Industrial Automation Parts. Prompt replies from real people.

WAGO 750-666/000-004 Controllers Bus Couplers I/O

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the WAGO 750-666/000-004?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 750-666/000-004 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
750-666/000-004
Material Number
—
Manufacturer
WAGO
Product ID
45340

Get a Free Quote

Request pricing and availability for 750-666/000-004.

More parts to source? Send your whole list in one enquiry

Key specifications

Protocols
PROFIsafe V2.6 (PROFINET) and V2.4 (PROFIBUS, PROFINET)
Signal type (voltage)
24 VDC
Signal frequency (max.)
50Hz
Output current per channel
10A
Supply voltage (system)
5 VDC; via data contacts
Number of incoming power jumper contacts
2
See all specifications

Product Highlights

  1. Safety Ratings: SIL 3, Category 4, PLe in two-channel configuration and SIL 2, Category 2, PLd in one-channel configuration per IEC 61508-1 to -7, EN ISO 13849-1, and EN 62061
  2. Digital I/O: 4 fail-safe digital inputs with test pulse and 2 fail-safe power outputs with test pulse, 24 VDC, Type 1 input characteristic per IEC 61131, 3 mA typical input current per channel at signal 1, maximum 50 Hz signal frequency
  3. Output Current: 10 A per channel for general applications, 2 A per channel for Pilot Duty/DC13, 20 A per module, derated to 10 A per channel at 40 °C and 6 A per channel at 55 °C
  4. PROFIsafe: V2.6 for PROFINET and V2.4 for PROFIBUS and PROFINET, address adjustable via DIP switch or engineering software
  5. Indicators: LEDs A-D green/red for status/error of inputs I1-I4, LEDs I-K green/red for status/error of outputs O1-O2, LED E red for group error, LEDs F-H green/red for diagnostics
  6. Connections and Mounting: 16 x CAGE CLAMP connections for 0.08 to 2.5 mm2 / 28 to 14 AWG conductors with 8 to 9 mm strip length, fixed pluggable connector, DIN-35 rail mounting, 24 mm width
750-666/000-004

Product Information

Technical Specifications

Specifications for 750-666/000-004

ParameterValue
ProtocolsPROFIsafe V2.6 (PROFINET) and V2.4 (PROFIBUS, PROFINET)
Configuration optionsPROFIsafe address adjustable via DIP switch or engineering software
IndicatorsLED (A-D) green/red: Status/Error I1 I4; LED (I-K) green/red: Status/error O1 O2; LED (E) red: Group error; LED (F-H) green/red: Diagnostics
Number of Channels6
Pluggable connectorfixed
Number of digital inputs4
Signal typeDigital
Signal type (voltage)24 VDC
Sensor connection4 x (Fail-safe input with test pulse)
Input characteristicType 1 per IEC 61131
Input current per channel for signal (1) typ.3mA
Signal frequency (max.)50Hz
Output current per channel10A
Number of digital outputs2
Output currentper channel: O1 O2: 2 A (鈥淧ilot Duty/ DC13); 10 A other applications; Derating output current per channel: 10 A at 40 °C; 6 A at 55 °C (see manual for details)
Output current (module)20A
Actuator connection2 x (fail-safe output with test pulse)
Output circuit designPower outputs
Switching frequency (max.)50 Hz; Resistive load
Switching frequency (max.) (2)0.1 Hz; Inductive load
Switching frequency (max.) (3)0.1 Hz; Capacitive load
Supply voltage (system)5 VDC; via data contacts
Current consumption (5 V system supply)120mA
ParameterValue
Supply voltage (field)24 VDC, SELV/PELV (-25 +30 %); for digital inputs; Power outputs: SELV/PELV 24 VDC (-25 +20 %) for inductive loads (鈥淧ilot Duty/ DC13); SELV/PELV 24 VDC (-25 +30 %) other applications; Current consumption from power outputs: 3 mA + load current
Current consumption, field supply (module with no external load)30mA
Number of incoming power jumper contacts2
Number of outgoing power jumper contacts2
Current carrying capacity (power jumper contacts)10A
Achievable safety classesSIL 3; Category 4, PLe (two-channel); SIL 2; Category 2; PLd (one-channel)
Safety standardsIEC 61508-1 -7; EN ISO 13849-1; EN 62061
Interface types according to ZVEI (inputs)Drain; A, C0, C1, C2, C3
Interface types according to ZVEI (outputs)Source; C0, C1, C2, C3, D0, D1, D2, D3
Test pulse duration (max.)500ms
Test pulse duration (min.)0ms
Connection technology: inputs / outputs16 x CAGE CLAMP®
Connection type 1Inputs/outputs
Solid conductor0.08 2.5 mm2 / 28 14 AWG
Fine-stranded conductor0.08 2.5 mm2 / 28 14 AWG
Strip length8 9 mm / 0.31 0.35 inches
Width24 mm / 0.945 inches
Height100 mm / 3.937 inches
Depth67.8 mm / 2.669 inches
Depth from upper-edge of DIN-rail60.6 mm / 2.386 inches
Mounting typeDIN-35 rail
ETIM 9.0EC001599
ETIM 8.0EC001599
ECCNNO US CLASSIFICATION

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp