- DS201 C20 A30
The ABB DS201 C20 A30 is a 1P+N residual current breaker with overcurrent protection (RCBO) for single-phase circuits. It has a rated current of 20 A, rated residual current of 30 mA, Type A residual current, and C tripping characteristic. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA. It is rated 240 V AC per IEC 60898-1 at 50 to 60 Hz, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. It occupies two DIN-rail modules, measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g.
- DS201 C20 A30 UL
ABB DS201 C20 A30 UL is a leakage protection circuit breaker with a C tripping characteristic and Type A residual current detection. It is rated 20 A, 30 mA residual current, and 6 kA short-circuit capacity. Rated operational voltage is 240 V according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. It has two poles, one protected pole, and occupies two modular spacings on DIN rail. Screw terminals accept rigid and flexible conductors up to 25 mm², with 2.8 N·m tightening torque. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. Standards listed are IEC 61009-1, IEC 61009-2-1, UL 1053, UL 1077, and CSA C22.2 N0. 235.
- DS201 C20 A300
ABB DS201 C20 A300 is a 1P+N leakage protection circuit breaker (RCBO) with a rated current of 20 A and rated residual current of 300 mA, Type A. Tripping characteristic C. Rated operational voltage 240 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV. Rated short-circuit capacity 6 kA; rated ultimate short-circuit breaking capacity 10 kA; rated service short-circuit breaking capacity 7.5 kA. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency 50 to 60 Hz. Two poles, one protected pole, two modular spacings, DIN-rail mounting. Dimensions 85 x 69 x 35 mm; net weight 200 g. Screw terminals, tightening torque 2.8 N·m. Ambient air temperature -25 to 55 °C. Degree of protection IP20/IP40.
- DS201 C20 AC100
The ABB DS201 C20 AC100 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type AC residual current. It is rated 20 A with a 100 mA rated residual current, 240 V rated operational voltage per IEC 60898-1, and 50 to 60 Hz. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity is 10 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Contact position is indicated red ON / green OFF, with a blue fault flag on the toggle. It mounts on DIN rail, occupies two modular spacings, measures 35 mm by 85 mm by 69 mm, and weighs 200 g. Terminal tightening torque is 2.8 N·m, wire stripping length 12 mm, and operating ambient air temperature is -25 to 55 °C.
- DS201 C20 AC30
The ABB DS201 C20 AC30 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO). It is rated 20 A with a C tripping characteristic and 30 mA Type AC residual current. Rated operational voltage is 240 V AC according to IEC 60898-1; rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) is 10 kA, and rated service short-circuit breaking capacity (Ics) is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device uses screw terminals, accepts conductors from 0.75 to 25 mm², mounts on DIN rail, and has two poles across two modular spacings. Net dimensions are 35 mm wide, 85 mm high, and 69 mm deep; net weight is 200 g. Operating ambient air temperature is -25 to 55 °C.
- DS201 C20 AC300
ABB DS201 C20 AC300 is a 1P+N residual current circuit breaker with overcurrent protection, rated 20 A and 300 mA residual current, tripping characteristic C, Type AC residual current. It is rated 240 V AC according to IEC 60898-1 and covers 50 to 60 Hz. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity Icu is 10 kA; rated service short-circuit breaking capacity Ics is 7.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device occupies two modular spacings on DIN rail, measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g. Operating ambient air temperature is -25 to 55 °C. Terminal tightening torque is 2.8 N·m.
- DS201 C20 APR100
The ABB DS201 C20 APR100 is a 1P+N residual current circuit breaker with overcurrent protection, rated 20 A with a C tripping characteristic and 100 mA Type A residual current. It is rated 240 V AC according to IEC 60898-1, with a rated short-circuit capacity of 6 kA, rated ultimate short-circuit breaking capacity of 10 kA, and rated impulse withstand voltage of 4 kV. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, occupies two modular spacings, and mounts on DIN rail. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. Dimensions are 35 mm width, 85 mm height, and 69 mm depth, with a net weight of 200 g.
- DS201 C20 APR30
ABB DS201 C20 APR30 leakage protection circuit breaker, 1P+N RCBO with one protected pole and two poles total. Rated current 20 A, rated residual current 30 mA, Type A residual current, tripping characteristic C. Rated operational voltage 240 V AC per IEC 60898-1; rated frequency 50 to 60 Hz. Rated short-circuit capacity 6 kA, rated ultimate short-circuit breaking capacity 10 kA, rated service short-circuit breaking capacity 7.5 kA. Complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.