Industrial Automation Parts. Prompt replies from real people.

ABB DDA802 A S-63/0.3 Leakage protector

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the ABB DDA802 A S-63/0.3?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB DDA802 A S-63/0.3 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
DDA802 A S-63/0.3
Material Number
2CSB802201R3630
Manufacturer
ABB
Product ID
69363

Get a Free Quote

Request pricing and availability for DDA802 A S-63/0.3.

More parts to source? Send your whole list in one enquiry

Key specifications

Rated Voltage (Ur)
230 V AC 240 V AC 400 V AC
Rated Operational Voltage
400/690 V
Rated Current (In)
63 A
Rated Frequency (f)
50 … 60 Hz
Degree of Protection
IP2X
Product Net Weight
300 g
See all specifications

Product Highlights

  1. Selective Protection: Selective operating characteristic with intentional tripping delay for coordination with downstream instantaneous devices
  2. Residual Current Type: Type A detection of sinusoidal alternating and pulsating direct earth fault currents
  3. Rated Residual Current: 300 mA sensitivity at 63 A rated current
  4. Electrical Ratings: 230/240/400 V AC rated voltage, 400/690 V operational voltage, 690 V insulation voltage, 6 kV impulse withstand, 50 to 60 Hz, 9 W power loss
  5. Mounting and Connection: 2-pole, 4.5 modular spacings, 81 mm width, rigid 6 to 50 mm² and flexible 6 to 70 mm² conductors, for S800S S800N S800C S800B MCBs
  6. Standards and Environment: IEC EN 60947-2 Ann. B, IP2X, -25 to 60 °C operating temperature
DDA802 A S-63/0.3

Product Information

Technical Specifications

Specifications for DDA802 A S-63/0.3

ParameterValue
StandardsIEC EN 60947-2 Ann. B
Type of Residual CurrentType A
Suitable ForS800S S800N S800C S800B
Rated Voltage (Ur)230 V AC 240 V AC 400 V AC
Rated Operational Voltage400/690 V
Rated Insulation Voltage (Ui)690 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Rated Current (In)63 A
Rated Residual Current300 mA
Maximum Surge Current5 kA
Leakage Current TypeA
Rated Frequency (f)50 … 60 Hz
Power Loss9 W
Number of Poles2
Operating CharacteristicSelective
Connecting CapacityRigid 6 … 50 mm² Flexible 6 … 70 mm²
Ambient Temperature-25...60 °C
Ambient Air TemperatureOperation -25...60 °C
Degree of ProtectionIP2X
ParameterValue
Environmental Informationdocument not needed
Short-Circuit Current Rating (SCCR)0.3 ... 0.3 A
Width in Number of Modular Spacings4.5
Product Net Width81 mm
Product Net Height108.2 mm
Product Net Depth / Length82.3 mm
Product Net Weight300 g
ETIM 8EC002297 - Residual current circuit breaker (RCCB) module
ETIM 9EC002297 - Residual current circuit breaker (RCCB) module
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2BBusiness To Business
CN885363030
eClassV11.0 : 27142210
Object Classification CodeF
Manufacturer ID2CSB802201R3630

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
-