Industrial Automation Parts. Prompt replies from real people.

ABB OT63FT4N2 Non-Fusible Disconnect Switch

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the ABB OT63FT4N2?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB OT63FT4N2 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
OT63FT4N2
Material Number
1SCA105393R1001
Manufacturer
ABB
Product ID
86691

Get a Free Quote

Request pricing and availability for OT63FT4N2.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
Front IP20
Product Net Weight
0.32 kg
Rated Conditional Short-Circuit Current (Inc)
(100 A fuse, ≤415 V) 50 kA (100 A fuse, 500 V) 100 kA (80 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 750 V
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 11 kW (400 ... 415 V) 22 kW (500 V) 22 kW (690 V) 15 kW
See all specifications

Product Highlights

  1. Electrical Ratings: 4-pole isolating switch rated 63 A at 40 °C, 750 V insulation voltage, 8 kV impulse withstand, and 50 kA conditional short-circuit current at 415 V with a 100 A fuse
  2. AC-23A Motor Switching: Rated operational power of 22 kW at 400–415 V and 500 V, 15 kW at 690 V, with AC-23A current of 63 A at 380–415 V, 45 A at 500 V, and 20 A at 690 V
  3. UL/CSA Ratings: 60 A, 600 V maximum, with single-phase horsepower ratings from 2 Hp at 110–120 V to 15 Hp at 550–600 V and three-phase ratings of 15 Hp at 220–240 V and 30 Hp at 440–600 V
  4. Connection and Mounting: Screw terminals accept Cu conductors from 1.5 to 35 mm², 2 N·m tightening torque, 10–12 mm stripping length, Pozidriv 2 screwdriver, and door mounting with front operation
  5. Construction and Standards: Front IP20, pollution degree 3, 20,000 mechanical operations, fourth pole switched on the right side, and compliance with IEC 60947-3, UL 508, and CSA C22.2 No. 14
OT63FT4N2

Product Information

Technical Specifications

Specifications for OT63FT4N2

ParameterValue
Degree of ProtectionFront IP20
Environmental Information1SCC301263D0201
Pollution Degree3
Product Net Width70 mm
Product Net Height72 mm
Product Net Depth / Length69 mm
Product Net Weight0.32 kg
Cable Cross-SectionCu 1.5 ... 35 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1x Cu 1.5…4 mm² Solid 1x Cu 1.5…6 mm² Flexible 1x Cu 1.5…35 mm² Stranded 1x Cu 1.5…35 mm²
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 63 A
Conventional Thermal Current (Ithe)Fully Enclosed 63 A
Degree of ProtectionFront IP20
Distance Between PhasesStandard
Fourth Pole PositionRight Side
Fourth Pole TypeSwitched - Simultaneous Function
Handle TypeHandle and shaft not included
Lock TypeNo
Mechanical Durability20000
Mounting TypeDoor mounting
Number of Poles4P
Operating ModeFront operated
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out Bottom In - Top Out
Power Lossat Rated Operating Conditions per Pole 2.8 W
Rated Conditional Short-Circuit Current (Inc)(100 A fuse, ≤415 V) 50 kA (100 A fuse, 500 V) 100 kA (80 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)(380 ... 415 V) 63 A (500 V) 63 A (690 V) 63 A
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 63 A (500 V) 63 A (690 V) 63 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 63 A (500 V) 45 A (690 V) 20 A
ParameterValue
Rated Operational Power AC-23A (Pe)(220 ... 240 V) 11 kW (400 ... 415 V) 22 kW (500 V) 22 kW (690 V) 15 kW
Rated Operational VoltageMain Circuit 750 V
Rated Short-Circuit Making Capacity (Icm)(690 V) 2.1 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 1.5 kA
Recommended Screw DriverMain Circuit Pozidriv 2
Special FunctionsNo
StandardsIEC 60947-3UL 508CSA C22.2 No. 14
Switches Operating MechanismMechanism on Top of the Switch
Terminal TypeScrew Terminals
Tightening Torqueacc. IEC 60947-1 2 N·m
Wire Stripping LengthMain Circuit 10-12 mm
Maximum Operating Voltage UL/CSA600 V
Ampere Rating60 A
Horsepower Rating UL/CSA(110 ... 120 V AC) Single Phase 2 Hp (240 V AC) Single Phase 7.5 Hp (440 ... 480 V AC) Single Phase 15 Hp (550 ... 600 V AC) Single Phase 15 Hp (220 ... 240 V AC) Three Phase 15 Hp (440 ... 480 V AC) Three Phase 30 Hp (550 ... 600 V AC) Three Phase 30 Hp
Wire Stripping LengthMain Circuit 10-12 mm
Recommended Screw DriverMain Circuit Pozidriv 2
Tightening Torqueacc. IEC 60947-1 2 N·m
Tightening Torque UL/CSA18 in·lb
Object Classification CodeQ
ETIM 8EC000216 - Switch disconnector
ETIM 9EC000216 - Switch disconnector (low voltage)
UNSPSC39122233
IDEA Granular Category Code (IGCC)5290 >> Disconnect switch
eClassV11.1 : 27371403
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)3601456
E-Number (Norway)4363541
E-Number (Sweden)3171085
Manufacturer ID1SCA105393R1001

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp