- DS201 C13 A30
ABB DS201 C13 A30 is a 1P+N leakage protection circuit breaker (RCBO) for single-phase circuits, with 13 A rated current and 30 mA rated residual current, Type A. Tripping characteristic C. Rated operational voltage 240 V AC according to IEC 60898-1; rated insulation voltage 500 V according to IEC/EN 60664-1; rated impulse withstand voltage 4 kV. Rated short-circuit capacity 6 kA; rated ultimate short-circuit breaking capacity 10 kA; rated service short-circuit breaking capacity 7.5 kA. Rated frequency 50 to 60 Hz. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Two-module DIN-rail mounting, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m. Ambient air temperature -25 to 55 °C. Degree of protection IP20/IP40.
- DS201 C13 A300
ABB DS201 C13 A300 is a 1P+N residual current circuit breaker with overcurrent protection, Type A residual current, C tripping characteristic, 13 A rated current, and 300 mA rated residual current. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and 50/60 Hz rated frequency. Short-circuit ratings include 10 kA Icu, 7.5 kA Ics, and 6 kA rated short-circuit capacity. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, two modular spacings, 35 mm width, screw terminals, 2.8 N·m tightening torque, and -25 to 55 °C operating ambient temperature. Manufacturer ID: 2CSR255180R3134.
- DS201 C16 A30
ABB DS201 C16 A30 leakage protection circuit breaker, 2-pole RCBO with one protected pole. Rated current 16 A, rated residual current 30 mA, Type A residual current, tripping characteristic C. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV; rated frequency 50 to 60 Hz. Rated short-circuit capacity 6 kA, rated ultimate short-circuit breaking capacity 10 kA, rated service short-circuit breaking capacity 7.5 kA. Complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, 2 modular spacings, 35 x 85 x 69 mm, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.
- DS201 C16 A300
ABB DS201 C16 A300 is a 1P+N residual current circuit breaker with overcurrent protection, rated 16 A, tripping characteristic C, and 300 mA Type A residual current. It is rated 240 V AC per IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated frequency 50 to 60 Hz. Short-circuit ratings include 6 kA rated short-circuit capacity, 10 kA Icu, 7.5 kA Ics, and 10 kA Inc. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device occupies two DIN-rail modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, weighs 200 g, and operates from -25 to 55 °C.
- DS201 C2 A300
ABB DS201 C2 A300 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type A residual current. Rated current is 2 A and rated residual current is 300 mA. It is rated 240 V AC according to IEC 60898-1, with 500 V rated insulation voltage according to IEC/EN 60664-1, 4 kV rated impulse withstand voltage, and 50 to 60 Hz rated frequency. Short-circuit ratings include 6 kA rated short-circuit capacity, 10 kA Icu and Inc, and 7.5 kA Ics. It has two poles, one protected pole, two modular spacings, and DIN-rail mounting. Dimensions are 35 mm width, 85 mm height, and 69 mm depth; net weight is 200 g. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 C20 A100
The ABB DS201 C20 A100 is a 1P+N RCBO combining overcurrent and earth fault protection in one device. It has a rated current of 20 A, C tripping characteristic, Type A residual current, and rated residual current of 100 mA. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA; rated service short-circuit breaking capacity (Ics) is 7.5 kA. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Electrical endurance is 10000 cycles and mechanical endurance 20000 cycles. It mounts on DIN rail, measures 35 mm x 85 mm x 69 mm, and weighs 200 g.
- DS201 C20 A30
The ABB DS201 C20 A30 is a 1P+N residual current breaker with overcurrent protection (RCBO) for single-phase circuits. It has a rated current of 20 A, rated residual current of 30 mA, Type A residual current, and C tripping characteristic. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA. It is rated 240 V AC per IEC 60898-1 at 50 to 60 Hz, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. It occupies two DIN-rail modules, measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g.
- DS201 C20 A30 UL
ABB DS201 C20 A30 UL is a leakage protection circuit breaker with a C tripping characteristic and Type A residual current detection. It is rated 20 A, 30 mA residual current, and 6 kA short-circuit capacity. Rated operational voltage is 240 V according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. It has two poles, one protected pole, and occupies two modular spacings on DIN rail. Screw terminals accept rigid and flexible conductors up to 25 mm², with 2.8 N·m tightening torque. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. Standards listed are IEC 61009-1, IEC 61009-2-1, UL 1053, UL 1077, and CSA C22.2 N0. 235.