- 855-8008
WAGO 855-8008 busbar tap for measuring L- or N-conductors, with an integrated SIBA fuse. It mounts on a busbar and uses Push-in CAGE CLAMP connection technology (WAGO 2624 Series). Dimensions are 61 mm width, 14 mm height, and 48 mm depth; weight is 31 g. The voltage path fuse is 2 A, 450 V, F, 70 kA, 5 x 25 mm (WAGO 855-8020). Rated voltage is AC 400 V; measured variable is voltage. Solid and fine-stranded conductors accept 0.2 to 6 mm2 (24 to 10 AWG), with 10 to 12 mm strip length. Operating ambient temperature is -25 to +70 °C, storage -40 to 85 °C, relative humidity 5 to 85 percent without condensation, and maximum operating altitude 2000 m. Standard: IEC 60947-7-3.
- 855-801/2000-1001
WAGO 855-801/2000-1001 is a closed current transformer with a 2000 A primary rated current and 1 A secondary rated current, rated power 10 VA, accuracy class 1, and rated frequency 50 to 60 Hz. The measurement conductor feedthrough is Ø 55 mm. Rated continuous thermal current is 1.2 x IN; rated short-time thermal current is 60 x IN/1 s (max. 100 kA/1 s). Test voltage is AC 6 kV at 50 Hz for 1 min, and highest voltage for equipment Um is AC 1.2 kVrms. Insulation class E. Dimensions are 120 mm width, 134.4 mm height, and 52 mm depth; weight 396 g. Operation is -5 to +50 °C, storage -25 to +70 °C, maximum operating altitude 1000 m. Connection technology is CAGE CLAMP. Conformity marking CE; standards/specifications EN 61869-1.
- 855-8015
WAGO 855-8015 power tap for busbar installation, with clamping connection and integrated SIBA fuse with indicator for measuring L- or N-conductors. It measures voltage, has a rated voltage of AC 400 V, and uses Push-in CAGE CLAMP connection technology with a WAGO 2624 Series connector. Busbar thickness range is 4 mm to 15 mm. Dimensions are 79 mm width, 15 mm height, and 72 mm depth, weighing 160 g. Operating ambient temperature is -25 to +70 °C; storage temperature is -40 to 85 °C. Relative humidity is 5 to 85 % without condensation. Maximum operating altitude is 2000 m. The voltage path fuse is 2 A; 450 V; F; 70 kA; 5 x 25 mm (WAGO 855-8020). Standards/specifications: IEC 60947-7-3.
- 855-805/2000-1001
WAGO 855-805/2000-1001 is a closed current transformer for current measurement, with a 2000 A / 5 A ratio, 5 A secondary rated current, 10 VA rated power, and accuracy class 1. The feedthrough for the measurement conductor is Ø 55 mm. It measures 120 mm wide, 134.4 mm high, and 52 mm deep, and weighs 396 g. Rated frequency is 50 … 60 Hz. Rated continuous thermal current Icth is 1.2 x IN; rated short-time thermal current Ith is 60 x IN / 1 s (max. 100 kA / 1 s). Test voltage is AC 6 kV; 50 Hz; 1 min. Highest voltage for equipment Um is AC 1.2 kVrms. Insulation class E. Ambient temperature: -5 … +50 °C operation, -25 … +70 °C storage. Maximum operating altitude 1000 m. Connection technology is CAGE CLAMP. Conformity marking CE; standards/specifications EN 61869-1.
- 855-9150/2000-1251
WAGO 855-9150/2000-1251 is a split-core Rogowski coil current transformer for current measurement. It measures 10 A to 10,000 A, or up to 4000 A when combined with recommended WAGO products, with a sensitivity of 22.5 mV/kA at 50 Hz and accuracy class 0.5. Rated frequency is 50 to 60 Hz. The feedthrough for the measurement conductor is 125 mm, cable length is 1.5 m, and weight is 130 g. Rated voltage is 1000 VACrms (Cat. III) or 600 VACrms (Cat. IV). Protection type is IP57. Operating ambient temperature is -40 to +80 °C at up to 90% relative humidity without condensation, maximum operating altitude 2000 m. Conforms to EN 61010-1 and carries the CE marking.
- 855-9150/2000-1751
WAGO 855-9150/2000-1751 signal conditioner with Rogowski coil technology, measuring current from 10 A to 10,000 A (up to 4000 A when combined with recommended WAGO products). Rated voltage is 1000 VACrms (Cat. III) or 600 VACrms (Cat. IV), with 12.8 kV impulse withstand voltage (1.2/50 µs) and isolation test at AC 7.4 kV, 50 Hz, 1 min. Rated frequency 50 to 60 Hz; sensitivity 22.5 mV/kA at 50 Hz; internal resistance 105 Ω; limit frequency 350 kHz; accuracy class 0.5. Split-core, suspended mounting with 175 mm feedthrough and 1.5 m cable. IP57, 130 g, operating -40 to +80 °C, ≤ 90% relative humidity without condensation, max altitude 2000 m. Conforms to EN 61010-1; CE marked.
- 855-9150/2000-701
WAGO 855-9150/2000-701 Rogowski coil signal conditioner for current measurement. Rogowski technology measures a primary current range of 10 A to 10,000 A without saturation effects; up to 4000 A when combined with recommended WAGO products. Rated voltage is 1000 VACrms (Cat. III) or 600 VACrms (Cat. IV), with 12.8 kV impulse withstand voltage (1.2/50 µs) and isolation test at AC 7.4 kV, 50 Hz, 1 min. Accuracy class 0.5; sensitivity 22.5 mV/kA at 50 Hz; rated frequency 50 to 60 Hz; limit frequency 420 kHz; mutual inductance 71.98 nH; internal resistance 56 Ω; maximum output signal 30 V. Rated short-time thermal current Ith is 300 kA at 50 Hz. Split-core, suspended mounting with 70 mm conductor feedthrough and 1.5 m cable. IP57; 130 g; operating ambient -40 to +80 °C; relative humidity ≤ 90% without condensation; maximum operating altitude 2000 m. Conforms to EN 61010-1; CE marking.
- 855-9450/2000-701
WAGO 855-9450/2000-701 is a split-core Rogowski current transformer for current measurement. Measurement range is 10 A to 10,000 A, or up to 4000 A in combination with recommended WAGO products. Rated frequency is 50 to 60 Hz; sensitivity is 22.5 mV/kA at 50 Hz; limit frequency is 344 kHz; accuracy class 0.5. The 70 mm feedthrough accepts a measurement conductor, and the 4.5 m cable ends in wire leads. Rated voltage is 1000 VACrms (Cat. III) or 600 VACrms (Cat. IV). Rated short-time thermal current Ith is 300 kA at 50 Hz. Protection type is IP57. Ambient temperature range is -40 to +80 °C. Standards/specifications: EN 61010-1.