- BC7-30-01-1.4-81
The ABB BC7-30-01-1.4-81 is a 3-pole interface mini contactor with three normally open main contacts and one normally closed auxiliary contact. The rated control circuit voltage is 24 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Rated operational power is 5.5 kW at 400 V and 500 V three-phase AC-3, and 3 kW at 230 V and 690 V three-phase AC-3. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- BC7-30-01-16
The ABB BC7-30-01-16 is a 3-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. Its 48 V DC control coil operates within 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C, per IEC 60947-4-1. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; at 690 V it is 6 A at both temperatures. AC-3 rated power includes 3 kW at 230 V and 5.5 kW at 400 V and 500 V, three-phase. Dimensions are 52.5 mm W x 57.5 mm H x 46.7 mm D, weight 0.175 kg. Mechanical durability is 10,000,000 cycles. Terminals are IP20. DIN-rail mounting is TH35-15 or TH35-7.5 per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- BC7-30-01-2.4-51
The ABB BC7-30-01-2.4-51 is a 3-pole interface mini contactor with three normally open main contacts and one normally closed auxiliary contact. Its DC control circuit operates at 17 to 32 V DC. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV for both main and auxiliary circuits. Rated operational current AC-1 is 20 A at 40 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase. Mechanical durability is 10,000,000 cycles. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- BC7-30-01-2.4-54
ABB BC7-30-01-2.4-54 interface mini contactor, manufacturer ID GJL1313001R5014. Three-pole (3P) device with three main contacts NO and one auxiliary contact NC. Rated control circuit voltage 36 to 65 V DC. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V for both temperatures. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V. Mechanical durability 10,000,000 cycles. Dimensions 52.5 x 57.5 x 46.7 mm, net weight 0.175 kg. Ambient air temperature -20 to +55 °C in operation. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- BC7-30-01-F-01
The ABB BC7-30-01-F-01 is a 3-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.17 kg. The control circuit is rated 24 V DC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Main circuit ratings include 690 V AC, 220 V DC, and 20 A AC-1 at 40 °C. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase. Terminals are IP20. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- BC7-30-01-F-03
ABB BC7-30-01-F-03 mini contactor, three-pole (3 NO main contacts, 0 NC), with one auxiliary NC contact. Rated control circuit voltage is 60 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both temperatures. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Dimensions are 52.5 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.17 kg. Mechanical durability is 10,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- BC7-30-01-F-1.4-81
ABB BC7-30-01-F-1.4-81 mini contactor, an interface mini contactor with three poles and three normally open main contacts. It has one normally closed auxiliary contact and a 24 V DC control circuit. Rated operational voltage is 690 V AC for the main and auxiliary circuits, and 220 V DC for the main circuit. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V and 5.5 kW at 400 V and 500 V, three phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.17 kg. Standards include IEC/EN 60947-4-1.
- BC7-30-01-F-2.4-51
ABB AC contactor, display model BC7-30-01-F-2.4-51, manufacturer ID GJL1313003R5011. Interface mini contactor with 3 poles, 3 NO main contacts and 1 NC auxiliary contact. Control circuit rated 17 to 32 V DC; main circuit rated 690 V AC and 220 V DC, with 50 Hz, 60 Hz, and DC main circuit frequencies. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 230 V and 690 V three-phase. Dimensions are 52.5 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.17 kg. Mechanical durability is 10,000,000 cycles. Ambient operating temperature is -20 to +55 degrees C. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.