Industrial Automation Parts. Prompt replies from real people.

WAGO 750-829 Controllers Bus Couplers I/O

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the WAGO 750-829?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 750-829 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
750-829
Material Number
—
Manufacturer
WAGO
Product ID
48703

Get a Free Quote

Request pricing and availability for 750-829.

More parts to source? Send your whole list in one enquiry

Key specifications

Communications
BACnet MS/TP
Supply voltage (system)
24 VDC (-25 +30 %); Via pluggable connector (CAGE CLAMP®connection)
Supply voltage (field)
24 VDC (-25 +30 %); Via power jumper contacts
Weight
168.9g
Ambient temperature (operation)
0 … +55 °C
Protection type
IP20
See all specifications

Product Highlights

  1. BACnet Controller: BACnet MS/TP communication with B-BC device profile and BACnet revision 1.7
  2. Programming and Memory: 32-bit CPU, 1024 KB program memory, 1024 KB data memory, and 32 KB non-volatile software memory, programmed via WAGO-I/O-PRO V2.3 (CODESYS V2.3)
  3. Fieldbus and Network: BACnet MS/TP transmission rates from 9600 to 115200 Bd (38400 Bd factory setting), bus segment length up to 1200 m, and ETHERNET 10/100 Mbit/s with HTTP and Web-Visu
  4. I/O Capacity: Up to 99 modules per node, 64 modules without bus extension, and a fieldbus process image of up to 1020 words input and 1020 words output
  5. Power and Isolation: 24 VDC system and field supply with 500 mA typical input current, 1700 mA total system current, 10 A power jumper contact capacity, and 500 V system/supply isolation (1500 V for BACnet MS/TP)
  6. Environmental and Mounting: DIN-35 rail mounting, IP20 protection, 0 to +55 °C operating temperature, 95% relative humidity without condensation, and 15g shock resistance per IEC 60068-2-27
750-829

Product Information

Technical Specifications

Specifications for 750-829

ParameterValue
NoteThe WAGO BACnet Configurator can be downloaded for free at www.wago.com.
CommunicationsBACnet MS/TP
ETHERNET protocolsHTTP
VisualizationWeb-Visu
CPU32 bits
Programming languages per IEC 61131-3Instruction List (IL)
Programming environmentWAGO-I/O-PROV2.3 (based on CODESYS V2.3)
Configuration optionsWAGO-I/O-CHECK
Network length (max.)limited by IEEE 802.3 specification
Transmission rateBACnet MS/TP: 38.4 kBd (9600, 19200, 38400*, 57600, 76800, 115200 Bd (per BACnet standard); * Factory setting); ETHERNET:10/100 Mbit/s
Bus segment length (max.)BACnet MS/TP: 1200 m;?Depends on baud rate/cable (per BACnet standard) 1200 m at ≤ 76800 baud; 1000 m at > 76800 baud;?ETHERNET: 100 m
Transmission medium (communication/fieldbus)ETHERNET: Twisted Pair S-UTP, STP; 100 Ω; Cat. 5e
Program memory1024 KB
Data memory1024 KB
Non-volatile software memory32Kbytes
Memory for fieldbus input variables (max.)512Byte
Memory for fieldbus output variables (max.)512Byte
Number of modules per node (max.)99
Number of modules without a bus extension (max.)64
Input and output process image (fieldbus) max.1020 Words/1020 Words
Device-specificBACnet device profile: B-BC (BACnet building controller); BACnet revision: 1.7
Powerfail RTC buffer6 days (min.)
IndicatorsLED (LINK/ACT) green: Network connection via ports 1 2; LED (MS/BT, NS) red/green: Status of node/BACnet, network; LED (I/O, USR) red/green/orange: Local data bus status, status programmable by user; LED (A, B) green: Status of system power supply, field supply
Supply voltage (system)24 VDC (-25 +30 %); Via pluggable connector (CAGE CLAMP®connection)
Input current (typ.) at nominal load (24 V)500mA
Power supply efficiency (typ.) at nominal load (24 V)90%
Current consumption (5 V system supply)450mA
Total current (system supply)1,700mA
Supply voltage (field)24 VDC (-25 +30 %); Via power jumper contacts
Current carrying capacity (power jumper contacts)10A
Number of outgoing power jumper contacts3
Isolation500 V system/supply; BACnet MS/TP: 1500 V (per BACnet standard)
WSPCert certificationin Vorbereitung
Connection technology: communication/fieldbusBACnet MS/TP:?1 x Male connector; 4-pole; modbus (TCP, UDP): 2 x RJ-45
Connection technology: system supply2 x CAGE CLAMP®
ParameterValue
Connection technology: field supply6 x CAGE CLAMP®
Connection type 1System/field supply
Solid conductor0.08 … 2.5 mm2 / 28 14 AWG
Fine-stranded conductor0.08 … 2.5 mm2 / 28 14 AWG
Strip length8 9 mm / 0.31 0.35 inches
Connection type 2Communication/fieldbus: BACnet MS/TP
Solid conductor 20.2 2.5 m㎡/ 24 12 AWG
Fine-stranded conductor 20.2 2.5 m㎡/ 24 12 AWG
Strip length 29 10 mm / 0.35 0.39 inches
Connection technology: device configuration1 x Male connector; 4-pole
Width61.5 mm / 2.421 inches
Height100 mm / 3.937 inches
Depth71.9 mm / 2.831 inches
Depth from upper-edge of DIN-rail64.7 mm / 2.547 inches
Weight168.9g
Housing materialPolycarbonate; polyamide 6.6
Conformity markingCE
Ambient temperature (operation)0 … +55 °C
Ambient temperature (storage)-25 … +85 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitudewithout temperature derating: 0 2000 m; with temperature derating: 2000 5000 m (0.5 K/100 m); 5000 m (max.)
Relative humidity (without condensation)95%
Mounting positionHorizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Mounting typeDIN-35 rail
Vibration resistanceper IEC 60068-2-6
Shock resistance15g per IEC 60068-2-27
EMC immunity to interferenceper EN 61000-6-2
EMC emission of interferenceper EN 61000-6-3
Exposure to pollutantsPer IEC 60068-2-42 and IEC 60068-2-43
Fire load2.986MJ
Permissible pollutant concentration H2S at a relative humidity < 75%10ppm
Permissible pollutant concentration SO 2 at a relative humidity < 75%25ppm
eCl@ss 10.027-24-26-07
eCl@ss 9.027-24-26-07
ETIM 9.0EC000236
ETIM 8.0EC000236
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typebox
Country of originDE
GTIN4055143235310
Customs tariff number8537109160
CAS-No.12060-00-3
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Bulgaria)e4ed94cb-c666-46e7-9f36-4aa8afba5209
SCIP notification number (Czech Republic)92245d93-5f22-4f22-8006-53bbb3a657bd

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.