- DDA802 A-100/0.5
ABB DDA802 A-100/0.5 leakage protector, manufacturer ID 2CSB802101R4000. Type A residual current device, 2-pole, rated current 100 A, rated residual current 500 mA, instantaneous operating characteristic. Rated voltages: 230 V AC, 240 V AC, 400 V AC; rated operational voltage 400/690 V; rated insulation voltage 690 V; rated impulse withstand voltage 6 kV. Rated frequency 50 to 60 Hz. Maximum surge current 0.25 kA. Power loss 7 W. Suitable for S800S, S800N, S800C and S800B. Standards: IEC EN 60947-2 Ann. B. Connecting capacity rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient temperature -25 to 60 °C. Degree of protection IP2X. Dimensions 81 mm width, 108.2 mm height, 82.3 mm depth; net weight 300 g.
- DDA802 A-63/0.03
ABB DDA802 A-63/0.03 leakage protector, manufacturer ID 2CSB802101R1630. Rated current 63 A, rated residual current 30 mA, Type A residual current, instantaneous operating characteristic, two poles. Rated voltage 230 V AC, 240 V AC, and 400 V AC; rated operational voltage 400/690 V; rated insulation voltage 690 V; rated impulse withstand voltage 6 kV; rated frequency 50 to 60 Hz. Maximum surge current 0.25 kA; power loss 9 W. Standards: IEC EN 60947-2 Ann. B. Suitable for S800S, S800N, S800C, and S800B. Connecting capacity rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient operating temperature -25 to 60 °C. Degree of protection IP2X. Dimensions 81 mm width, 108.2 mm height, 82.3 mm depth; net weight 300 g.
- DDA802 A-63/0.3
ABB DDA802 A-63/0.3 leakage protector, Type A residual current device. Rated current 63 A, rated residual current 300 mA, instantaneous operating characteristic, two poles. Rated voltage 230/240/400 V AC; rated operational voltage 400/690 V; rated insulation voltage 690 V; rated impulse withstand voltage 6 kV. Rated frequency 50 to 60 Hz. Maximum surge current 0.25 kA. Power loss 9 W. Connecting capacity: rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient operating temperature -25 to 60 °C. Degree of protection IP2X. Standards: IEC EN 60947-2 Ann. B. Suitable for S800S, S800N, S800C, S800B. Net dimensions 81 mm width, 108.2 mm height, 82.3 mm depth; net weight 300 g.
- DDA802A-100/0.03 APR
ABB DDA802A-100/0.03 APR is a Type A residual current device block for use with S800S, S800N, S800C and S800B circuit breakers. It has a rated current of 100 A and a rated residual current of 30 mA, with an instantaneous APR high-immunity operating characteristic. Rated voltage Ur is 230 V AC, 240 V AC and 400 V AC; rated operational voltage is 400/690 V. Rated insulation voltage is 690 V and rated impulse withstand voltage is 6 kV. Maximum surge current is 3 kA and rated frequency is 50 to 60 Hz. Power loss is 7 W. It has 2 poles, IP2X protection, and operates from -25 to 60 °C. Standards: IEC EN 60947-2 Ann. B.
- DDA802A-63/0.03 APR
ABB DDA802A-63/0.03 APR is a Type A residual current device block for use with S800S, S800N, S800C, and S800B circuit breakers. It has a rated current of 63 A, rated residual current of 30 mA, and a rated frequency of 50 to 60 Hz. Rated voltages are 230 V AC, 240 V AC, and 400 V AC; rated operational voltage is 400/690 V, rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV. Maximum surge current is 3 kA. Operating characteristic is instantaneous (APR high immunity). It has 2 poles, 9 W power loss, IP2X protection, and an ambient operating temperature range of -25 to 60 °C. Connecting capacity is rigid 6 to 50 mm² and flexible 6 to 70 mm². Standards: IEC EN 60947-2 Ann. B. Net weight 300 g.
- DDA802AC-63/0.03
ABB DDA802AC-63/0.03 leakage protector, Type AC, rated residual current 30 mA, rated current 63 A, two poles, instantaneous operating characteristic. Rated voltage 230 V AC, 240 V AC, 400 V AC; rated operational voltage 400/690 V; rated insulation voltage 690 V; rated impulse withstand voltage 6 kV; rated frequency 50/60 Hz. Maximum surge current 0.25 kA; power loss 9 W. Standards: IEC EN 60947-2 Ann. B. Suitable for S800S, S800N, S800C, S800B. Connecting capacity rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient temperature -25 to 60 °C. Degree of protection IP2X. Width 4.5 modular spacings; net dimensions 81 mm width, 108.2 mm height, 82.3 mm depth; net weight 300 g.
- DDA802AC-63/0.3
ABB DDA802AC-63/0.3 leakage protector, 2-pole, rated current 63 A, rated residual current 300 mA, Type AC residual current, instantaneous operating characteristic. Rated voltage 230/240/400 V AC; rated operational voltage 400/690 V; rated insulation voltage 690 V; rated impulse withstand voltage 6 kV; rated frequency 50/60 Hz; maximum surge current 0.25 kA; power loss 9 W. Suitable for S800S, S800N, S800C and S800B. Standards: IEC EN 60947-2 Ann. B. Connecting capacity rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient temperature -25 to 60 °C. Degree of protection IP2X. Dimensions 81 mm width, 108.2 mm height, 82.3 mm depth; net weight 300 g.
- DDA803 A S-100/0.3
ABB DDA803 A S-100/0.3 leakage protector, manufacturer ID 2CSB803201R3000. Type A residual current device with selective operating characteristic, rated residual current 300 mA, rated current 100 A, three poles. Rated voltage 400 V AC, 415 V AC, 690 V AC; rated operational voltage 400/690 V; rated insulation voltage 690 V; rated impulse withstand voltage 6 kV. Maximum surge current 5 kA. Rated frequency 50 to 60 Hz. Power loss 10.5 W. Connecting capacity rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient temperature -25 to 60 °C. Degree of protection IP2X. Standards IEC EN 60947-2 Ann. B. Suitable for S800S, S800N, S800C, S800B. Dimensions 117 mm x 108.2 mm x 82.3 mm, 400 g.