- 855-1700/032-000
The WAGO 855-1700/032-000 is a plug-in current transformer for the WAGO I/O System, intended only for use with WAGO 750 Series 3-Phase Power Measurement Modules. It measures current with a 32 A primary rated current and 0.32 A secondary rated current at 50 to 60 Hz, accuracy class 0.5, and 0.01 VA rated power. The closed current transformer provides a 5.0 mm measurement conductor feedthrough and accepts 0.2 to 1.5 mm2 (24 to 14 AWG) conductors via push-in CAGE CLAMP connection and a picoMAX 3.5, 2091-1122 connector. It measures 17 mm wide, 34 mm high, and 23 mm deep, weighs 11 g, and operates from -10 to +55 °C. Protection is IP20; test voltage is AC 3 kV at 50 Hz for 1 min.
- 855-1851/350-000
WAGO 855-1851/350-000 is a current and voltage tap for 185 mm² conductors, with 350 A primary rated current, 1 A secondary rated current, and accuracy class 0.5. It mounts via the jumper slot of a 2-conductor high-current through terminal block (285-1185; 285-1184) for DIN-rail mounting. Rated voltage is AC 400 V; rated frequency 50 … 60 Hz; rated power 0.2 VA. The voltage path uses a 2 A; 450 V; F; 70 kA; 5 x 25 mm fuse (WAGO 855-8020). Dimensions are 32 mm width, 84 mm height, 60 mm depth; weight 144 g. Operation is -25 … +70 °C at up to 2000 m altitude. Conforms to EN 61869-2.
- 855-2701/035-001
WAGO 855-2701/035-001 plug-in current transformer, closed type, for current measurement. Primary rated current 35 A, secondary rated current 1 A, rated power 0.2 VA, accuracy class 1, rated frequency 50 to 60 Hz. Rated continuous thermal current 100 percent, rated short-time thermal current 60 x IN for 1 s, rated surge current 2.5 x Ith. Highest voltage for equipment Um AC 720 Vrms; test voltage AC 3 kV at 50 Hz for 1 min. Feedthrough for measurement conductor 7.5 mm. Push-in CAGE CLAMP connection, picoMAX 3.5 connector 2091-1122, strip length 8 to 9 mm, solid and fine-stranded conductors 0.2 to 1.5 mm2 (24 to 14 AWG). IP20, insulation class E, PA 66 housing. Dimensions 27 x 46 x 23 mm, weight 48.4 g. Operating temperature -10 to +55 C, storage -20 to +70 C, relative humidity 5 to 85 percent without condensation, altitude up to 2000 m. CE, EN 61869-1.
- 855-2701/064-001
WAGO 855-2701/064-001 plug-in current transformer, 64 A primary, 1 A secondary, rated frequency 50 … 60 Hz, accuracy class 1, rated power 0.2 VA. Closed current transformer with 7.5 mm feedthrough for the measurement conductor. Push-in CAGE CLAMP® connection; WAGO connector picoMAX® 3.5, 2091-1122; strip length 8 … 9 mm; solid and fine-stranded conductors 0.2 … 1.5 mm² (24 … 14 AWG). Dimensions 27 mm W x 46 mm H x 23 mm D; PA 66 housing; weight 44 g. IP20; insulation class E; highest voltage for equipment Um AC 720 Vrms; test voltage AC 3 kV, 50 Hz, 1 min. Ambient temperature -10 … +55 °C operation, -20 … +70 °C storage; relative humidity 5 … 85 % without condensation; operating altitude up to 2000 m. CE; EN 61869-1.
- 855-3001/060-003
WAGO 855-3001/060-003 split-core current transformer, suspended mounting, for current measurement. Primary rated current 60 A; secondary rated current 1 A; rated power Sr 0.2 VA; accuracy class 3. Rated frequency 50 … 60 Hz. Rated continuous thermal current Icth 100 %; rated short-time thermal current Ith 60 x IN/ 1 s; rated surge current Idyn 2.5 x Ith. Highest voltage for equipment Um AC 720 Vrms. Test voltage AC 6 kV, 50 Hz, 1 min. Feedthrough for measurement conductor Ø 18 mm. Cable 2 x 0.5 mm2, fine-stranded, 3 m; brown = S1, blue = S2. Dimensions 48 mm x 50.4 mm x 36 mm; weight 240 g. Ambient temperature -10 … +55 °C operation, -20 … +70 °C storage; relative humidity 5 85 % without condensation; operating altitude max. 2000 m. IP20; CE; EN 61869-1.
- 855-3001/100-003
WAGO 855-3001/100-003 split-core current transformer for current measurement, suspended mounting. Primary rated current 100 A, secondary rated current 1 A, rated power 0.2 VA, accuracy class 3, rated frequency 50 … 60 Hz. Measurement conductor feedthrough Ø 18 mm. Test voltage AC 6 kV; 50 Hz; 1 min. Highest voltage for equipment Um AC 720 Vrms. Rated continuous thermal current Icth 100 %, rated short-time thermal current Ith 60 x IN/ 1 s, rated surge current Idyn 2.5 x Ith. 3 m cable, 2 x 0.5 mm² fine-stranded, brown = S1, blue = S2. IP20, dimensions 48 x 50.4 x 36 mm, 240 g. Ambient temperature -10 … +55 °C operation, -20 … +70 °C storage, 5 85 % relative humidity without condensation, altitude up to 2000 m. Conforms to EN 61869-1, CE marked.
- 855-3001/200-001
WAGO 855-3001/200-001 split-core current transformer for current measurement, with a primary rated current of 200 A and a secondary rated current of 1 A. Rated power Sr is 0.2 VA and accuracy class is 1. Rated frequency is 50 … 60 Hz. The measurement conductor feedthrough is Ø 18 mm. The cable is 3 m, 2 x 0.5 mm2 fine-stranded, with brown = S1 and blue = S2. Dimensions are 48 mm width, 50.4 mm height, and 36 mm depth; weight is 10 g. Operation is -10 … +55 °C, storage -20 … +70 °C, relative humidity 5 85 % without condensation, and maximum operating altitude 2000 m. Protection type is IP20. Test voltage is AC 6 kV; 50 Hz; 1 min. Highest voltage for equipment Um is AC 720 Vrms. Conformity marking is CE; standards/specifications include EN 61869-1.
- 855-3001/250-001
WAGO 855-3001/250-001 split-core current transformer for current measurement, with a 250 A primary rated current and 1 A secondary rated current. Rated power is 0.2 VA at accuracy class 1, rated frequency 50 to 60 Hz. The measurement conductor feedthrough is Ø 18 mm. The unit measures 48 mm wide, 50.4 mm high, and 36 mm deep, weighs 237 g, and mounts suspended. It is IP20 rated, with a highest voltage for equipment Um of AC 720 Vrms and a test voltage of AC 6 kV at 50 Hz for 1 min. Operation is -10 to +55 °C; storage is -20 to +70 °C. The 3 m cable is 2 x 0.5 mm2 fine-stranded, brown = S1 and blue = S2. Conforms to EN 61869-1 and carries the CE marking.