- BC7-22-00-16
The ABB BC7-22-00-16 is a 4-pole mini contactor with 2 NO and 2 NC main contacts. It has a rated control circuit voltage of 48 V DC and a rated operational voltage of 690 V AC (main circuit) or 220 V DC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at both 40 °C and 55 °C for 690 V. Rated operational power AC-3 is 3 kW at 230 V three-phase and 5.5 kW at 400 V and 500 V three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, with a net weight of 0.175 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- BC7-30-01-01
The ABB BC7-30-01-01 is a 3-pole miniature AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The rated control circuit voltage is 24 V DC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 230 V and 690 V three-phase. The contactor is rated 690 V AC for the main circuit and offers screw terminals with IP20 protection on all terminals. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- BC7-30-01-03
ABB BC7-30-01-03 miniature AC contactor, 3-pole, with 3 NO main contacts and 1 NC auxiliary contact. Coil: 60 V DC control circuit voltage; operating limits 0.85 to 1.1 x Uc for DC supply at ambient temperature up to 55 °C. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C (220/240 V, 380/440 V); 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Dimensions 57.5 mm H x 52.5 mm W x 46.7 mm D; 0.175 kg. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- BC7-30-01-04
The ABB BC7-30-01-04 is a 3-pole mini contactor with 3 NO main contacts and 1 NC auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The control circuit is rated 110 to 125 V DC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for DC supply at temperatures up to 55 °C. Main circuit ratings include 690 V AC and 220 V DC, with AC-1 rated operational current of 20 A at 40 °C and AC-3 rated operational power of 5.5 kW at 400 V and 500 V for three-phase loads. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 and operates from -25 to +55 °C.
- BC7-30-01-05
ABB BC7-30-01-05 mini contactor, 3-pole, with 3 NO main contacts and 1 NC auxiliary contact. DC-operated control circuit at 220 to 240 V DC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated operational power AC-3: 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, 3 kW at 690 V three-phase. Dimensions 52.5 mm W x 57.5 mm H x 46.7 mm D; net weight 0.175 kg. Screw terminals, 9 mm stripping length, tightening torque 0.8 to 1.1 N·m. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- BC7-30-01-07
ABB BC7-30-01-07 mini contactor with manufacturer ID GJL1313001R0017. Three-pole device with 3 NO main contacts and 1 NC auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 12 V DC; coil operating limits 0.85 to 1.1 x Uc for DC supply at up to 55 °C. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C (220/240 V, 380/440 V); 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V. Dimensions 52.5 x 57.5 x 46.7 mm; net weight 0.175 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- BC7-30-01-1.4-81
The ABB BC7-30-01-1.4-81 is a 3-pole interface mini contactor with three normally open main contacts and one normally closed auxiliary contact. The rated control circuit voltage is 24 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Rated operational power is 5.5 kW at 400 V and 500 V three-phase AC-3, and 3 kW at 230 V and 690 V three-phase AC-3. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- BC7-30-01-16
The ABB BC7-30-01-16 is a 3-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. Its 48 V DC control coil operates within 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C, per IEC 60947-4-1. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; at 690 V it is 6 A at both temperatures. AC-3 rated power includes 3 kW at 230 V and 5.5 kW at 400 V and 500 V, three-phase. Dimensions are 52.5 mm W x 57.5 mm H x 46.7 mm D, weight 0.175 kg. Mechanical durability is 10,000,000 cycles. Terminals are IP20. DIN-rail mounting is TH35-15 or TH35-7.5 per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.