- BC7-30-01-03
ABB BC7-30-01-03 miniature AC contactor, 3-pole, with 3 NO main contacts and 1 NC auxiliary contact. Coil: 60 V DC control circuit voltage; operating limits 0.85 to 1.1 x Uc for DC supply at ambient temperature up to 55 °C. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C (220/240 V, 380/440 V); 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Dimensions 57.5 mm H x 52.5 mm W x 46.7 mm D; 0.175 kg. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- BC7-30-01-04
The ABB BC7-30-01-04 is a 3-pole mini contactor with 3 NO main contacts and 1 NC auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The control circuit is rated 110 to 125 V DC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for DC supply at temperatures up to 55 °C. Main circuit ratings include 690 V AC and 220 V DC, with AC-1 rated operational current of 20 A at 40 °C and AC-3 rated operational power of 5.5 kW at 400 V and 500 V for three-phase loads. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 and operates from -25 to +55 °C.
- BC7-30-01-05
ABB BC7-30-01-05 mini contactor, 3-pole, with 3 NO main contacts and 1 NC auxiliary contact. DC-operated control circuit at 220 to 240 V DC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated operational power AC-3: 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, 3 kW at 690 V three-phase. Dimensions 52.5 mm W x 57.5 mm H x 46.7 mm D; net weight 0.175 kg. Screw terminals, 9 mm stripping length, tightening torque 0.8 to 1.1 N·m. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- BC7-30-01-07
ABB BC7-30-01-07 mini contactor with manufacturer ID GJL1313001R0017. Three-pole device with 3 NO main contacts and 1 NC auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 12 V DC; coil operating limits 0.85 to 1.1 x Uc for DC supply at up to 55 °C. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C (220/240 V, 380/440 V); 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V. Dimensions 52.5 x 57.5 x 46.7 mm; net weight 0.175 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- BC7-30-01-1.4-81
The ABB BC7-30-01-1.4-81 is a 3-pole interface mini contactor with three normally open main contacts and one normally closed auxiliary contact. The rated control circuit voltage is 24 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Rated operational power is 5.5 kW at 400 V and 500 V three-phase AC-3, and 3 kW at 230 V and 690 V three-phase AC-3. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- BC7-30-01-16
The ABB BC7-30-01-16 is a 3-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. Its 48 V DC control coil operates within 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C, per IEC 60947-4-1. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; at 690 V it is 6 A at both temperatures. AC-3 rated power includes 3 kW at 230 V and 5.5 kW at 400 V and 500 V, three-phase. Dimensions are 52.5 mm W x 57.5 mm H x 46.7 mm D, weight 0.175 kg. Mechanical durability is 10,000,000 cycles. Terminals are IP20. DIN-rail mounting is TH35-15 or TH35-7.5 per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- BC7-30-01-2.4-51
The ABB BC7-30-01-2.4-51 is a 3-pole interface mini contactor with three normally open main contacts and one normally closed auxiliary contact. Its DC control circuit operates at 17 to 32 V DC. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV for both main and auxiliary circuits. Rated operational current AC-1 is 20 A at 40 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase. Mechanical durability is 10,000,000 cycles. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- BC7-30-01-2.4-54
ABB BC7-30-01-2.4-54 interface mini contactor, manufacturer ID GJL1313001R5014. Three-pole (3P) device with three main contacts NO and one auxiliary contact NC. Rated control circuit voltage 36 to 65 V DC. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V for both temperatures. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V. Mechanical durability 10,000,000 cycles. Dimensions 52.5 x 57.5 x 46.7 mm, net weight 0.175 kg. Ambient air temperature -20 to +55 °C in operation. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.