Industrial Automation Parts. Prompt replies from real people.

WAGO 750-8211/040-001 Controllers Bus Couplers I/O

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the WAGO 750-8211/040-001?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 750-8211/040-001 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
750-8211/040-001
Material Number
—
Manufacturer
WAGO
Product ID
46343

Get a Free Quote

Request pricing and availability for 750-8211/040-001.

More parts to source? Send your whole list in one enquiry

Key specifications

Communications
Modbus TCP master/slave
Supply voltage (system)
24 VDC; Via pluggable connector (CAGE CLAMP® connection); Derating must be observed!
Supply voltage (field)
24 VDC;?Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power jumper contacts; Derating must be observed!
Weight
333.6g
Ambient temperature (operation)
-40 … +70 °C
Protection type
IP20
See all specifications

Product Highlights

  1. Communications: Modbus TCP master/slave, DHCP, and IEC 60870 telecontrol protocols
  2. Controller: Cortex A8 CPU at 1 GHz with real-time Linux (PREEMPT_RT) and CODESYS V3.5 programming per IEC 61131-3
  3. Interfaces: 2 x RJ-45 for Modbus TCP/UDP and 2 x SFP slots for fiber-optic connections
  4. Memory: 512 MB RAM, 4096 MB internal flash, and SD card slot with push-push mechanism and sealable cover lid
  5. Operating Conditions: -40 to +70 °C ambient temperature, IP20 protection, and 24 VDC system and field supply
  6. Approvals: CE conformity marking and UL approval for industrial use
750-8211/040-001

Product Information

Technical Specifications

Specifications for 750-8211/040-001

ParameterValue
CommunicationsModbus TCP master/slave
ETHERNET protocolsDHCP
Telecontrol protocolsIEC 60870
VisualizationWeb-Visu
Operating systemReal-time Linux (with PREEMPT_RT patch)
CPUCortex A8; 1 GHz
Programming languages per IEC 61131-3Instruction List (IL)
Programming environmentCODESYS V3.5, Firmware Release 23 or higher
Configuration optionsCODESYS V3
Transmission rateETHERNET: 10/100 Mbit/s; Fiber optic: 100 Mbit/s
Transmission medium (communication/fieldbus)ETHERNET: Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length;
Main memory (RAM)512MB
Internal memory (flash)4096MB
Non-volatile hardware memory128Kbytes
Program memoryCODESYS V2: 16 mB; CODESYS V3: 32 mB
Data memoryCODESYS V2: 64 mB; CODESYS V3: 128 mB
Non-volatile software memory128.Kbytes
Type of memory cardSD card
Memory card slotPush-push mechanism; cover lid (sealable)
Number of modules per node (max.)64
Number of modules without a bus extension (max.)64
Input and output process image (internal) max.1000 Words/ 1000 Words
Input and output process image (Modbus®) max.CODESYS V2: 1000 Words/1000 Words; CODESYS V3: 32000 Words/32000 Words
IndicatorsLED (SYS, RUN, I/O, U1 U7) red/green/orange: Status of system, program, local data bus, status programmable by user (can be used via CODESYS library); LED (A, C) green: Status of system power supply, field supply
DeratingDerating (supply voltage):Ambient temperatures under laboratory conditions: (?25 +30°%);for ?40 +55掳°C: 24掳V (?25 +20°%);for +55 +70°°C: 24掳V (?25 +10°%);Lower limit in all temperature ranges: ?27.5°% (including 15°% residual ripple)
Supply voltage (system)24 VDC; Via pluggable connector (CAGE CLAMP® connection); Derating must be observed!
Input current (typ.) at nominal load (24 V)550mA
Total current (system supply)1,700mA
Supply voltage (field)24 VDC;?Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power jumper contacts; Derating must be observed!
Current carrying capacity (power jumper contacts)10A
Number of outgoing power jumper contacts2
Rated surge voltage1 kV
Connection technology: communication/fieldbusModbus (TCP, UDP): 2 x RJ-45;?2 x SFP slots (e.g., with SFP module and LC fiber-optic connector)
Connection technology: system supply2 x CAGE CLAMP®
Connection technology: field supply4 x CAGE CLAMP®
Connection type 1System/field supply
Solid conductor0.25 2.5 m㎡/ 24 14 AWG
Fine-stranded conductor0.25 2.5 m㎡/ 24 14 AWG
Strip length8 9 mm / 0.31 0.35 inches
Connection technology: device configuration1 x Male connector; 4-pole
Width78.6 mm / 3.094 inches
Height100 mm / 3.937 inches
Depth71.9 mm / 2.831 inches
Depth from upper-edge of DIN-rail64.7 mm / 2.547 inches
Weight333.6g
Housing materialPolycarbonate; polyamide 6.6
ParameterValue
Conformity markingCE
Ambient temperature (operation)-40 … +70 °C
Ambient temperature (storage)-40 … 85 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitudewithout temperature derating: 0 2000 m; with temperature derating: 2000 5000 m (0.5 K/100 m); 5000 m (max.)
Relative humidity (without condensation)95%
Relative humidity (with condensation)Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
Mounting positionHorizontal left, horizontal up, vertical top and vertical bottom
Mounting typeDIN-35 rail
Vibration resistanceper IEC 60068-2-6 (acceleration: 0.7g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373
Shock resistanceper IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373
EMC immunity to interferenceper EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26;EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994
EMC emission of interferenceper EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
Exposure to pollutantsper IEC 60068-2-42 and IEC 60068-2-43
Fire load2.513MJ
Permissible pollutant concentration H2S at a relative humidity < 75%10ppm
Permissible pollutant concentration SO 2 at a relative humidity < 75%25ppm
ETIM 9.0EC000236
ETIM 8.0EC000236
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typebox
Country of originDE
GTIN4066966100914
Customs tariff number8537109160
CAS-No.1303-86-2
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)796c4755-958a-48e5-95af-623c2e19b578
SCIP notification number (Belgium)0c7dd553-eade-442f-92c9-17ecebd942de
SCIP notification number (Bulgaria)3ea3086b-7b8c-4d93-84db-bdd7abb51310
SCIP notification number (Czech Republic)f41bb1de-84e8-442d-a839-0ea511d3705c
SCIP notification number (Denmark)23e75201-db2b-4c51-b7d6-56670a3de190
SCIP notification number (Finland)8a0b24de-7e51-472b-aafa-10b8b3ee0807
SCIP notification number (France)0b21716b-41cc-443e-920e-5e2651a1f01d
SCIP notification number (Germany)55468596-14be-40ad-a4d0-a27dbadef80e
SCIP notification number (Hungary)39aa050c-dd9c-4547-8451-e99729ed34a8
SCIP notification number (Italy)c96ce986-6965-4136-860f-7e59ed6df150
SCIP notification number (Netherlands)51bdbc69-9fc8-42d8-a00f-f55559af0e27
SCIP notification number (Poland)f27e7503-d3dc-447a-8a7c-735232644e54
SCIP notification number (Romania)5bae77ae-0f84-4223-b6ec-ffb39b529cdf
SCIP notification number (Sweden)2e661474-c880-43fd-9354-b4f2748f6fa9

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
Controller PFC200 (750-8211/040-001) | WAGO USA