- 750-661/000-004
WAGO 750-661/000-004 is a fail-safe 4-channel digital input module with voltage signal type 24 VDC and 4 fail-safe inputs with test pulse. It supports PROFIsafe V2.6 (PROFINET) and V2.4 (PROFIBUS, PROFINET); the PROFIsafe address is adjustable via DIP switch or engineering software. Input characteristic is Type 1 per IEC 61131, with typical input current 3 mA per channel at signal 1 and maximum signal frequency 50 Hz. Achievable safety classes are SIL 3, Category 4, PLe two-channel, and SIL 2, Category 2, PLd one-channel, per IEC 61508-1 to -7, EN ISO 13849-1, and EN 62061. Field supply is 24 VDC SELV/PELV (-25 to +30%) via power jumper contacts; system supply is 5 VDC via data contacts, drawing 120 mA. Connection is 8 x CAGE CLAMP, DIN-35 rail mounting, 12 mm wide.
- 750-662/000-003
WAGO 750-662/000-003 is a fail-safe 8-channel digital input module for PROFIsafe V2 networks. It provides eight clock-sensitive, voltage-type inputs rated 24 VDC, each a fail-safe input with test pulse; typical input current per channel at signal 1 is 2.2 mA, and maximum signal frequency is 50 Hz. The PROFIsafe address is adjustable via DIP switch or engineering software. Achievable safety classes are SIL 3, Category 4, PL e, per IEC 61508-1 to -7, EN ISO 13849-1, and EN 62061. System supply is 5 VDC via data contacts, drawing 148 mA; field supply is 24 VDC SELV/PELV (-15 to +20 percent) via power jumper contacts rated 10 A. Wiring uses 16 CAGE CLAMP connections for 0.08 to 2.5 mm2 (28 to 14 AWG), strip length 8 to 9 mm. Dimensions are 24 x 100 x 67.8 mm, DIN-35 rail mounting. End of sale was 2023-06-30.
- 750-662/000-004
WAGO 750-662/000-004 is a fail-safe 8-channel digital input module for PROFIsafe networks. It supports PROFIsafe V2.6 (PROFINET) and V2.4 (PROFIBUS, PROFINET), with the address adjustable via DIP switch or engineering software. Inputs are 24 VDC, Type 1 per IEC 61131, each drawing typically 3 mA, with a maximum signal frequency of 50 Hz. Sensor connection is 8 x fail-safe input with test pulse. Achievable safety classes are SIL 3, Category 4, PLe (two-channel) and SIL 2, Category 2, PLd (one-channel), per IEC 61508-1 -7, EN ISO 13849-1, and EN 62061. Field supply is 24 VDC SELV/PELV (-25 +30 %); system supply is 5 VDC via data contacts. Wiring uses 16 x CAGE CLAMP®; mounting is DIN-35 rail; width is 24 mm.
- 750-663/000-003
WAGO 750-663/000-003 is an intrinsically safe 4-channel digital input module for the WAGO I/O System 750, with 24 VDC voltage signal type and PROFIsafe V2 protocol. Each channel is a fail-safe input with test pulse; input current is typically 3 mA at signal 1, maximum signal frequency 50 Hz, and the input filter is parameterizable channel by channel from 0 to 200 ms. The module requires an Ex i 24 VDC power supply, such as 750-606 or 750-625/000-001. Safety data: Uo = 27.3 V, Io = 23 mA, Po = 157 mW, linear characteristic curve. Achievable risk reduction is SIL 3 per IEC 61508, IEC 61511, and IEC 62061, and Cat. 4, PL e per EN ISO 13849. Dimensions are 24 mm wide, 100 mm high, and 67.8 mm deep.
- 750-666/000-003
WAGO 750-666/000-003 is a fail-safe digital input/output module for PROFIsafe V2 networks. It provides four fail-safe digital inputs with test pulse and two fail-safe power outputs with test pulse, six channels total. Inputs are clock-sensitive, rated 24 VDC, with typical 2.2 mA current per channel at signal 1 and maximum signal frequency 50 Hz. Outputs are short-circuit-protected, 10 A per channel and 20 A per module, with maximum switching frequency 50 Hz for resistive loads and 0.1 Hz for inductive loads. The PROFIsafe address is adjustable via DIP switch or engineering software. Achievable safety classes are SIL 3, Category 4, PL e, per IEC 61508-1 to -7, EN ISO 13849-1, and EN 62061. Field supply is 24 VDC (-15 to +30 percent). Connection is via 15 x CAGE CLAMP; mounting is DIN-35 rail.
- 750-666/000-004
The WAGO 750-666/000-004 is a fail-safe digital input/output module with four fail-safe inputs (test pulse) and two fail-safe power outputs (test pulse), six channels total. Inputs are 24 VDC, Type 1 per IEC 61131, 3 mA typical per channel, maximum signal frequency 50 Hz. Output current is 2 A per channel for O1/O2 (Pilot Duty/DC13) and 10 A for other applications, with derating of 10 A at 40 °C and 6 A at 55 °C; module output current is 20 A. Field supply is 24 VDC SELV/PELV. Protocols are PROFIsafe V2.6 (PROFINET) and V2.4 (PROFIBUS, PROFINET). Achievable safety classes are SIL 3, Category 4, PLe (two-channel) and SIL 2, Category 2, PLd (one-channel), per IEC 61508-1 to -7, EN ISO 13849-1, and EN 62061.
- 750-667/000-003
WAGO 750-667/000-003 is a fail-safe digital I/O module with 4 digital inputs and 4 digital outputs, 8 channels total. Inputs are clock-sensitive, 24 VDC, with 2.2 mA typical input current per channel and a maximum signal frequency of 50 Hz; sensor connection is 4 x fail-safe input with test pulse. Outputs are short-circuit-protected power outputs rated 2 A per channel and 8 A per module, with 4 x fail-safe output with test pulse; maximum switching frequency is 50 Hz for resistive load and 0.1 Hz for inductive load. Field supply is 24 VDC SELV/PELV (-15 +20 %). Achievable safety classes are SIL 3, Category 4, PL e, per IEC 61508-1 -7, EN ISO 13849-1, and EN 62061. Protocol: PROFIsafe V2. Wiring is 16 x CAGE CLAMP, 24 mm wide, DIN-35 rail mounting.
- 750-667/000-004
WAGO 750-667/000-004 is a fail-safe digital I/O module with 4 digital inputs and 4 digital outputs. Inputs are fail-safe with test pulse, Type 1 per IEC 61131, 24 VDC, typical input current 3 mA per channel at signal 1, maximum signal frequency 50 Hz. Outputs are fail-safe power outputs with test pulse, 2 A per channel, 8 A per module, short-circuit-protected; maximum switching frequency is 50 Hz for resistive load, 0.1 Hz for inductive load, and 0.1 Hz for capacitive load. Field supply is 24 VDC SELV/PELV (-25 +20 %) via power jumper contacts. Achievable safety classes are SIL 3, Category 4, PLe (two-channel) and SIL 2, Category 2, PLd (one-channel), per IEC 61508-1 -7, EN ISO 13849-1, EN 62061. Connection is 16 x CAGE CLAMP, 0.08 to 2.5 mm2 (28 to 14 AWG), strip length 8 to 9 mm. Mounting is DIN-35 rail; width 24 mm.