- DDA802 A S-100/0.3
The ABB DDA802 A S-100/0.3 is a selective residual current device block with a rated residual current of 300 mA and a rated current of 100 A. It is a Type A device with two poles and a selective operating characteristic, providing an intentional tripping delay. It is suitable for use with S800S, S800N, S800C, and S800B circuit breakers. Rated voltage is 230 V AC, 240 V AC, and 400 V AC; rated operational voltage is 400/690 V. Rated frequency is 50 to 60 Hz. Rated impulse withstand voltage is 6 kV, rated insulation voltage is 690 V, and maximum surge current is 5 kA. Power loss is 7 W. Connecting capacity is rigid 6 to 50 mm² and flexible 6 to 70 mm². Ambient operating temperature is -25 to 60 °C. Degree of protection is IP2X. It conforms to IEC EN 60947-2 Ann. B.
- DDA802 A S-100/1
The ABB DDA802 A S-100/1 is a Type A residual current device block with a rated current of 100 A and rated residual current of 1000 mA. It is suitable for use with S800S, S800N, S800C, and S800B devices. It has two poles and a selective operating characteristic. Rated voltage is 230 V AC, 240 V AC, and 400 V AC; rated operational voltage is 400/690 V. Rated insulation voltage is 690 V, rated impulse withstand voltage is 6 kV, and maximum surge current is 5 kA. Rated frequency is 50 to 60 Hz, power loss is 7 W, and ambient operating temperature range is -25 to 60 degrees C. Degree of protection is IP2X. Standards: IEC EN 60947-2 Ann. B.
- DDA802 A S-63/0.3
ABB DDA802 A S-63/0.3 leakage protector, Type A residual current device for sinusoidal alternating and pulsating direct earth fault currents. Rated current 63 A, rated residual current 300 mA, selective operating characteristic. Rated voltage 230/240/400 V AC, rated operational voltage 400/690 V, rated insulation voltage 690 V, rated impulse withstand voltage 6 kV, rated frequency 50 to 60 Hz. Maximum surge current 5 kA, power loss 9 W, two poles. Standards: IEC EN 60947-2 Ann. B. Suitable for S800S, S800N, S800C and S800B. Connecting capacity: rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient temperature -25 to 60 °C. Degree of protection IP2X. Dimensions 81 mm x 108.2 mm x 82.3 mm, weight 300 g.
- DDA802 A S-63/1
ABB DDA802 A S-63/1 is a Type A residual current device block with selective operating characteristic and intentional tripping delay. It is suitable for use with S800S, S800N, S800C and S800B miniature circuit breakers. Rated current is 63 A and rated residual current is 1000 mA. Rated voltages are 230 V AC, 240 V AC and 400 V AC; rated operational voltage is 400/690 V. Rated insulation voltage is 690 V, rated impulse withstand voltage is 6 kV, and maximum surge current is 5 kA. Rated frequency is 50 to 60 Hz, power loss is 9 W, and it has 2 poles. Connecting capacity is rigid 6 to 50 mm² and flexible 6 to 70 mm². Ambient operating temperature is -25 to 60 °C. Degree of protection is IP2X. It conforms to IEC EN 60947-2 Ann. B.
- DDA802 A-100/0.3
ABB DDA802 A-100/0.3 leakage protector, identified by manufacturer ID 2CSB802101R3000. Type A residual current device, 2-pole, rated current 100 A, rated residual current 300 mA, instantaneous operating characteristic. Rated voltage 230 V AC, 240 V AC, 400 V AC; rated operational voltage 400/690 V; rated insulation voltage 690 V; rated impulse withstand voltage 6 kV; rated frequency 50 to 60 Hz. Maximum surge current 0.25 kA; power loss 7 W. Suitable for S800S, S800N, S800C and S800B. Standards: IEC EN 60947-2 Ann. B. Connecting capacity rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient temperature -25 to 60 °C. Degree of protection IP2X. Dimensions 81 mm width, 108.2 mm height, 82.3 mm depth; net weight 300 g.
- DDA802 A-100/0.5
ABB DDA802 A-100/0.5 leakage protector, manufacturer ID 2CSB802101R4000. Type A residual current device, 2-pole, rated current 100 A, rated residual current 500 mA, instantaneous operating characteristic. Rated voltages: 230 V AC, 240 V AC, 400 V AC; rated operational voltage 400/690 V; rated insulation voltage 690 V; rated impulse withstand voltage 6 kV. Rated frequency 50 to 60 Hz. Maximum surge current 0.25 kA. Power loss 7 W. Suitable for S800S, S800N, S800C and S800B. Standards: IEC EN 60947-2 Ann. B. Connecting capacity rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient temperature -25 to 60 °C. Degree of protection IP2X. Dimensions 81 mm width, 108.2 mm height, 82.3 mm depth; net weight 300 g.
- DDA802 A-63/0.03
ABB DDA802 A-63/0.03 leakage protector, manufacturer ID 2CSB802101R1630. Rated current 63 A, rated residual current 30 mA, Type A residual current, instantaneous operating characteristic, two poles. Rated voltage 230 V AC, 240 V AC, and 400 V AC; rated operational voltage 400/690 V; rated insulation voltage 690 V; rated impulse withstand voltage 6 kV; rated frequency 50 to 60 Hz. Maximum surge current 0.25 kA; power loss 9 W. Standards: IEC EN 60947-2 Ann. B. Suitable for S800S, S800N, S800C, and S800B. Connecting capacity rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient operating temperature -25 to 60 °C. Degree of protection IP2X. Dimensions 81 mm width, 108.2 mm height, 82.3 mm depth; net weight 300 g.
- DDA802 A-63/0.3
ABB DDA802 A-63/0.3 leakage protector, Type A residual current device. Rated current 63 A, rated residual current 300 mA, instantaneous operating characteristic, two poles. Rated voltage 230/240/400 V AC; rated operational voltage 400/690 V; rated insulation voltage 690 V; rated impulse withstand voltage 6 kV. Rated frequency 50 to 60 Hz. Maximum surge current 0.25 kA. Power loss 9 W. Connecting capacity: rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient operating temperature -25 to 60 °C. Degree of protection IP2X. Standards: IEC EN 60947-2 Ann. B. Suitable for S800S, S800N, S800C, S800B. Net dimensions 81 mm width, 108.2 mm height, 82.3 mm depth; net weight 300 g.