- 855-8001
WAGO 855-8001 signal conditioner for voltage measurement, mounted on insulated round cable via IDC connection. Accepts solid or fine-stranded conductors from 2.5 to 6 mm² (14 to 10 AWG). Rated voltage AC 400 V; maximum continuous current 2 A; voltage drop ≤ 0.5 VAC. Voltage path fuse: 2 A, 450 V, F, 70 kA, 5 x 25 mm (WAGO 855-8020). Rated surge voltage 6 kV, overvoltage category III, pollution degree 2, protection type IP20. Test voltage AC 3 kV at 50 Hz for 1 min. Secondary side cable: 1 x 1.0 mm² flexible with ferrule, 3 m length. Dimensions 23 x 59 x 23 mm; weight 25.9 g; PA 66 housing. Ambient temperature -5 to +55 °C operation, -20 to +70 °C storage. Conforms to EN 60947-7-1; CE marked.
- 855-8002
WAGO 855-8002 voltage tap for voltage measurement on insulated round cable. Rated voltage AC 400 V, maximum continuous current 2 A, voltage drop ≤ 0.5 VAC, no fuse in the voltage path. IDC connection accepts solid and fine-stranded conductors of 2.5–6 mm² (14–10 AWG). Secondary side: 1 x 1.0 mm² flexible cable with ferrule, 3 m length. Dimensions 23 x 50 x 23 mm; weight 20 g; PA 66 housing; IP20; mounting on insulated round cable; torque 1.5–2 Nm; reusable up to 24 times. Rated surge voltage 6 kV, overvoltage category III, pollution degree 2. Test voltage AC 3 kV, 50 Hz, 1 min. Operating temperature -5 to +55 °C; storage -20 to +70 °C; relative humidity 5–85% without condensation; maximum operating altitude 2000 m. Conforms to EN 60947-7-1; CE marking.
- 855-8003
WAGO 855-8003 signal conditioner, a voltage tapping terminal with fuse for phase application. It mounts on insulated round cable and uses IDC connection for solid or fine-stranded conductors of 10–16 mm² (8–6 AWG). Rated voltage is AC 400 V; maximum continuous current is 2 A. The voltage-path fuse is 2 A, 450 V, F, 70 kA, 5 x 25 mm (WAGO 855-8020). Voltage drop is ≤ 0.5 VAC. Rated surge voltage is 6 kV, overvoltage category III, pollution degree 2. Test voltage is AC 3 kV, 50 Hz, 1 min. Protection type IP20. Dimensions: 23 mm width, 59 mm height, 23 mm depth; weight 72.6 g. Operating ambient temperature -5 to +55 °C. Standards: EN 60947-7-1; CE marking.
- 855-8004
WAGO 855-8004 voltage tap for voltage measurement, mounted on insulated round cable. Rated voltage AC 400 V; maximum continuous current 2 A; voltage drop ≤ 0.5 VAC. No fuse in the voltage path. Connection technology is IDC; accepts solid and fine-stranded conductors of 10–16 mm² (8–6 AWG). Secondary side: 1 x 1.0 mm² flexible cable with ferrule, 3 m length. Rated surge voltage 6 kV, overvoltage category III, pollution degree 2, protection type IP20. Test voltage AC 3 kV at 50 Hz for 1 min. Dimensions 23 x 50 x 23 mm; PA 66 housing; 21 g. Torque range 1.5–2 Nm. Reusable up to 24 times. Ambient temperature -5 to +55 °C in operation, -20 to +70 °C in storage; relative humidity 5–85 % without condensation; maximum operating altitude 2000 m. Conforms to EN 60947-7-1; CE marking.
- 855-8008
WAGO 855-8008 busbar tap for measuring L- or N-conductors, with an integrated SIBA fuse. It mounts on a busbar and uses Push-in CAGE CLAMP connection technology (WAGO 2624 Series). Dimensions are 61 mm width, 14 mm height, and 48 mm depth; weight is 31 g. The voltage path fuse is 2 A, 450 V, F, 70 kA, 5 x 25 mm (WAGO 855-8020). Rated voltage is AC 400 V; measured variable is voltage. Solid and fine-stranded conductors accept 0.2 to 6 mm2 (24 to 10 AWG), with 10 to 12 mm strip length. Operating ambient temperature is -25 to +70 °C, storage -40 to 85 °C, relative humidity 5 to 85 percent without condensation, and maximum operating altitude 2000 m. Standard: IEC 60947-7-3.
- 855-801/2000-1001
WAGO 855-801/2000-1001 is a closed current transformer with a 2000 A primary rated current and 1 A secondary rated current, rated power 10 VA, accuracy class 1, and rated frequency 50 to 60 Hz. The measurement conductor feedthrough is Ø 55 mm. Rated continuous thermal current is 1.2 x IN; rated short-time thermal current is 60 x IN/1 s (max. 100 kA/1 s). Test voltage is AC 6 kV at 50 Hz for 1 min, and highest voltage for equipment Um is AC 1.2 kVrms. Insulation class E. Dimensions are 120 mm width, 134.4 mm height, and 52 mm depth; weight 396 g. Operation is -5 to +50 °C, storage -25 to +70 °C, maximum operating altitude 1000 m. Connection technology is CAGE CLAMP. Conformity marking CE; standards/specifications EN 61869-1.
- 855-8015
WAGO 855-8015 power tap for busbar installation, with clamping connection and integrated SIBA fuse with indicator for measuring L- or N-conductors. It measures voltage, has a rated voltage of AC 400 V, and uses Push-in CAGE CLAMP connection technology with a WAGO 2624 Series connector. Busbar thickness range is 4 mm to 15 mm. Dimensions are 79 mm width, 15 mm height, and 72 mm depth, weighing 160 g. Operating ambient temperature is -25 to +70 °C; storage temperature is -40 to 85 °C. Relative humidity is 5 to 85 % without condensation. Maximum operating altitude is 2000 m. The voltage path fuse is 2 A; 450 V; F; 70 kA; 5 x 25 mm (WAGO 855-8020). Standards/specifications: IEC 60947-7-3.
- 855-805/2000-1001
WAGO 855-805/2000-1001 is a closed current transformer for current measurement, with a 2000 A / 5 A ratio, 5 A secondary rated current, 10 VA rated power, and accuracy class 1. The feedthrough for the measurement conductor is Ø 55 mm. It measures 120 mm wide, 134.4 mm high, and 52 mm deep, and weighs 396 g. Rated frequency is 50 … 60 Hz. Rated continuous thermal current Icth is 1.2 x IN; rated short-time thermal current Ith is 60 x IN / 1 s (max. 100 kA / 1 s). Test voltage is AC 6 kV; 50 Hz; 1 min. Highest voltage for equipment Um is AC 1.2 kVrms. Insulation class E. Ambient temperature: -5 … +50 °C operation, -25 … +70 °C storage. Maximum operating altitude 1000 m. Connection technology is CAGE CLAMP. Conformity marking CE; standards/specifications EN 61869-1.