- BC7-30-01-P-2.4-51
The ABB BC7-30-01-P-2.4-51 is a 3-pole interface mini contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, and weighs 0.17 kg. The rated control circuit voltage is 17 to 32 V DC. Rated operational voltage is 690 V AC for the main and auxiliary circuits, 220 V DC for the main circuit, and 250 V DC for the auxiliary circuit. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- BC7-30-10-01
The ABB BC7-30-10-01 is a 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. Its 24 V DC control coil operates within 0.85 to 1.1 x Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Rated operational voltage is 690 V AC for the main and auxiliary circuits, with a rated impulse withstand voltage of 6 kV. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. Mechanical durability is 10,000,000 cycles.
- BC7-30-10-03
The ABB BC7-30-10-03 is a 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. Its rated control circuit voltage is 60 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Rated operational voltage is 690 V AC for main and auxiliary circuits, and rated insulation voltage is 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Dimensions are 52.5 mm width, 57.5 mm height, and 46.7 mm depth, weighing 0.175 kg. Mechanical durability is 10,000,000 cycles. Terminal protection is IP20. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- BC7-30-10-04
The ABB BC7-30-10-04 is a 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The control circuit is rated 110 to 125 V DC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC, with a rated impulse withstand voltage of 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase. Terminals accept rigid conductors from 1 to 4 mm².
- BC7-30-10-07
The ABB BC7-30-10-07 is a 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. Its control circuit is rated 12 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Main and auxiliary circuits are rated 690 V AC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V. AC-3 rated power is 5.5 kW at 400 V and 500 V. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight is 0.175 kg.
- BC7-30-10-1.4-81
ABB BC7-30-10-1.4-81 interface mini contactor, manufacturer ID GJL1313001R8101. Three-pole contactor with three NO main contacts and one NO auxiliary contact, screw terminals. Rated control circuit voltage 24 V DC; coil operating limits 0.85 to 1.1 x Uc for DC supply at ambient temperature up to 55 °C. Rated operational current AC-1: 20 A at 220/240 V and 380/440 V at 40 °C, 16 A at 55 °C, 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V, 3 kW at 690 V. Dimensions 52.5 x 57.5 x 46.7 mm, 0.175 kg. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1. No CA6 or CAF6 mountable.
- BC7-30-10-16
The ABB BC7-30-10-16 is a miniature AC contactor with three normally open main contacts and one normally open auxiliary contact. It has a 48 V DC control coil and operates at 50/60 Hz on the main circuit. Rated operational power AC-3 is 3 kW at 230 V three-phase and 5.5 kW at 400 V or 500 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both temperatures. Dimensions are 52.5 mm W x 57.5 mm H x 46.7 mm D, weight 0.175 kg. Mechanical durability is 10,000,000 cycles. Terminals are IP20. Standards include IEC/EN 60947-4-1 and UL 60947-4-1.
- BC7-30-10-2.4-51
The ABB BC7-30-10-2.4-51 is a 3-pole interface mini contactor with three normally open main contacts and one normally open auxiliary contact. Its DC control circuit is rated 17 to 32 V DC, with coil operating limits per IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight is 0.175 kg. Mechanical durability is 10,000,000 cycles. Terminals are IP20.