Industrial Automation Parts. Prompt replies from real people.

WAGO 750-830 Controller BACnet/IP

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the WAGO 750-830?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 750-830 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
750-830
Material Number
—
Manufacturer
WAGO
Product ID
43106

Get a Free Quote

Request pricing and availability for 750-830.

More parts to source? Send your whole list in one enquiry

Key specifications

Communications
BACnet/IP
Supply voltage (system)
24 VDC (-25 +30 %); Via pluggable connector (CAGE CLAMP®connection)
Supply voltage (field)
24 VDC (-25 +30 %); Via power jumper contacts
Weight
192.4g
Ambient temperature (operation)
0 … +55 °C
Protection type
IP20
See all specifications

Product Highlights

  1. BACnet/IP Communication: Supports BACnet/IP with HTTP and Web-Visu visualization
  2. BACnet Device Profile: B-BC (BACnet building controller) per BACnet revision 1.7 and EN ISO 16484-5 / ANSI/ASHRAE 135-2004
  3. Programming: WAGO-I/O-PRO V2.3 based on CODESYS V2.3, supporting Instruction List (IL) per IEC 61131-3
  4. Configuration: WAGO-I/O-CHECK configuration options
  5. Network and Transmission: BACnet/IP transmission rate 10/100 Mbit/s, maximum bus segment length 100 m, maximum network length limited by IEEE 802.3 specification
  6. Memory: 4.5 MB internal flash, 512 KB program memory, 256 KB data memory, 24 KB non-volatile software memory, 512 Byte fieldbus input and 512 Byte fieldbus output variable memory
  7. I/O Capacity: Up to 250 modules per node, 64 modules without bus extension, input and output process image up to 1953.125 bytes each
  8. Power Supply: 24 VDC (-25 +30 %) system and field supply, 500 mA typical input current at nominal load, 87% typical efficiency, 300 mA current consumption at 5 V system supply, 1700 mA total system supply current, 10 A power jumper contact current carrying capacity, 500 V system/field isolation
  9. Connections: BACnet/IP and Modbus TCP/UDP via 1 x RJ-45 each, RS-232 serial interface via 1 x D-sub 9 socket, system supply via 2 x CAGE CLAMP, field supply via 6 x CAGE CLAMP, device configuration via 1 x 4-pole male connector
  10. Environmental and Mechanical: Operating temperature 0 to +55 °C, storage temperature -25 to +85 °C, IP20 protection, pollution degree 2 per IEC 61131-2, operating altitude up to 5000 m with derating, 95% relative humidity without condensation, DIN-35 rail mounting, 50.5 mm width, 71.1 mm height, 100 mm depth, 192.4 g weight, light gray polycarbonate/polyamide 6.6 housing
  11. Compliance: CE marking, WSPCert certification ISO 16484-5:2010, RoHS compliant with exemption 6(c), EMC immunity per EN 61000-6-2 and emission per EN 61000-6-3 for marine applications, vibration resistance per IEC 60068-2-6, shock resistance 15g per IEC 60068-2-27
750-830

Product Information

Technical Specifications

Specifications for 750-830

ParameterValue
NoteThe WAGO BACnet Configurator can be downloaded for free at www.wago.com.
CommunicationsBACnet/IP
ETHERNET protocolsHTTP
VisualizationWeb-Visu
Programming languages per IEC 61131-3Instruction List (IL)
Programming environmentWAGO-I/O-PROV2.3 (based on CODESYS V2.3)
Configuration optionsWAGO-I/O-CHECK
Network length (max.)limited by IEEE 802.3 specification
Transmission rateBACnet/IP: 10/100 Mbit/s; Serial interface: 9.6/115.2 kBd
Bus segment length (max.)BACnet/IP: 100 m;?Serial interface: 15 m
Transmission medium (communication/fieldbus)BACnet/IP:?S-UTP; 100 Ω; Cat. 5;?Serial interface:?Shielded Cu cable 2 (4) x 0.25 mm2
Internal memory (flash)4.5MB
Program memory512 KB
Data memory256 KB
Non-volatile software memory24Kbytes
Memory for fieldbus input variables (max.)512Byte
Memory for fieldbus output variables (max.)512Byte
Number of modules per node (max.)250
Number of modules without a bus extension (max.)64
Input and output process image (fieldbus) max.1953.125 bytes/1953.125 bytes
Device-specificBACnet device profile: B-BC (BACnet building controller); BACnet revision: 1.7; BACnet implementation per EN ISO 16484-5 =ANSI/ASHRAE 135-2004
IndicatorsLED (LINK/ACT) green: Network connection; LED (BT, MS, NS) red/green: Status of BACnet, node, network; LED (I/O, USR) red/green/orange: Local data bus status, status programmable by user; LED (A, B) green: System power supply status, field supply
Supply voltage (system)24 VDC (-25 +30 %); Via pluggable connector (CAGE CLAMP®connection)
Input current (typ.) at nominal load (24 V)500mA
Power supply efficiency (typ.) at nominal load (24 V)87%
Current consumption (5 V system supply)300mA
Total current (system supply)1,700mA
Supply voltage (field)24 VDC (-25 +30 %); Via power jumper contacts
Current carrying capacity (power jumper contacts)10A
Number of outgoing power jumper contacts3
Isolation500 V system/field
WSPCert certificationISO 16484-5:2010
Connection technology: communication/fieldbusBACnet/IP:?1 x RJ-45; modbus (TCP, UDP):?1 x RJ-45; RS-232 serial interface: 1 x D-sub 9 socket
Connection technology: system supply2 x CAGE CLAMP®
Connection technology: field supply6 x CAGE CLAMP®
Connection type 1System/field supply
Solid conductor0.08 … 2.5 mm2 / 28 14 AWG
Fine-stranded conductor0.08 … 2.5 mm2 / 28 14 AWG
Strip length8 9 mm / 0.31 0.35 inches
Connection technology: device configuration1 x Male connector; 4-pole
Width50.5 mm / 1.988 inches
Height71.1 mm / 2.799 inches
Depth100 mm / 3.937 inches
Weight192.4g
Colorlight gray
ParameterValue
Housing materialPolycarbonate; polyamide 6.6
Conformity markingCE
Ambient temperature (operation)0 … +55 °C
Ambient temperature (storage)-25 … +85 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitudewithout temperature derating: 0 2000 m; with temperature derating: 2000 5000 m (0.5 K/100 m); 5000 m (max.)
Relative humidity (without condensation)95%
Mounting positionHorizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Mounting typeDIN-35 rail
Vibration resistanceper IEC 60068-2-6
Shock resistance15g per IEC 60068-2-27
EMC immunity to interferenceper EN 61000-6-2, marine applications
EMC emission of interferenceper EN 61000-6-3, marine applications
Exposure to pollutantsPer IEC 60068-2-42 and IEC 60068-2-43
Fire load3.935MJ
Permissible pollutant concentration H2S at a relative humidity < 75%10ppm
Permissible pollutant concentration SO 2 at a relative humidity < 75%25ppm
Product Group15 (I/O System)
eCl@ss 10.027-24-26-07
eCl@ss 9.027-24-26-07
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typebox
Country of originDE
GTIN4045454636401
Customs tariff number8537109160
End of Sale2019-06-30
End of Production2019-07-05
End of Delivery2019-07-15
End of Service and Repair2021-06-29
CAS-No.12060-00-3
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)dd8331d2-a516-42f3-b10b-adac42811586
SCIP notification number (Belgium)35f6e720-fbb2-43fa-b766-e7880497cb65
SCIP notification number (Bulgaria)694d7bd5-6d04-47e9-8b56-1cf10d634acb
SCIP notification number (Czech Republic)d85c0b64-8196-4fb0-961f-d6fd810f9907
SCIP notification number (Denmark)2a29206b-8183-4211-b7f0-40d092ceb40f
SCIP notification number (Finland)e11d0668-bcef-4ba0-b2c9-eb11897b6f23
SCIP notification number (France)76b69654-80b0-4f17-bb6f-dc2f33f7f00e
SCIP notification number (Germany)4a09ba52-4d43-474d-9af6-2d35189c2e22
SCIP notification number (Hungary)9e1718e6-382e-44df-b70e-a8dada131d2c
SCIP notification number (Italy)a1aefffe-549c-4994-b659-14d27bc5a5a7
SCIP notification number (Netherlands)a58ade70-5c7c-4b49-b696-7b744eb26b5c
SCIP notification number (Poland)6c7ac4ee-ce30-4c94-aad3-edfb56347796
SCIP notification number (Romania)7e67b2b8-de28-4d7b-83c6-6b5a93c9d025
SCIP notification number (Sweden)f7fb0133-70f0-4dc1-9e49-a9ef3473181f

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp