- DS201 C16 A30
ABB DS201 C16 A30 leakage protection circuit breaker, 2-pole RCBO with one protected pole. Rated current 16 A, rated residual current 30 mA, Type A residual current, tripping characteristic C. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV; rated frequency 50 to 60 Hz. Rated short-circuit capacity 6 kA, rated ultimate short-circuit breaking capacity 10 kA, rated service short-circuit breaking capacity 7.5 kA. Complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, 2 modular spacings, 35 x 85 x 69 mm, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.
- DS201 C16 A300
ABB DS201 C16 A300 is a 1P+N residual current circuit breaker with overcurrent protection, rated 16 A, tripping characteristic C, and 300 mA Type A residual current. It is rated 240 V AC per IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated frequency 50 to 60 Hz. Short-circuit ratings include 6 kA rated short-circuit capacity, 10 kA Icu, 7.5 kA Ics, and 10 kA Inc. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device occupies two DIN-rail modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, weighs 200 g, and operates from -25 to 55 °C.
- DS201 C2 A300
ABB DS201 C2 A300 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type A residual current. Rated current is 2 A and rated residual current is 300 mA. It is rated 240 V AC according to IEC 60898-1, with 500 V rated insulation voltage according to IEC/EN 60664-1, 4 kV rated impulse withstand voltage, and 50 to 60 Hz rated frequency. Short-circuit ratings include 6 kA rated short-circuit capacity, 10 kA Icu and Inc, and 7.5 kA Ics. It has two poles, one protected pole, two modular spacings, and DIN-rail mounting. Dimensions are 35 mm width, 85 mm height, and 69 mm depth; net weight is 200 g. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 C20 A100
The ABB DS201 C20 A100 is a 1P+N RCBO combining overcurrent and earth fault protection in one device. It has a rated current of 20 A, C tripping characteristic, Type A residual current, and rated residual current of 100 mA. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA; rated service short-circuit breaking capacity (Ics) is 7.5 kA. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Electrical endurance is 10000 cycles and mechanical endurance 20000 cycles. It mounts on DIN rail, measures 35 mm x 85 mm x 69 mm, and weighs 200 g.
- DS201 C20 A30
The ABB DS201 C20 A30 is a 1P+N residual current breaker with overcurrent protection (RCBO) for single-phase circuits. It has a rated current of 20 A, rated residual current of 30 mA, Type A residual current, and C tripping characteristic. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA. It is rated 240 V AC per IEC 60898-1 at 50 to 60 Hz, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. It occupies two DIN-rail modules, measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g.
- DS201 C20 A30 UL
ABB DS201 C20 A30 UL is a leakage protection circuit breaker with a C tripping characteristic and Type A residual current detection. It is rated 20 A, 30 mA residual current, and 6 kA short-circuit capacity. Rated operational voltage is 240 V according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. It has two poles, one protected pole, and occupies two modular spacings on DIN rail. Screw terminals accept rigid and flexible conductors up to 25 mm², with 2.8 N·m tightening torque. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. Standards listed are IEC 61009-1, IEC 61009-2-1, UL 1053, UL 1077, and CSA C22.2 N0. 235.
- DS201 C20 A300
ABB DS201 C20 A300 is a 1P+N leakage protection circuit breaker (RCBO) with a rated current of 20 A and rated residual current of 300 mA, Type A. Tripping characteristic C. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV. Rated short-circuit capacity 6 kA; rated ultimate short-circuit breaking capacity 10 kA; rated service short-circuit breaking capacity 7.5 kA. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency 50 to 60 Hz. Two poles, one protected pole, two modular spacings, DIN-rail mounting. Dimensions 85 x 69 x 35 mm; net weight 200 g. Screw terminals, tightening torque 2.8 N·m. Ambient air temperature -25 to 55 °C. Degree of protection IP20/IP40.
- DS201 C20 AC100
The ABB DS201 C20 AC100 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type AC residual current. It is rated 20 A with a 100 mA rated residual current, 240 V rated operational voltage per IEC 60898-1, and 50 to 60 Hz. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity is 10 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Contact position is indicated red ON / green OFF, with a blue fault flag on the toggle. It mounts on DIN rail, occupies two modular spacings, measures 35 mm by 85 mm by 69 mm, and weighs 200 g. Terminal tightening torque is 2.8 N·m, wire stripping length 12 mm, and operating ambient air temperature is -25 to 55 °C.