Product Model
OT63F4N1
Material Number
1SCA105370R1001
Manufacturer
ABB
Product ID
74141

Get a Free Quote

Request pricing and availability for OT63F4N1.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
Front IP20
Product Net Weight
0.31 kg
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)
(380 ... 415 V) 63 A (500 V) 63 A (690 V) 63 A
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 11 kW (400 ... 415 V) 22 kW (500 V) 22 kW (690 V) 15 kW
See all specifications

Product Highlights

  1. Pole Configuration: 4 poles with the fourth pole switched and simultaneous, positioned on the left side
  2. Mounting and Operation: Base mounting with front-operated mechanism on top of the switch
  3. Terminal Arrangement: Screw terminals accepting Cu cable cross-sections of 1.5 to 35 mm², with line terminals configurable as top in - bottom out or bottom in - top out
  4. Ratings: Rated insulation voltage 750 V, rated impulse withstand voltage 8 kV, conventional free-air thermal current 63 A at 40 °C, and fully enclosed conventional thermal current 63 A
  5. Operational Current and Power: AC-21A and AC-22A 63 A at 380 to 690 V, AC-23A 63 A at 380 to 415 V, 45 A at 500 V, and 20 A at 690 V, with AC-23A power up to 22 kW at 400 to 500 V
  6. Protection and Durability: Front IP20, pollution degree 3, mechanical durability 20,000 operations, and power loss 2.8 W per pole at rated operating conditions
  7. Standards and Compliance: IEC 60947-3, UL 508, and CSA C22.2 No. 14, with UL/CSA maximum operating voltage 600 V, ampere rating 60 A, and horsepower ratings up to 30 Hp three phase at 440 to 600 V
OT63F4N1

Product Information

Technical Specifications

Specifications for OT63F4N1

ParameterValue
Degree of ProtectionFront IP20
Environmental Information1SCC301263D0201
Pollution Degree3
Product Net Width70 mm
Product Net Height91.5 mm
Product Net Depth / Length72.5 mm
Product Net Weight0.31 kg
Cable Cross-SectionCu 1.5 ... 35 mm²
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 63 A
Conventional Thermal Current (Ithe)Fully Enclosed 63 A
Degree of ProtectionFront IP20
Distance Between PhasesStandard
Fourth Pole PositionLeft Side
Fourth Pole TypeSwitched - Simultaneous Function
Handle TypeKnob Handle and shaft not included
Lock TypeNo
Mechanical Durability20000
Mounting TypeBase mounting
Number of Poles4
Operating ModeFront operated
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out Bottom In - Top Out
Power Lossat Rated Operating Conditions per Pole 2.8 W
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)(380 ... 415 V) 63 A (500 V) 63 A (690 V) 63 A
ParameterValue
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 63 A (500 V) 63 A (690 V) 63 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 63 A (500 V) 45 A (690 V) 20 A
Rated Operational Power AC-23A (Pe)(220 ... 240 V) 11 kW (400 ... 415 V) 22 kW (500 V) 22 kW (690 V) 15 kW
Rated Operational VoltageMain Circuit 750 V
Rated Short-Circuit Making Capacity (Icm)(690 V) 2.1 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 1.5 kA
Special FunctionsNo
StandardsIEC 60947-3UL 508CSA C22.2 No. 14
Switches Operating MechanismMechanism on Top of the Switch
Terminal TypeScrew Terminals
Tightening Torqueacc. IEC 60947-1 2 N·m
Maximum Operating Voltage UL/CSA600 V
Ampere Rating60 A
Horsepower Rating UL/CSA(110 ... 120 V AC) Single Phase 2 Hp (240 V AC) Single Phase 7.5 Hp (440 ... 480 V AC) Single Phase 15 Hp (550 ... 600 V AC) Single Phase 15 Hp (220 ... 240 V AC) Three Phase 15 Hp (440 ... 480 V AC) Three Phase 30 Hp (550 ... 600 V AC) Three Phase 30 Hp
Tightening Torqueacc. IEC 60947-1 2 N·m
Tightening Torque UL/CSA18 in·lb
Object Classification CodeQ
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID1SCA105370R1001