational current AC-3 is 65 A at 415 V and 55 °C, and rated operational power AC-3 is 37 kW at 415 V. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high, with a net weight of 1.01 kg. Screw terminals are used, with main terminals rated IP10 and coil terminals IP20.
- AX65-30-00-81
The ABB AX65-30-00-81 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main and auxiliary circuit operational voltage of 690 V and a rated frequency of 50/60 Hz. Rated operational current AC-3 is 65 A at 415 V and 55 °C, 55 A at 500 V and 55 °C, and 43 A at 690 V and 55 °C. Rated operational power AC-3 is 30 kW at 380/400 V and 37 kW at 415 V, 440 V, 500 V, and 690 V. The coil operates at 24 V, 50/60 Hz. Dimensions are 70 mm wide, 110 mm deep, and 108 mm high, with a net weight of 1.01 kg. Terminals are screw type.
- AX65-30-00-83
ABB AX65-30-00-83 AC contactor, manufacturer ID 1SBL371074R8300. It has 3 main contacts NO, 0 main contacts NC, and 0 auxiliary contacts NO or NC. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated control circuit voltage is 48 V at 50 Hz and 48 V at 60 Hz. Conventional free-air thermal current is 125 A per IEC 60947-4-1, open contactors, 40 °C. Rated operational current AC-3 is 65 A at 415 V, 55 °C. Rated operational power AC-3 is 37 kW at 415 V and 30 kW at 380/400 V. Dimensions are 70 mm width, 110 mm depth, and 108 mm height; net weight 1.01 kg. Terminals are screw type. Coil terminals are IP20 and main terminals IP10 per IEC 60529, IEC 60947-1, and EN 60529.
- AX65-30-00-84
ABB AX65-30-00-84 AC contactor, manufacturer ID 1SBL371074R8400. Three main contacts NO, no auxiliary contacts. Rated operational voltage 690 V for main and auxiliary circuits at 50/60 Hz. Rated control circuit voltage 110 V at 50 Hz and 110 to 120 V at 60 Hz. Conventional free-air thermal current 125 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3: 65 A at 415 V and 55 °C, 43 A at 690 V and 55 °C. Rated operational power AC-3: 37 kW at 415 V, 30 kW at 380/400 V, 18.5 kW at 220/230/240 V. Screw terminals, dimensions 70 x 110 x 108 mm, 1.01 kg. Coil terminals IP20, main terminals IP10.
- AX65-30-00-85
The ABB AX65-30-00-85 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 110 mm deep, and 108 mm high, and weighs 1.01 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 55 °C, and rated operational power AC-3 is 37 kW at 415 V. Coil voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Terminals are screw type.
- AX65-30-00-88
The ABB AX65-30-00-88 is an AC contactor with three normally open main contacts and no auxiliary contacts. Its rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 55 °C, with rated operational power AC-3 of 37 kW at 415 V. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C). Main and auxiliary circuits are rated 690 V at 50 or 60 Hz. Screw terminals are used. Net dimensions are 70 mm width, 110 mm depth, and 108 mm height; net weight is 1.01 kg.
- AX65-30-11-26
The ABB AX65-30-11-26 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 55 °C, 55 A at 500 V and 55 °C, and 43 A at 690 V and 55 °C. Rated operational power AC-3 is 37 kW at 415 V and 30 kW at 380/400 V. Coil control voltage is 105 V at 50 Hz and 110 to 127 V at 60 Hz. Dimensions are 82 mm wide, 110 mm deep, and 108 mm high; weight 1.01 kg. Screw terminals; coil terminals IP20 per IEC 60529.
- AX65-30-11-36
ABB AX65-30-11-36 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 82 mm wide, 110 mm deep, and 108 mm high, and weighs 1.05 kg. The main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 65 A at 415 V, 440 V, and 380/400 V, 55 A at 500 V, and 43 A at 690 V, all at 55 °C. Rated operational power AC-3 is 37 kW at 415 V, 440 V, 500 V, and 690 V, 30 kW at 380/400 V, and 18.5 kW at 220/230/240 V. Maximum mechanical switching frequency is 3600 cycles per hour.