- BC7-30-01-F-1.4-81
ABB BC7-30-01-F-1.4-81 mini contactor, an interface mini contactor with three poles and three normally open main contacts. It has one normally closed auxiliary contact and a 24 V DC control circuit. Rated operational voltage is 690 V AC for the main and auxiliary circuits, and 220 V DC for the main circuit. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V and 5.5 kW at 400 V and 500 V, three phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.17 kg. Standards include IEC/EN 60947-4-1.
- BC7-30-01-F-2.4-51
ABB AC contactor, display model BC7-30-01-F-2.4-51, manufacturer ID GJL1313003R5011. Interface mini contactor with 3 poles, 3 NO main contacts and 1 NC auxiliary contact. Control circuit rated 17 to 32 V DC; main circuit rated 690 V AC and 220 V DC, with 50 Hz, 60 Hz, and DC main circuit frequencies. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 230 V and 690 V three-phase. Dimensions are 52.5 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.17 kg. Mechanical durability is 10,000,000 cycles. Ambient operating temperature is -20 to +55 degrees C. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- BC7-30-01-P-01
ABB BC7-30-01-P-01 mini contactor, 3-pole, with 3 NO main contacts and 1 NC auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 24 V DC; coil operating limits 0.85 to 1.1 x Uc at up to 55 °C per IEC 60947-4-1. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Rated operational current AC-1: 12 A at 220/240 V and 380/440 V, 6 A at 690 V. Dimensions 47.5 x 45.2 x 47.7 mm; weight 0.17 kg. Mechanical durability 10,000,000 cycles. Ambient operation -25 to +55 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- BC7-30-01-P-04
ABB BC7-30-01-P-04 mini contactor, 3-pole, with 3 NO main contacts and 1 NC auxiliary contact. Rated control circuit voltage is 110 to 125 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC or 220 V DC, with rated frequency 50 Hz, 60 Hz, or DC. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V (40 °C and 55 °C), and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V and 690 V, and 5.5 kW at 400 V and 500 V, three phase. Dimensions are 47.5 mm width, 45.2 mm height, 47.7 mm depth; net weight 0.17 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- BC7-30-01-P-07
The ABB BC7-30-01-P-07 is a 3-pole interface mini contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, and weighs 0.17 kg. The control circuit is rated 12 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Main and auxiliary circuits are rated 690 V AC, and rated impulse withstand voltage is 6 kV. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase. Mechanical durability is 10,000,000 cycles. Terminals are IP20. DIN-rail mounting per IEC 60715 is supported. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- BC7-30-01-P-1.4-81
ABB BC7-30-01-P-1.4-81 interface mini contactor, manufacturer ID GJL1313009R8011. Three-pole device with three NO main contacts and one NC auxiliary contact, 24 V DC control coil. Rated operational voltage is 690 V AC main and auxiliary circuits, 220 V DC main, 250 V DC auxiliary. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, 6 A at 690 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase, 3 kW at 230 V and 690 V. Dimensions 47.5 mm wide, 45.2 mm high, 47.7 mm deep; net weight 0.17 kg. DIN-rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L. Not CA6 or CAF6 mountable.
- BC7-30-01-P-16
ABB BC7-30-01-P-16 mini contactor, 3-pole, with 3 NO main contacts and 1 NC auxiliary contact. Rated control circuit voltage is 48 V DC. Rated operational power AC-3 is 5.5 kW at 400 V three-phase and 5.5 kW at 500 V three-phase. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V, at both 40 °C and 55 °C. Dimensions are 47.5 mm width, 45.2 mm height, 47.7 mm depth; net weight 0.17 kg. Terminals are IP20. DIN-rail mounting per IEC 60715. Mechanical durability is 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- BC7-30-01-P-2.4-51
The ABB BC7-30-01-P-2.4-51 is a 3-pole interface mini contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, and weighs 0.17 kg. The rated control circuit voltage is 17 to 32 V DC. Rated operational voltage is 690 V AC for the main and auxiliary circuits, 220 V DC for the main circuit, and 250 V DC for the auxiliary circuit. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.