WAGO 750-672 Stepper Controller; 70 VDC; 7.5 A

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the WAGO 750-672?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 750-672 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
750-672
Material Number
—
Manufacturer
WAGO
Product ID
46947

Get a Free Quote

Request pricing and availability for 750-672.

More parts to source? Send your whole list in one enquiry

Key specifications

Output current per channel
0.5A
Switching frequency (max.)
5 Hz;?Inductive load per IEC 947-5-1, DC 13
Output voltage
Control voltage: 24 VDC (-25 % +30 %); Closed current: 120 mA + 2 x 0.5 A (DO1, DO2, load-dependent);Motor voltage: 55 VDC nominal value; Absolute upper limit: 71.5 V; Absolute lower limit: 18 V; Closed current (typ.) = 5 mA; Protection via external fuse 5 A
Protection
Short circuit monitoring of motor connections:Winding short circuit and short circuit to 0 V and 24 V24 V supply:Reverse voltage protectionMotor supply:Reverse voltage protection via external fuse
Supply voltage (system)
5 VDC; Via data contacts
Weight
175g
See all specifications

Product Highlights

  1. Preset I/O: DI 1 drive stop, DI 2 reference input, DI 3 jog positive, DI 4 jog negative, DI 5 limit switch positive, DI 6 limit switch negative, DO 1 target reached, DO 2 error, all freely reconfigurable
  2. Motor output: 2 x 5.0 A continuous with 2 x 7.5 A transient, 55 VDC nominal motor voltage with absolute limits of 18 V and 71.5 V
  3. Digital outputs: 2 short-circuit-protected channels rated 0.5 A each, maximum switching frequency 5 Hz, suitable for resistive loads, inductive loads up to 2 H, and lamps
  4. Control and logic: 24 VDC control voltage (-25 % +30 %), input filter 100 µs with software filter option, 2.8 mA typical input current, signal ranges -3 to +5 VDC for 0 and 15 to 30 VDC for 1
  5. Stepper performance: 64 microsteps per full step, 15 bits plus 16-bit prescaler resolution, 23 bits plus sign bit stepper resolution, maximum full-step frequency 7,812 Hz
  6. Diagnostics: overcurrent, short circuit or ground fault, overtemperature, supply voltage monitoring, and motor wire break, with short-circuit monitoring of motor connections and reverse voltage protection on 24 V and motor supply
  7. Connection and mounting: 24 CAGE CLAMP connections for 0.08 to 1.5 mm² (28 to 14 AWG) with 5 to 6 mm strip length, DIN-35 rail mounting, 48 mm width, IP20 protection
750-672

Product Information

Technical Specifications

Specifications for 750-672

ParameterValue
Device-specificInputs (preset): DI 1: Drive stop, DI 2: Reference input, DI 3: Jog switch in positive direction, DI 4: Jog switch in negative direction, DI 5: Limit switch in positive direction, DI 6: Limit switch in negative direction, Outputs (preset): DO 1: Target reached, DO 2: Error, Inputs and outputs can be freely reconfigured.
Number of digital outputs2
Input filter100 渭s, software filter can be connected
Input current (typ.)2.8 mA
Output current per channel0.5A
Output currentshort-circuit-protected
Switching frequency (max.)5 Hz;?Inductive load per IEC 947-5-1, DC 13
Load typeResistive load, inductive load (max. 2?H), lamps
Output current (max.) (motor)2 x 5.0 A (2 x 7.5 A transient)
Output voltageControl voltage: 24 VDC (-25 % +30 %); Closed current: 120 mA + 2 x 0.5 A (DO1, DO2, load-dependent);Motor voltage: 55 VDC nominal value; Absolute upper limit: 71.5 V; Absolute lower limit: 18 V; Closed current (typ.) = 5 mA; Protection via external fuse 5 A
Voltage range for signal (0)-3 +5 VDC
Voltage range for signal (1)15 30 VDC
DiagnosticsOvercurrent, short circuit or ground fault, overtemperature, supply voltage monitoring, motor wire break
Resolution15 bits + 16 bit prescaler; 64 microsteps per full step
Stepper resolution23 bits + sign bit
Stepper frequency (full-step) max.7,812Hz
Data width12-byte input/output
ProtectionShort circuit monitoring of motor connections:Winding short circuit and short circuit to 0 V and 24 V24 V supply:Reverse voltage protectionMotor supply:Reverse voltage protection via external fuse
FunctionsPositioning, sin2-shaped ramps, setpoint change on the fly, rotational speed control
Supply voltage (system)5 VDC; Via data contacts
Current consumption (5 V system supply)70mA
Isolation500 V system/field
IndicatorsLED (A) red: Error; LED (B, C) yellow: Operation, Run Program Active; LED (D, E, F) green: Enable, Control Voltage, Motor Voltage
Connection technology: inputs / outputs24 x CAGE CLAMP®
Connection type 1Inputs/Outputs
Solid conductor0.08 1.5 m㎡/ 28 14 AWG
Fine-stranded conductor0.08 1.5 m㎡/ 28 14 AWG
ParameterValue
Strip length5 6 mm / 0.2 0.24 inches
Connection requirement (permissible cable length)30m
Connection requirement (permissible cable type)Motor connection: shielded
Note (conductor cross-section)14 AWG: THHN, THWN
Width48 mm / 1.89 inches
Height100 mm / 3.937 inches
Depth69.8 mm / 2.748 inches
Depth from upper-edge of DIN-rail62.6 mm / 2.465 inches
Mounting typeDIN-35 rail
Colorlight gray
Housing materialPolycarbonate; polyamide 6.6
Fire load2.439MJ
Weight175g
Conformity markingCE
Ambient temperature (operation)0 … +55 °C
Ambient temperature (storage)-40 … 85 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitude0 2000 m / 0 6562 ft
Mounting positionHorizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Relative humidity (without condensation)95%
Vibration resistanceper IEC 60068-2-6
Shock resistance15g per IEC 60068-2-27
EMC immunity to interferenceper EN 61000-6-2
EMC emission of interferenceper EN 61000-6-3
Exposure to pollutantsPer IEC 60068-2-42 and IEC 60068-2-43
Permissible pollutant concentration H2S at a relative humidity < 75%10ppm
Permissible pollutant concentration SO 2 at a relative humidity < 75%25ppm
Product Group15 (I/O System)
eCl@ss 10.027-24-26-05
eCl@ss 9.027-24-26-05
ETIM 9.0EC001601
ETIM 8.0EC001601
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typebox
Country of originDE
GTIN4045454763701
Customs tariff number8537109160
RoHS Compliance StatusCompliant,No Exemption

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.