Industrial Automation Parts. Prompt replies from real people.

WAGO 750-8216/025-001 Controller PFC200

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/27/2026

Q1Can you supply the WAGO 750-8216/025-001?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 750-8216/025-001 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
750-8216/025-001
Material Number
—
Manufacturer
WAGO
Product ID
41667

Get a Free Quote

Request pricing and availability for 750-8216/025-001.

More parts to source? Send your whole list in one enquiry

Key specifications

Communications
PROFIBUS
Supply voltage (system)
24 VDC (-25 +30 %); Via pluggable connector (CAGE CLAMP®connection)
Supply voltage (field)
24 VDC (-25 +30 %); Via power jumper contacts
Weight
270.8g
Ambient temperature (operation)
-20 … +60 °C
Protection type
IP20
See all specifications

Product Highlights

  1. Fieldbus and ETHERNET Communication: PROFIBUS via 1 x D-sub 9 socket, CANopen via 1 x D-sub 9 plug, and Modbus TCP/UDP via 2 x RJ-45, with ETHERNET transmission at 10/100 Mbit/s over twisted pair S-UTP, 100 Ω, Cat. 5 cable up to 100 m
  2. Serial and Telecontrol Interfaces: RS-232 and RS-485 via D-sub 9 sockets, plus IEC 60870-5-101/-103, IEC 60870-5-104, IEC 61850, and DNP3 telecontrol protocols
  3. Controller and Programming: Cortex A8 1 GHz CPU with real-time Linux including PREEMPT_RT patch, 512 MB RAM, 4096 MB flash, 16 MB program memory, and 64 MB data memory, programmed via CODESYS V3.5 firmware release 23 or higher using IEC 61131-3 Instruction List
  4. I/O Capacity: Up to 250 modules per node, 64 modules without bus extension, and process image sizes up to 1000 words/1000 words internal, 32000 words/32000 words for CODESYS V3 Modbus, 244 bytes/244 bytes for PROFIBUS, and 2000 words/2000 words for CAN
  5. Power and Wiring: 24 VDC (-25 +30 %) system and field supply via CAGE CLAMP® connectors, 550 mA typical input current at nominal load, 1700 mA total system supply current, 10 A power jumper contact capacity, and 500 V system/field isolation
  6. Environmental and Mechanical: IP20 protection, -20 to +60 °C operating temperature, 95 % relative humidity without condensation, 4g vibration resistance per IEC 60068-2-6, 15g shock resistance per IEC 60068-2-27, and DIN-35 rail mounting in horizontal or vertical positions
750-8216/025-001

Product Information

Technical Specifications

Specifications for 750-8216/025-001

ParameterValue
CommunicationsPROFIBUS
ETHERNET protocolsDHCP
Telecontrol protocolsIEC 60870
VisualizationWeb-Visu
Operating systemReal-time Linux (with PREEMPT_RT patch)
CPUCortex A8; 1 GHz
Programming languages per IEC 61131-3Instruction List (IL)
Programming environmentCODESYS V3.5, Firmware Release 23 or higher
Configuration optionsCODESYS V3
Transmission rateETHERNET: 10/100 mbit/s
Transmission medium (communication/fieldbus)ETHERNET: Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length
Main memory (RAM)512MB
Internal memory (flash)4096MB
Non-volatile hardware memory128Kbytes
Program memory16 mB
Data memory64 mB
Non-volatile software memory128Kbytes
Type of memory cardSD card
Memory card slotPush-push mechanism; Cover lid (sealable)
Number of modules per node (max.)250
Number of modules without a bus extension (max.)64
Input and output process image (internal) max.1000 Words/1000 Words
Input and output process image (Modbus®) max.CODESYS V2: 1000 Words/1000 Words; CODESYS V3: 32000 Words/32000 Words
Input and output process image (PROFIBUS) max.244 bytes/244 bytes
Input and output process image (CAN) max.2000 Words/2000 Words
IndicatorsLED (SYS, RUN, I/O, CAN, BF, DIA, U1 U4) red/green/orange: Status system, program, internal data bus, CANopen, PROFIBUS, PROFIBUS diagnostics, status programmable by user (can be used via CODESYS library); LED (A, B) green: System power supply status, field supply
Supply voltage (system)24 VDC (-25 +30 %); Via pluggable connector (CAGE CLAMP®connection)
Input current (typ.) at nominal load (24 V)550mA
Total current (system supply)1,700mA
Supply voltage (field)24 VDC (-25 +30 %); Via power jumper contacts
Current carrying capacity (power jumper contacts)10A
Number of outgoing power jumper contacts3
Isolation500 V system/field
Connection technology: communication/fieldbusPROFIBUS: 1 x D-sub 9 socket; CANopen: 1 x D-sub 9 plug; modbus (TCP, UDP): 2 x RJ-45; modbus RTU: 1 x D-sub 9 socket; RS-232 serial interface: 1 x D-sub 9 socket; RS-4852 interface: 1 x D-sub 9 socket;?Telecontrol protocol IEC 60870-5-101/-103: 1 x D-sub 9 socket;?Telecontrol protocol IEC 60870-5-104:?1 x RJ-45;?Telecontrol protocol IEC 61850:?1 x RJ-45;?Telecontrol protocol DNP3:?1 x RJ-45 or D-sub 9 socket
Connection technology: system supply2 x CAGE CLAMP®
Connection technology: field supply6 x CAGE CLAMP®
Connection type 1System/field supply
Solid conductor0.08 … 2.5 mm2 / 28 14 AWG
Fine-stranded conductor0.08 … 2.5 mm2 / 28 14 AWG
Strip length8 9 mm / 0.31 0.35 inches
Connection technology: device configuration1 x Male connector; 4-pole
Width112 mm / 4.409 inches
Height100 mm / 3.937 inches
Depth71.9 mm / 2.831 inches
Depth from upper-edge of DIN-rail64.7 mm / 2.547 inches
ParameterValue
Weight270.8g
Housing materialPolycarbonate; polyamide 6.6
Conformity markingCE
Ambient temperature (operation)-20 … +60 °C
Ambient temperature (storage)-40 … 85 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitudewithout temperature derating: 0 2000 m; with temperature derating: 2000 5000 m (0.5 K/100 m); 5000 m (max.)
Relative humidity (without condensation)95%
Relative humidity (with condensation)Short-term condensation per Class 3K6/IEC EN 60721-3-3 and E-DIN 40046-721-3, accounting for a temperature range of ?20 ?to +60 °C (except for wind-driven precipitation, water and ice formation)
Mounting positionHorizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Mounting typeDIN-35 rail
Vibration resistance4g per IEC 60068-2-6
Shock resistance15g per IEC 60068-2-27
EMC immunity to interferenceper EN 61000-6-2, marine applications
EMC emission of interferenceper EN 61000-6-3, marine applications
Exposure to pollutantsPer IEC 60068-2-42 and IEC 60068-2-43
Fire load2.881MJ
Permissible pollutant concentration H2S at a relative humidity < 75%10ppm
Permissible pollutant concentration SO 2 at a relative humidity < 75%25ppm
eCl@ss 10.027-24-26-07
eCl@ss 9.027-24-26-07
ETIM 9.0EC000236
ETIM 8.0EC000236
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typebox
Country of originDE
GTIN4055143765565
Customs tariff number8537109160
CAS-No.1303-86-2
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)18529cd9-7cfa-40e1-86c7-4c2f413acf33
SCIP notification number (Belgium)f6127f29-8cd1-41f8-b5c0-28d665e68bf7
SCIP notification number (Bulgaria)7629d1bf-f6c9-4a83-b9af-1d4e51bc0b15
SCIP notification number (Czech Republic)169d8622-454e-4155-8fae-e0ad76e491ab
SCIP notification number (Denmark)13e3c477-7381-41a4-8419-ccbca53f6fa5
SCIP notification number (Finland)4bb6a0c7-e38b-4c7c-9bc0-f9fa2befad23
SCIP notification number (France)04b0015c-bcd7-4ba4-9617-44979af377a0
SCIP notification number (Germany)6d1b2f36-388e-4f50-b703-15ff34680c47
SCIP notification number (Hungary)ae793e32-46b8-476b-9677-d280fdb4e015
SCIP notification number (Italy)b37bc923-ef0d-4512-b5e7-5387abddaf0c
SCIP notification number (Netherlands)53f91a23-717b-4677-a000-9f671060db1a
SCIP notification number (Poland)0e23e56d-89a6-474a-80e3-cbf4de5b7688
SCIP notification number (Romania)36752548-dc6b-44c0-8fcd-4df3568d564a
SCIP notification number (Sweden)16f7e2d2-fe5b-487e-9990-29d6227f211d

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
WAGO 750-8216/025-001 Controller PFC200, 2nd Generation