- 750-8101/025-000
WAGO 750-8101/025-000 is a controller for the WAGO-I/O-SYSTEM with a Cortex A8 CPU at 600 MHz and real-time Linux 3.18 with PREEMPT_RT patch. It provides two RJ-45 Ethernet ports supporting Modbus TCP and UDP, plus DHCP, with 10/100 Mbit/s transmission over twisted-pair S-UTP Cat. 5 cable up to 100 m. Programming uses e!COCKPIT based on CODESYS V3; Instruction List (IL) per IEC 61131-3 is supported. Memory includes 256 MB RAM, 256 MB flash, and 12 mB program/data memory. System supply is 24 VDC (-25 +30 %) via CAGE CLAMP; field supply is 24 VDC (-25 +30 %) via power jumper contacts rated 10 A. Dimensions are 61.5 mm width, 100 mm height, 71.9 mm depth; weight 159 g; IP20; operating temperature -20 to +60 °C.
- 750-8110
WAGO 750-8110 controller, category Controllers Bus Couplers I/O. Second-generation PFC100 with two RJ-45 Ethernet ports. Cortex A8 CPU at 600 MHz running real-time Linux with PREEMPT_RT patch. Programming via CODESYS V3.5; configuration via CODESYS V3; IEC 61131-3 Instruction List (IL). Communications: Modbus TCP master/slave; Ethernet protocols include DHCP; Web-Visu visualization. Ethernet transmission rate 10/100 Mbit/s over twisted-pair S-UTP, 100 Ω, Cat. 5, maximum cable length 100 m. Memory: 512 MB RAM, 4096 MB flash, 128 Kbytes non-volatile hardware memory, 32 MB program memory, 128 MB data memory. Supply voltage 24 VDC (-25 +30 %) via pluggable connector; typical input current 300 mA at nominal load; total system supply current 700 mA. 500 V system/field isolation. DIN-35 rail mounting. Dimensions 49.5 x 96.8 x 71.9 mm; weight 111.9 g. Operating ambient temperature 0 to +55 °C; storage -25 to +85 °C; IP20; CE marking.
- 750-8111
WAGO 750-8111 PFC100 controller for the modular WAGO I/O System. It provides two ETHERNET interfaces with an integrated switch for line topology, 10/100 Mbit/s transmission over twisted-pair S-UTP Cat. 5 cable to 100 m maximum, and Modbus TCP master/slave communication via 2 x RJ-45. The Cortex A8 CPU runs at 600 MHz with real-time Linux (PREEMPT_RT patch). Programming uses CODESYS V3.5 per IEC 61131-3, with Instruction List (IL) supported. Memory includes 512 MB RAM, 4096 MB flash, 128 Kbytes non-volatile hardware memory, and 32 MB program memory. System supply is 24 VDC (-25 +30 %) via pluggable CAGE CLAMP connection; field supply is 24 VDC (-25 +30 %) via power jumper contacts. Operating ambient temperature is 0 to +55 °C; protection type IP20.
- 750-8112
WAGO 750-8112 controller with a 600 MHz Cortex A8 CPU running real-time Linux with the PREEMPT_RT patch. Programming and configuration use CODESYS V3.5; Instruction List (IL) is supported per IEC 61131-3. Communication includes Modbus TCP master/slave, DHCP, and Web-Visu visualization. ETHERNET runs at 10/100 Mbit/s over twisted-pair S-UTP, 100 Ω, Cat. 5 cable, maximum 100 m. Memory: 512 MB RAM, 4096 MB flash, 128 Kbytes non-volatile hardware memory, 32 MB program memory, 128 MB data memory. System supply is 24 VDC (-25 +30 %) via pluggable CAGE CLAMP connection; field supply is 24 VDC (-25 +30 %) via power jumper contacts rated 10 A. Dimensions 61.5 x 100 x 71.9 mm, 166 g, IP20, 0 to +55 °C operation.
- 750-812
WAGO 750-812 is a Modbus RTU controller and bus coupler for the WAGO I/O System. It supports up to 99 fieldbus nodes, 64 modules per node, and 6,000 I/O points. Programming uses Instruction List (IL) per IEC 61131-3 in WAGO-I/O-PROV2.3 (based on CODESYS V2.3), with 32 KB program and 32 KB data memory. Cycle time is under 3 ms for 1000 bit instructions/256 digital I/O. The Modbus RTU interface uses a 9-pin D-sub socket; transmission rates are 150/19.2 kBd, maximum bus segment length 1200 m, over shielded Cu cable 2 (4) x 0.25 mm2. System supply is 24 VDC (-25 +30 %) via CAGE CLAMP; field supply is 24 VDC (-25 +30 %) via power jumper contacts rated 10 A. Dimensions are 50.5 x 71.1 x 100 mm; weight 189 g; IP20; operating temperature 0 to +55 °C.
- 750-815/300-000
WAGO 750-815/300-000 is a Modbus RTU controller in the I/O System product group, with a 16-bit CPU and no visualization. It supports Instruction List (IL) per IEC 61131-3, programmed via WAGO-I/O-PROV2.3 (based on CODESYS V2.3), and configured with WAGO-I/O-CHECK. Transmission rates are 150/115.2 kBd over shielded Cu cable 2 (4) x 0.25 mm2, with a maximum bus segment length of 1200 m and up to 247 fieldbus nodes on the master. The controller provides 6,000 I/O points, 32 KB program memory, 32 KB data memory, and 8 Kbytes non-volatile software memory. Cycle time is less than 3 ms for 1000 bit instructions/256 digital I/O. It measures 50.5 mm wide, 100 mm high, and 71.1 mm deep, weighs 189 g, and operates from 0 to +55 °C at IP20.
- 750-815/325-000
WAGO 750-815/325-000 is a DIN-rail controller and bus coupler for the I/O system, with Modbus RTU communication via one D-sub 9 socket. It uses a 16-bit CPU, supports Instruction List (IL) per IEC 61131-3, and is programmed in WAGO-I/O-PROV2.3 (based on CODESYS V2.3); configuration is via WAGO-I/O-CHECK. Cycle time is under 3 ms for 1000 bit instructions/256 digital I/O. Transmission rate is 150/115.2 kBd, maximum bus segment length is 1200 m, and up to 247 fieldbus nodes are supported on the master. Memory includes 32 KB program, 32 KB data, and 8 Kbytes non-volatile software memory. Supply voltage is 24 VDC (-25 +30 %) via pluggable CAGE CLAMP connection. Dimensions are 50.5 mm wide, 100 mm high, and 71.1 mm deep; weight is 187.9 g. Operating ambient temperature is -20 to +60 °C, protection type IP20.
- 750-816/300-000
WAGO 750-816/300-000 is a Modbus RTU controller with an RS-232 interface. It uses a 16-bit CPU and supports programming in Instruction List (IL) per IEC 61131-3 within WAGO-I/O-PROV2.3, based on CODESYS V2.3; configuration is via WAGO-I/O-CHECK. Transmission rates are 150/115.2 kBd over shielded Cu cable 2 (4) x 0.25 mm2, with a maximum bus segment length of 1200 m and up to 247 fieldbus nodes on the master. Cycle time is under 3 ms for 1000 bit instructions/256 digital I/O. The controller provides 6,000 I/O points, 32 KB program memory, 32 KB data memory, 8 Kbytes non-volatile software memory, and a fieldbus process image of up to 1024 bytes/1024 bytes. Up to 64 modules are supported per node.