Product Model
750-812
Material Number
—
Manufacturer
WAGO
Product ID
45077

Get a Free Quote

Request pricing and availability for 750-812.

More parts to source? Send your whole list in one enquiry

Key specifications

Communications
Modbus RTU
Supply voltage (system)
24 VDC (-25 +30 %); Via pluggable connector (CAGE CLAMP®connection)
Supply voltage (field)
24 VDC (-25 +30 %); Via power jumper contacts
Weight
189g
Ambient temperature (operation)
0 … +55 °C
Protection type
IP20
See all specifications

Product Highlights

  1. Fieldbus and PLC: Modbus RTU fieldbus coupler with PLC functionality, programmed via WAGO-I/O-PROV2.3 (CODESYS V2.3) using Instruction List (IL) per IEC 61131-3
  2. Performance: Cycle time under 3 ms for 1000 bit instructions or 256 digital I/O, with 32 KB program memory and 32 KB data memory
  3. Modbus RTU Interface: Transmission rate 150/19.2 kBd over shielded Cu cable 2 (4) x 0.25 mm2, maximum bus segment length 1200 m, up to 99 fieldbus nodes on master
  4. I/O Capacity: Up to 6,000 I/O points, 64 modules per node, and 1024 bytes/1024 bytes input/output process image
  5. Supply and Isolation: 24 VDC (-25 to +30 %) system and field supply via CAGE CLAMP connections, 500 V system/supply isolation, 10 A power jumper contact current carrying capacity
  6. Housing and Mounting: Polycarbonate and polyamide 6.6 housing, IP20, light gray, 50.5 x 71.1 x 100 mm, DIN-35 rail mounting, 0 to +55 °C operating temperature
750-812

Product Information

Technical Specifications

Specifications for 750-812

ParameterValue
CommunicationsModbus RTU
Visualizationnone
Programming languages per IEC 61131-3Instruction List (IL)
Programming environmentWAGO-I/O-PROV2.3 (based on CODESYS V2.3)
Cycle time< 3 ms for 1000 bit instructions/ 256 digital I/O
Transmission rate150/19.2 kBd
Bus segment length (max.)1200 m
Transmission medium (communication/fieldbus)Shielded Cu cable 2 (4) x 0.25 mm2
Number of fieldbus nodes on master (max.)99
Number of I/O points6,000
Program memory32 KB
Data memory32 KB
Non-volatile software memory8Kbytes
Memory for fieldbus input variables (max.)512Byte
Memory for fieldbus output variables (max.)512Byte
Number of modules per node (max.)64
Input and output process image (fieldbus) max.1024 bytes/1024 bytes
Supply voltage (system)24 VDC (-25 +30 %); Via pluggable connector (CAGE CLAMP®connection)
Input current (typ.) at nominal load (24 V)500mA
Power supply efficiency (typ.) at nominal load (24 V)87%
Current consumption (5 V system supply)350mA
Total current (system supply)1,650mA
Supply voltage (field)24 VDC (-25 +30 %); Via power jumper contacts
Current carrying capacity (power jumper contacts)10A
Number of outgoing power jumper contacts3
Isolation500 V system/supply
Connection technology: communication/fieldbusModbus RTU: 1 x D-sub 9 socket
Connection technology: system supply2 x CAGE CLAMP®
Connection technology: field supply6 x CAGE CLAMP®
Connection type 1System/field supply
Solid conductor0.08 … 2.5 mm2 / 28 14 AWG
Fine-stranded conductor0.08 … 2.5 mm2 / 28 14 AWG
Strip length8 9 mm / 0.31 0.35 inches
Connection technology: device configuration1 x Male connector; 4-pole
Width50.5 mm / 1.988 inches
Height71.1 mm / 2.799 inches
Depth100 mm / 3.937 inches
Weight189g
Colorlight gray
Housing materialPolycarbonate; polyamide 6.6
Conformity markingCE
Ambient temperature (operation)0 … +55 °C
Ambient temperature (storage)-25 … +85 °C
Protection typeIP20
ParameterValue
Pollution degree2 per IEC 61131-2
Operating altitudewithout temperature derating: 0 2000 m; with temperature derating: 2000 5000 m (0.5 K/100 m); 5000 m (max.)
Relative humidity (without condensation)95%
Mounting positionHorizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Mounting typeDIN-35 rail
Vibration resistanceper IEC 60068-2-6
Shock resistance15g per IEC 60068-2-27
EMC immunity to interferenceper EN 61000-6-2, marine applications
EMC emission of interferenceper EN 61000-6-4, marine applications
Exposure to pollutantsPer IEC 60068-2-42 and IEC 60068-2-43
Fire load4.974MJ
Permissible pollutant concentration H2S at a relative humidity &#60; 75%10ppm
Permissible pollutant concentration SO 2 at a relative humidity &#60; 75%25ppm
Product Group15 (I/O System)
eCl@ss 10.027-24-26-07
eCl@ss 9.027-24-26-07
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typebox
Country of originDE
GTIN4045454654610
Customs tariff number8537109160
End of Sale2018-05-31
End of Production2018-06-05
End of Delivery2018-06-15
End of Service and Repair2020-05-30
CAS-No.12060-00-3
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)e7038aa9-8cc0-4da6-8909-85518bc5eac6
SCIP notification number (Belgium)657dd586-c3d4-4cc0-8b54-cdac8deae548
SCIP notification number (Bulgaria)fc9de607-ccf6-4498-ac5f-66ca80514590
SCIP notification number (Czech Republic)59385d98-b59c-4011-b55b-0378b912e49a
SCIP notification number (Denmark)174d6f6a-ca43-4144-b1c8-67fe00afab3a
SCIP notification number (Finland)c0f5dd80-edc2-460b-9bee-b6072eb267eb
SCIP notification number (France)c473437e-4f86-4f3c-a8da-104b942f53df
SCIP notification number (Germany)939c7fe9-c8ce-4ee0-b7b1-73c9f70940fc
SCIP notification number (Hungary)7e48724c-312c-4452-83c5-0254afc0e6ac
SCIP notification number (Italy)55784ed2-6fb6-46a3-b5d5-9903c2f445ec
SCIP notification number (Netherlands)876f098b-81b2-4f69-ad42-baec9da69105
SCIP notification number (Poland)40542fc1-9697-47f1-9a0f-bf333f618707
SCIP notification number (Romania)490305e3-aa19-43db-9e07-afd538127e6b
SCIP notification number (Sweden)14e66ab7-63df-4a9e-9349-87b81a251f21

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp