Product Model
2857-534
Material Number
—
Manufacturer
WAGO
Product ID
50282

Get a Free Quote

Request pricing and availability for 2857-534.

More parts to source? Send your whole list in one enquiry

Key specifications

Rated voltage
300V
Rated voltage of the measurement circuit connections per EN 61010-2-030
AC 300 V
Protection type
IP20
Weight
63.9g
Ambient temperature (operation)
-40 … +70 °C
Test voltage (input/service interface)
3 kVAC; 60 Hz; 1 min
See all specifications

Product Highlights

  1. Configuration: DIP switch or software configuration, with adjustable hysteresis and 0 to 60 s rise/fall delay for the relay and digital output
  2. Input: Thermocouple input supporting Type J (-210 to 1200 °C) and Type K (-200 to 1372 °C), with switchable cold junction compensation and maximum transmission error of ±1 K
  3. Outputs: One changeover relay contact (AgNi + Au) rated up to AC 250 V and a digital output rated up to 100 mA, each with 1 or 2 adjustable switching thresholds
  4. Supply: 24 VDC nominal with ±30 % tolerance, current consumption ≤40 mA plus digital output current, commoned via lateral push-in jumper bars with a maximum total current of 6 A
  5. Connection and mounting: Push-in CAGE CLAMP® connection with picoMAX® 5.0 connector, 0.2 to 2.5 mm² (24 to 12 AWG) conductors, 9 to 10 mm strip length, and DIN-35 rail mounting
  6. Ratings and environment: 300 V rated voltage, AC 300 V measurement circuit per EN 61010-2-030, CAT II input, IP20, reinforced insulation between input/supply/service interface and relay output, and -40 to +70 °C operating temperature
2857-534

Product Information

Technical Specifications

Specifications for 2857-534

ParameterValue
NoteThis product is supplied with 24 VDC, which can be commoned using lateral push-in type jumper bars: (6.1) US+ (BR) and (6.2) GND 2 (BR). With this variant, it is necessary to ensure that the maximum permissible total current of 6 A is not exceeded.
Rated voltage300V
Rated voltage of the measurement circuit connections per EN 61010-2-030AC 300 V
Measurement category per EN/UL 61010-2-030CAT II (input)
Note on insulation parametersTemperature sensors are not intended for use in dangerous circuits, provided the external temperature sensors used do not have basic insulation in accordance with EN/UL 61010-1 (300 VAC; overvoltage category II; pollution degree 2).
Protection typeIP20
Connection technologyPush-in CAGE CLAMP®
WAGO connector picoMAX® 5.0
Solid conductor0.2 2.5 m㎡/ 24 12 AWG
Fine-stranded conductor0.2 2.5 m㎡/ 24 12 AWG
Strip length9 10 mm / 0.35 0.39 inches
Width12.5 mm / 0.492 inches
Height110 mm / 4.331 inches
Depth from upper-edge of DIN-rail107 mm / 4.213 inches
Mounting typeDIN-35 rail
Fire load1.573MJ
Weight63.9g
Ambient temperature (operation)-40 … +70 °C
Ambient temperature (storage)-40 … 85 °C
Temperature range of connection cable≤ (Tambient+ 10 K)
Temperature range of connection cable (UL)80°C
Conformity markingCE
EMC immunity to interferenceEN 61000-6-2; EN 61326-2-3; EN 50121-3-2
EMC emission of interferenceEN 61000-6-4; EN 61326-2-3; EN 50121-3-2
Standards/specificationsEN 61010-1
eCl@ss 10.027-37-18-10
eCl@ss 9.027-37-18-10
ETIM 9.0EC001446
ETIM 8.0EC001446
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typebag
Country of originDE
GTIN4055143242318
Customs tariff number90303370000
CAS-No.1303-86-2
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)601bb33b-84cc-4805-b720-81f12c38c72c
SCIP notification number (Belgium)131209b7-ac71-4ce7-9b2f-c117badec519
SCIP notification number (Bulgaria)7c391072-6a84-41c0-a488-1eed30619da2
SCIP notification number (Czech Republic)d1772c11-7a5d-49f4-8bb4-425bbedd445f
SCIP notification number (Denmark)cfa32983-cc33-4189-b84e-a8b7c38e9bcd
SCIP notification number (Finland)5a251d21-3cd4-4150-8b9a-2dbe4ec1814c
SCIP notification number (France)d428f471-7411-4cc1-9954-e2e708d38bac
ParameterValue
SCIP notification number (Germany)b09e21e7-8662-4ee1-ac5a-dcad6c89462f
SCIP notification number (Hungary)38a2a8e6-be31-466e-a297-d4ed34448198
SCIP notification number (Italy)76a372f1-e64e-48fc-aa2a-513cbdd7d1f7
SCIP notification number (Netherlands)c7fe09a0-961d-444e-bccb-b777383080e3
SCIP notification number (Poland)ef7bea4e-4cc5-4c67-a93e-8f9ee40db738
SCIP notification number (Romania)2fa777e0-ce5b-4d0f-9b8d-8e5b77843923
SCIP notification number (Sweden)6bc78593-b9a6-44e7-b529-4a5eada11443
Configuration optionsDIP switch
Input signal typeTC sensors
Sensor types (TC)Type J
Temperature measurement range (TC)-210 1200 °C (Type J); -200 1372 °C (Type K)
Cold junction compensationOn/Off (Default: On)
Cold junction error3 K (typ. 2 K )
Switching voltage (DO) max.Supply voltage (applied): −0.3 V
Continuous current (DO) max.100 mA (no internal restriction)
Number of switching thresholds (DO)1 or 2 (adjustable)
Configurable rise/fall delay time (DO)0 … 60 s (via software)
Dielectric strength (open contact) (AC, 1 min)1 kVrms
Number of changeover contacts1
Contact material (relay)AgNi + Au
Switching Voltage, Max.AC 250 V
Pull-in time (typ.)8ms
Drop-out time (typ.)4ms
Bounce time (typ.)8ms
Number of switching thresholds (relay)1 or 2 (adjustable)
Configurable rise/fall delay time (relay)0 … 60 s (via software)
Software filter (adjustable)Moving average value (filter level: 30)
HysteresisAdjustable via DIP switch or software
Step response (typ.)60 ms (cold junction compensation (Off)); 360 ms (Cold junction compensation (ON))
Transmission error (max.)± 1 K
Temperature coefficient≤ 0.01 %/K
Power supply type24 VDC
Nominal supply voltage USDC 24 V
Supply voltage range±30 %
Current consumption at nominal supply voltage≤ 40 mA (+ IDO)
Test voltage (input/relay output/supply)4 kVAC; 60 Hz; 1 min
Test voltage (input/service interface)3 kVAC; 60 Hz; 1 min
Test voltage (relay output/service interface)4 kVAC; 60 Hz; 1 min
Test voltage (supply/service interface)2.5 kVAC; 60 Hz; 1 min
Overvoltage categoryII
Pollution degree2
Insulation type (input, supply and service interface/relay output)Reinforced insulation (safe isolation)
Insulation type (input/supply/service interface)Basic insulation

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.