- 857-424
WAGO 857-424 signal conditioner/isolation amplifier for analog signals. Inputs: 0–5 V (voltage) and 0–10 mA (current); outputs: 2–10 V and 0–10 mA. Input resistance is ≤100 kΩ for voltage input and ≤50 Ω for current input; maximum input voltage 30 V, maximum input current 50 mA. Limit frequency is configurable via DIP switch at 100 Hz or 1 kHz, with typical step response 5.2 ms at 100 Hz and 650 µs at 1 kHz. Typical transmission error is ≤0.1 % of upper-range value; temperature coefficient ≤0.01 %/K. Supply is 24 VDC (SELV), current consumption <27 mA default. Test voltage input/analog output 1/analog output 2/supply: 3 kVAC, 50–60 Hz, 1 min. Reinforced insulation (safe isolation). 6 mm wide, DIN-35 rail mounting. Use shielded signal lines.
- 857-450
WAGO 857-450 signal conditioner, loop-powered via the output circuit. Input accepts ±1 V or ±5 mA; output is 4–20 mA with a maximum load impedance of 600 Ω. Supply voltage is DC 8–30 V, derived from the output circuit. Configuration is via DIP switch, with a limit frequency of 100 Hz or 30 Hz selectable by DIP switch. Typical step response is 3.5 ms; transmission error is ≤0.1 % of upper-range value; temperature coefficient is ≤0.01 %/K. Test voltage input/output/supply is AC 2.5 kV at 50 Hz for 1 min. Connections use Push-in CAGE CLAMP® for solid conductors 0.08–2.5 mm² (28–14 AWG) and fine-stranded conductors 0.34–2.5 mm² (22–14 AWG), strip length 9–10 mm. DIN-35 rail mounting, 6 mm wide, IP20, operating temperature -25 to +70 °C.
- 857-451
WAGO 857-451 passive signal conditioner for 1-channel current isolation. Input and output are both 0–20 mA; maximum input current 40 mA and maximum input voltage 20 V. The response threshold is 200 μA, limit frequency 100 Hz, and typical step response 3.5 ms. Transmission error is ≤ 0.1 % of upper-range value, load error ≤ 0.05 % per 100 Ω load, and temperature coefficient ≤ 0.01 %/K. The current output permits load impedance ≤ 600 Ω, with possible temperature range restrictions; voltage drop is ≤ 2.5 V at 20 mA. Power is supplied passively via the input. Reinforced insulation provides safe isolation between input and analog output; test voltage is AC 3 kV, 50 Hz, 1 min. Rated voltage 300 V; measurement category CAT II (input); overvoltage category II; pollution degree 2; protection type IP20. Use shielded signal lines. Outputs must not be left open.
- 857-452
WAGO 857-452 passive signal isolator for current signals, 2-channel, powered via the input. Input and output are 0–20 mA; maximum input current 40 mA, maximum input voltage 20 V, response threshold 200 µA. Load impedance for the current output is ≤ 600 Ω, with possible temperature range restrictions. Voltage drop is ≤ 2.5 V at 20 mA (output). Limit frequency is 100 Hz and typical step response is 3.5 ms. Typical transmission error is ≤ 0.1 % of upper-range value; load error ≤ 0.05 % per 100 Ω load; temperature coefficient ≤ 0.01 %/K. Rated voltage 300 V; measurement category CAT II (input) per EN/UL 61010-2-030; overvoltage category II; pollution degree 2; IP20. Connection is Push-in CAGE CLAMP®. Outputs must not be left open.
- 857-500
WAGO 857-500 signal conditioner converts frequency signals to current or voltage outputs. It accepts frequency generators, NAMUR sensors per DIN EN 50227, and NPN/PNP transistor outputs without pull-up or pull-down resistors. Frequency ranges are 0.1 Hz to 120 kHz, 0.1 Hz to 1 kHz, and 0.1 Hz to 20 kHz respectively. Configuration is via DIP switch. Outputs are 0 to 5 V and 0 to 10 mA. Supply is DC 24 V with ±30 % tolerance and current consumption ≤ 40 mA. Transmission error is ≤ 0.1 % of upper-range value; temperature coefficient ≤ 0.01 %/K. The 6 mm wide module mounts on DIN-35 rail, uses Push-in CAGE CLAMP® connections, and operates from -25 to +70 °C.
- 857-531
The WAGO 857-531 is a DIN-35 rail-mounted signal conditioner with a voltage input of ±10 V and a current input of ±20 mA. Input resistance is ≤100 kΩ for voltage and ≤200 Ω for current; maximum input is 31 V or 22 mA. It provides one changeover relay contact and one adjustable digital switching threshold. Configuration is via DIP switch or WAGO Interface Configuration Software or App. Supply is 24 VDC (SELV), ±30%, drawing ≤25 mA plus digital output current. Dimensions are 6 mm wide, 94 mm high, and 97.8 mm deep from the DIN-rail upper edge. Push-in CAGE CLAMP® connections accept 0.08–2.5 mm² (28–14 AWG) solid and 0.34–2.5 mm² (22–14 AWG) fine-stranded conductors, strip length 9–10 mm. Operation is -25 to +70 °C at up to 2000 m, IP20.
- 857-551
WAGO 857-551 signal conditioner for current input (AC/DC 0–5 A, IN 1) with current and voltage outputs (0–10 mA, 0–5 V) plus a digital output. Measurement range 0 to 6 A can only be set using the WAGO Interface Configuration Software. Supply voltage is DC 24 V (SELV), ±30%, with current consumption ≤50 mA. Rated voltage 300 V; measurement category CAT II (input 300 VAC) per EN 61010-2-030. Push-in CAGE CLAMP® connections accept 0.08–2.5 mm² (28–14 AWG) solid and 0.34–2.5 mm² (22–14 AWG) fine-stranded conductors, strip length 9–10 mm. DIN-35 rail mounting, 6 mm wide, IP20, operating temperature -40 to +70 °C at nominal current. Standards: EN 61010-1; EMC EN 61000-6-2, EN 61000-6-3, EN 61326-1.
- 857-552
WAGO 857-552 signal conditioner for Rogowski coils, converting voltage input to current or voltage output. Input is AC 10.05 mV (RC1); sensitivity RC2B 22.5 mV/kA. Measurement range AC 500 A (RC1), AC 2000 A (RC2A), AC 4000 A (RC2B). Frequency range 50 Hz for sinusoidal signals; limit frequency 2 kHz. Outputs 0–5 V (load ≤ 1 kΩ) and 0–10 mA (load ≤ 600 Ω). Supply DC 24 V, ±30%, consumption ≤ 40 mA. One adjustable switching threshold; continuous DO current max. 100 mA. Push-in CAGE CLAMP connection, 6 mm wide, DIN-35 rail mounting, IP20, operating temperature -25 to +70 °C. Settings via DIP switch or WAGO Interface Configuration Software/App.