ABB OT63F8 8-Pole Non-Fused Disconnect Switch

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the ABB OT63F8?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB OT63F8 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
OT63F8
Material Number
1SCA105381R1001
Manufacturer
ABB
Product ID
83418

Get a Free Quote

Request pricing and availability for OT63F8.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
Front IP20
Product Net Weight
0.7 kg
Rated Conditional Short-Circuit Current (Inc)
(100 A fuse, ≤415 V) 50 kA (100 A fuse, 500 V) 100 kA (80 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 750 V
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 11 kW (400 ... 415 V) 22 kW (500 V) 22 kW (690 V) 15 kW
See all specifications

Product Highlights

  1. 8-Pole Configuration: Eight-pole isolating switch with switched fourth pole on the left and right side for simultaneous operation
  2. Electrical Ratings: 63 A conventional free-air thermal current at 40 °C, 750 V rated insulation voltage, 8 kV rated impulse withstand voltage, and 50 kA conditional short-circuit current at 415 V with a 100 A fuse
  3. Terminal and Wiring: Screw terminals accept Cu conductors from 1.5 to 35 mm², with 10 to 12 mm stripping length, 2 N·m tightening torque, and Pozidriv 2 screwdriver
  4. Mounting and Dimensions: Base mounting with front operation, 140 mm width, 91.5 mm height, 84.5 mm depth, and 0.7 kg net weight
  5. Standards and Protection: Complies with IEC 60947-3, UL 508, and CSA C22.2 No. 14, with front IP20 protection and pollution degree 3
OT63F8

Product Information

Technical Specifications

Specifications for OT63F8

ParameterValue
Degree of ProtectionFront IP20
Environmental Information1SCC301263D0201
Pollution Degree3
Product Net Width140 mm
Product Net Height91.5 mm
Product Net Depth / Length84.5 mm
Product Net Weight0.7 kg
Cable Cross-SectionCu 1.5 ... 35 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1x Cu 1.5…4 mm² Solid 1x Cu 1.5…6 mm² Flexible 1x Cu 1.5…35 mm² Stranded 1x Cu 1.5…35 mm²
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 63 A
Conventional Thermal Current (Ithe)Fully Enclosed 63 A
Degree of ProtectionFront IP20
Distance Between PhasesStandard
Fourth Pole PositionLeft and Right Side
Fourth Pole TypeSwitched - Simultaneous Function
Handle TypeKnob Handle and shaft not included
Lock TypeNo
Mechanical Durability20000
Mounting TypeBase mounting
Number of Poles8P
Operating ModeFront operated
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out Bottom In - Top Out
Power Lossat Rated Operating Conditions per Pole 2.8 W
Rated Conditional Short-Circuit Current (Inc)(100 A fuse, ≤415 V) 50 kA (100 A fuse, 500 V) 100 kA (80 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)(380 ... 415 V) 63 A (500 V) 63 A (690 V) 63 A
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 63 A (500 V) 63 A (690 V) 63 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 63 A (500 V) 45 A (690 V) 20 A
ParameterValue
Rated Operational Power AC-23A (Pe)(220 ... 240 V) 11 kW (400 ... 415 V) 22 kW (500 V) 22 kW (690 V) 15 kW
Rated Operational VoltageMain Circuit 750 V
Rated Short-Circuit Making Capacity (Icm)(690 V) 1.4 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 1.5 kA
Recommended Screw DriverMain Circuit Pozidriv 2
Special FunctionsNo
StandardsIEC 60947-3UL 508CSA C22.2 No. 14
Switches Operating MechanismMechanism on Top of the Switch
Terminal TypeScrew Terminals
Tightening Torqueacc. IEC 60947-1 2 N·m
Wire Stripping LengthMain Circuit 10-12 mm
Maximum Operating Voltage UL/CSA600 V
Ampere Rating60 A
Horsepower Rating UL/CSA(110 ... 120 V AC) Single Phase 2 Hp (240 V AC) Single Phase 7.5 Hp (440 ... 480 V AC) Single Phase 15 Hp (550 ... 600 V AC) Single Phase 15 Hp (220 ... 240 V AC) Three Phase 15 Hp (440 ... 480 V AC) Three Phase 30 Hp (550 ... 600 V AC) Three Phase 30 Hp
Wire Stripping LengthMain Circuit 10-12 mm
Recommended Screw DriverMain Circuit Pozidriv 2
Tightening Torqueacc. IEC 60947-1 2 N·m
Tightening Torque UL/CSA18 in·lb
Object Classification CodeQ
ETIM 8EC000216 - Switch disconnector
ETIM 9EC000216 - Switch disconnector (low voltage)
UNSPSC39122233
IDEA Granular Category Code (IGCC)5290 >> Disconnect switch
eClassV11.1 : 27371403
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)3601454
E-Number (Norway)4363572
Manufacturer ID1SCA105381R1001

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp