Industrial Automation Parts. Prompt replies from real people.

WAGO 750-667/000-004 Controllers Bus Couplers I/O

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/27/2026

Q1Can you supply the WAGO 750-667/000-004?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 750-667/000-004 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
750-667/000-004
Material Number
—
Manufacturer
WAGO
Product ID
45597

Get a Free Quote

Request pricing and availability for 750-667/000-004.

More parts to source? Send your whole list in one enquiry

Key specifications

Protocols
PROFIsafe V2.6 (PROFINET) and V2.4 (PROFIBUS, PROFINET)
Signal type (voltage)
24 VDC
Signal frequency (max.)
50Hz
Output current per channel
2A
Supply voltage (system)
5 VDC; via data contacts
Number of incoming power jumper contacts
2
See all specifications

Product Highlights

  1. Safety Ratings: Achieves SIL 3, Category 4, PLe in two-channel configuration and SIL 2, Category 2, PLd in one-channel configuration per IEC 61508-1 to -7, EN ISO 13849-1, and EN 62061
  2. Digital Inputs: 4 fail-safe inputs with test pulse, 24 VDC, Type 1 per IEC 61131, typical 3 mA per channel at signal 1, maximum signal frequency 50 Hz
  3. Digital Outputs: 4 fail-safe power outputs with test pulse, 2 A per channel and 8 A per module, short-circuit-protected, maximum switching frequency 50 Hz for resistive loads and 0.1 Hz for inductive or capacitive loads
  4. Communication and Addressing: PROFIsafe V2.6 over PROFINET and V2.4 over PROFIBUS or PROFINET, with address adjustable via DIP switch or engineering software
  5. Indicators: Green/red LEDs A-D for status/error of inputs I1-I4, green/red LEDs I-M for status/error of outputs O1-O4, red LED E for group error, and green/red LEDs F-H for diagnostics
  6. Mounting and Connections: DIN-35 rail mounting, 16 CAGE CLAMP connections for inputs/outputs accepting 0.08-2.5 mm2 (28-14 AWG) conductors with 8-9 mm strip length, and a fixed pluggable connector
750-667/000-004

Product Information

Technical Specifications

Specifications for 750-667/000-004

ParameterValue
ProtocolsPROFIsafe V2.6 (PROFINET) and V2.4 (PROFIBUS, PROFINET)
Configuration optionsPROFIsafe address adjustable via DIP switch or engineering software
IndicatorsLED (A-D) green/red: Status/Error I1 I4; LED (I-M) green/red: Status/error O1 O4; LED (E) red: Group error; LED (F-H) green/red: Diagnostics
Number of Channels8
Pluggable connectorfixed
Number of digital inputs4
Signal typeVoltage
Signal type (voltage)24 VDC
Sensor connection4 x (Fail-safe input with test pulse)
Input characteristicType 1 per IEC 61131
Input current per channel for signal (1) typ.3mA
Signal frequency (max.)50Hz
Output current per channel2A
Number of digital outputs4
Output currentshort-circuit-protected
Output current (module)8A
Actuator connection4 x (fail-safe output with test pulse)
Output circuit designPower outputs
Switching frequency (max.)50 Hz; Resistive load
Switching frequency (max.) (2)0.1 Hz; Inductive load
Switching frequency (max.) (3)0.1 Hz; Capacitive load
Capacitive load for each channelO1 O4; 47 渭 F
Supply voltage (system)5 VDC; via data contacts
Current consumption (5 V system supply)120mA
ParameterValue
Supply voltage (field)24 VDC, SELV/PELV (-25 +20 %); via power jumper contacts (power supply via blade contact; transmission (field side supply voltage only) via spring contact)
Current consumption, field supply (module with no external load)35mA
Number of incoming power jumper contacts2
Number of outgoing power jumper contacts2
Current carrying capacity (power jumper contacts)10A
Achievable safety classesSIL 3; Category 4, PLe (two-channel); SIL 2; Category 2; PLd (one-channel)
Safety standardsIEC 61508-1 -7; EN ISO 13849-1; EN 62061
Interface types according to ZVEI (inputs)Drain; A, C0, C1, C2, C3
Interface types according to ZVEI (outputs)Source; C0, C1, C2, C3, D0, D1, D2, D3
Test pulse duration (max.)500ms
Test pulse duration (min.)0ms
Connection technology: inputs / outputs16 x CAGE CLAMP®
Connection type 1Inputs/outputs
Solid conductor0.08 2.5 mm2 / 28 14 AWG
Fine-stranded conductor0.08 2.5 mm2 / 28 14 AWG
Strip length8 9 mm / 0.31 0.35 inches
Width24 mm / 0.945 inches
Height100 mm / 3.937 inches
Depth67.8 mm / 2.669 inches
Depth from upper-edge of DIN-rail60.6 mm / 2.386 inches
Mounting typeDIN-35 rail
ETIM 9.0EC001599
ETIM 8.0EC001599
ECCNNO US CLASSIFICATION

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.